L3 Campus Stackable Managed Switch

Spesifikasi

  • Model: Omada Campus Stackable L3 Managed Switch
  • Front Panel: Mode Selection Button, Management Port, LED,
    Console Port USB2.0 Port (Type-C/RJ45), 1G RJ45 Port, 10G SFP+ Slot
    LED
  • Petunjuk LED:
    • PWR1*: Green On (switch powered by PWR1), Off (PWR2
      disconnected or not working properly)
    • PWR2: Green On (switch powered by PWR1 and PWR2 connected),
      Yellow On** (PWR2 powered), Off (PWR1 disconnected or not working
      betul)
    • LED SYS FAN: Green On (all fans work properly), Yellow On (not
      all fans work properly)
    • MGMT: On (device linked to port), Flashing (transmitting or
      receiving data), Off (no device linked to port)
    • MST: On (device linked to port), Flashing (transmitting or
      receiving data), Off (no device linked to port)

Arahan Penggunaan Produk

Bab 2: Pemasangan

Sebelum memulakan proses pemasangan, pastikan anda mempunyai semua
the necessary tools and follow safety precautions.

  • Kandungan Pakej: Check all items mentioned in
    bungkusan itu.
  • Langkah Keselamatan: Ikut garis panduan untuk
    memastikan pemasangan selamat.
  • Alat Pemasangan: Gather all tools required
    untuk pemasangan.
  • Pemasangan Produk: Ikuti langkah demi langkah
    instructions provided in the manual for successful
    pemasangan.

Bab 3: Sambungan

After installation, connect the switch to the network using
appropriate cables and ports as per your network setup.

Bab 4: Konfigurasi

Configure the switch based on your requirements. You can choose
between Standalone Mode or Controller Mode as per your network
keperluan.

Soalan Lazim

Q: What should I do if the LED indications show an error?

A: If the LED indications suggest improper functioning, check
the power sources and connections. Refer to the troubleshooting
bahagian dalam manual untuk bantuan selanjutnya.

“`

Penyelesaian Rangkaian Perniagaan
Panduan Pemasangan
Omada Campus Stackable L3 Managed Switch

Mengenai Panduan Pemasangan ini
Panduan Pemasangan ini menerangkan ciri perkakasan, kaedah pemasangan dan perkara-perkara yang perlu diberi perhatian semasa pemasangan. Panduan Pemasangan ini berstruktur seperti berikut: Bab 1 Pengenalan Bab ini menerangkan komponen luaran suis. Bab 2 Pemasangan Bab ini menggambarkan cara memasang suis. Bab 3 Sambungan Bab ini menggambarkan cara melakukan sambungan fizikal suis. Bab 4 Konfigurasi Bab ini menggambarkan cara mengkonfigurasi suis. Lampiran A Penyelesaian Masalah Lampiran B Spesifikasi

Penonton

Panduan Pemasangan ini adalah untuk:

Jurutera Rangkaian

Pentadbir Rangkaian

Konvensyen
· Sesetengah model yang dipaparkan dalam panduan ini mungkin tidak tersedia di negara atau wilayah anda. Untuk maklumat jualan tempatan, lawati https://www.omadanetworks.com/.
· Angka dalam Bab 2, Bab 3, dan Bab 4 adalah untuk tujuan demonstrasi sahaja. Suis anda mungkin berbeza dalam rupa daripada yang digambarkan.
· Pengiraan bajet PoE adalah berdasarkan ujian makmal. Bajet kuasa PoE sebenar tidak dijamin dan akan berbeza-beza akibat batasan pelanggan dan faktor persekitaran.
· Panduan ini menggunakan format khusus untuk menyerlahkan mesej khas. Jadual berikut menyenaraikan ikon notis yang digunakan sepanjang panduan ini.

Ingatkan berhati-hati. Perhatian menunjukkan potensi yang boleh mengakibatkan kerosakan peranti.
Ingatkan untuk mengambil perhatian. Catatan mengandungi maklumat berguna untuk penggunaan produk dengan lebih baik.

Dokumen Berkaitan
Panduan Pengguna dan Panduan Rujukan CLI produk disediakan di Pusat Muat turun. Untuk mendapatkan maklumat produk terkini, lawati pejabat webtapak: https://support.omadanetworks.com/document/.

kandungan
Bab 1 Pengenalan ———————- 01
1.1 Produk Selesaiview ………………………………………………………..01 1.2 Rupa…………………………………………………………………..01
Bab 2 Pemasangan ———————- 12
2.1 Kandungan Pakej ……………………………………………………….12 2.2 Langkah Berjaga-jaga Keselamatan ………………………………………………………12 2.3 Alat Pemasangan ……………………………………………..14 2.4 Pemasangan Produk ……………………………………………..14
Bab 3 Sambungan ———————- 22
3.1 Ethernet Port …………………………………………………………..22 3.2 10G SFP+/25G SFP28/100G QSFP28 Slot ………..22 3.3 Console Port ……………………………………………………………22 3.4 Verify Installation…………………………………………………….23 3.5 Power On ………………………………………………………………….24 3.6 Initialization………………………………………………………………24 3.7 Stack Topology ……………………………………………………….24
Bab 4 Konfigurasi ——————– 27
4.1 Konfigurasi Selesaiview…………………………………27 4.2 Mod Kendiri……………………………………………………27 4.3 Mod Pengawal……………… ……………………………………………28
Lampiran A Penyelesaian Masalah —————- 32
Lampiran B Spesifikasi —————— 33

Omada Campus Stackable L3 Managed Switch

Bab 1 Pengenalan

1.1 Produk Selesaiview
Direka untuk perusahaan dan campus, Omada Campus Stackable L3 Managed Switch provides wire-speed performance and abundant L2 and L3 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. Static Routing, RIP, OSPF, BGP, IS-IS, PIM-SM/DM/SSM, and ECMP come with abundant Layer 3 routing protocols that support a scalable network. Physically stacking for builtin redundancy and performance. Redundant power supplies and fans make it an ideal choice for reliable networking architecture. VRRP allows a group of switches to dynamically back up each other. ERPS supports rapid protection and recovery in a ring topology. MACsec, secure boot, ACL, 802.1x and Dynamic ARP Inspection provide robust security strategies. QoS and IGMP snooping/filtering optimize voice and video application. Link aggregation (LACP) increases aggregated bandwidth, optimizing the transport of business critical data. SNMP, RMON, WEB, Netconf and CLI Log-in bring abundant management policies. These switches integrate multiple functions with excellent performance, and is friendly to manage, which can fully meet the need of the users demanding higher networking performance. S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is also a Power Sourcing Equipment (PSE*). The RJ45 ports that support Power over Ethernet (PoE*) function can automatically detect and supply power to those powered devices (PDs*) complying with IEEE 802.3af, IEEE 802.3at, and IEEE 802.3bt (only for S6500-24MPP4Y/S6500-48MPP6Y). *PSE: a device (switch or hub for instance) that provides power through an Ethernet cable. *PoE: This technology describes a system to transmit electrical power, along with data, to remote devices over standard twisted-pair cable in an Ethernet. *PD: a device powered by a PSE and thus consumes energy. Examptermasuk membekalkan kamera rangkaian, titik capaian LAN wayarles, telefon IP, hab rangkaian, komputer terbenam dsb.
1.2 Penampilan
Front Panel (The figure is for demonstration only. It may differ from your actual product. )
The front panel of S6500-24G4XF is shown as the following figure.
Butang Pemilihan Mod
Pelabuhan Pengurusan

LED

Port Konsol Port USB2.0 (Jenis-C/RJ45)

Port RJ1 45G

10G SFP+ Slot LED

The front panel of S6500-48G6XF is shown as the following figure.
Butang Pemilihan Mod
Pelabuhan Pengurusan

LED

Port Konsol Port USB2.0 (Jenis-C/RJ45)

Port RJ1 45G

10G SFP+ Slot LED

Pengenalan 01

Omada Campus Stackable L3 Managed Switch

Petunjuk LED

PWR1*

PWR2

Hijau Hidup

Mati

Hijau Hidup

Kuning Hidup**

Mati

Hijau Hidup

Mati

Mati

Petunjuk
Suis dikuasakan oleh PWR1. PWR2 diputuskan atau ia berfungsi dengan tidak betul.
Suis dikuasakan oleh PWR1. PWR1 dan PWR2 disambungkan.*
Suis dikuasakan oleh PWR2. PWR1 diputuskan atau ia berfungsi dengan tidak betul.
Suis dimatikan atau kedua-dua PWR1 dan PWR2 berfungsi dengan tidak betul.

LED SYS FAN
MGMT
MST
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(Apabila LED SPEED dihidupkan)
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(Apabila LED STK dihidupkan)
Port 25-28 of S6500-24G4XF/ Port 49-54 of S6500-48G6XF ***

Petunjuk
Berkelip: Suis berfungsi dengan betul. Hidup atau Mati: Suis berfungsi dengan tidak betul.
Hijau Hidup: Semua peminat berfungsi dengan betul. Kuning Hidup: Tidak semua peminat berfungsi dengan betul.
Hidup: Peranti dipautkan ke port. Berkelip: Menghantar atau menerima data. Mati: Tiada peranti dipautkan ke port.
Hidup: Peranti berfungsi sebagai suis induk dalam topologi tindanan atau ia berfungsi secara individu. Mati: Peranti berfungsi sebagai suis ahli dalam topologi tindanan.
Hijau Hidup: Berjalan pada 1000 Mbps, tetapi tiada aktiviti. Berkelip Hijau: Berjalan pada 1000 Mbps dan menghantar atau menerima data. Kuning Hidup: Berjalan pada 10Mbps/100 Mbps, tetapi tiada aktiviti. Berkelip Kuning: Berjalan pada 10Mbps/100 Mbps dan menghantar atau menerima data. Mati: Tiada peranti dipautkan ke port yang sepadan.
Hidup: Nombor port menunjukkan ID unit dalam topologi tindanan.
Hijau Hidup: Berjalan pada 10 Gbps, tetapi tiada aktiviti. Berkelip Hijau: Berjalan pada 10 Gbps dan menghantar atau menerima data. Kuning Hidup: Berjalan pada 1 Gbps, tetapi tiada aktiviti. Berkelip Kuning: Berjalan pada 1 Gbps dan menghantar atau menerima data. Mati: Tiada peranti dipautkan ke port yang sepadan.

*PWR1 is the primary power supply and it takes priority over PWR2. When the device is powered by PWR1, PWR2 will be working in the backup mode.
**Apabila kedua-dua PWR1 dan PWR2 berfungsi dengan betul dan suis dikuasakan oleh PWR1, ia mengambil masa 10-20 saat untuk LED PWR2 (kuning) padam selepas PWR2 dicabut.
***All 10 Gbps SFP+ slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.

02 Pengenalan

Omada Campus Stackable L3 Managed Switch The front panel of S6500-24GP4XF is shown as the following figure.

Butang Pemilihan Mod
Pelabuhan Pengurusan
Port Konsol LED Port USB2.0 (Jenis-C/RJ45)

Port RJ1 45G

10G SFP+ Slot LED

Panel hadapan S6500-48GP6XF ditunjukkan seperti rajah berikut.

Butang Pemilihan Mod
Pelabuhan Pengurusan
Port Konsol LED Port USB2.0 (Jenis-C/RJ45)

Port RJ1 45G

10G SFP+ Slot LED

The front panel of S6500-24M4Y is shown as the following figure.

Butang Pemilihan Mod
Pelabuhan Pengurusan
Port Konsol LED Port USB2.0 (Jenis-C/RJ45)

Port RJ2.5 45G

25G SFP28 Slot LED

The front panel of S6500-24MPP4Y is shown as the following figure.

Butang Pemilihan Mod
Pelabuhan Pengurusan
Port Konsol LED Port USB2.0 (Jenis-C/RJ45)

Port RJ2.5 45G

25G SFP28 Slot LED

Pengenalan 03

Omada Campus Stackable L3 Managed Switch The front panel of S6500-48M6Y is shown as the following figure.

Butang Pemilihan Mod
Pelabuhan Pengurusan

Port Konsol LED Port USB2.0 (Jenis-C/RJ45)

Port RJ2.5 45G

The front panel of S6500-48MPP6Y is shown as the following figure.

25G SFP28 Slot LED

Butang Pemilihan Mod
Pelabuhan Pengurusan
Port Konsol LED Port USB2.0 (Jenis-C/RJ45)

Port RJ2.5 45G

25G SFP28 Slot LED

LED Indication LED
PWR1* PWR2
SYS FAN PoE MAX
(For S6500-24GP4XF, S6500-48GP6XF, S6500-24MPP4Y, S6500-48MPP6Y)
MGMT
MST

Petunjuk
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Berkelip: Suis berfungsi dengan betul. Hidup atau Mati: Suis berfungsi dengan tidak betul.
Hijau Hidup: Semua peminat berfungsi dengan betul. Kuning Hidup: Tidak semua peminat berfungsi dengan betul.
Hidup: Baki kuasa PoE ialah 7 W. Berkelip: Baki kuasa PoE mengekalkan 7 W selepas LED ini dihidupkan selama 2 minit. Mati: Baki kuasa PoE ialah > 7 W.
Hidup: Peranti dipautkan ke port. Berkelip: Menghantar atau menerima data. Mati: Tiada peranti dipautkan ke port.
Hidup: Peranti berfungsi sebagai suis induk dalam topologi tindanan atau ia berfungsi secara individu. Mati: Peranti berfungsi sebagai suis ahli dalam topologi tindanan.

04 Pengenalan

Omada Campus Stackable L3 Managed Switch

LED

Petunjuk

Port 1-24 of S6500-24GP4XF/
Port 1-48 of S6500-48GP6XF
(Apabila LED SPEED dihidupkan)

Hijau Hidup: Berjalan pada 1000 Mbps, tetapi tiada aktiviti. Berkelip Hijau: Berjalan pada 1000 Mbps dan menghantar atau menerima data. Kuning Hidup: Berjalan pada 10Mbps/100 Mbps, tetapi tiada aktiviti. Berkelip Kuning: Berjalan pada 10Mbps/100 Mbps dan menghantar atau menerima data. Mati: Tiada peranti dipautkan ke port yang sepadan.

Port 1-24 of S6500-24M4Y & S6500-24MPP4Y/
Port 1-48 of S6500-48M6Y & S6500-48MPP6Y
(Apabila LED SPEED dihidupkan)

Green On: Running at 2.5 Gbps, but no activity. Green Flashing: Running at 2.5 Gbps and transmitting or receiving data. Yellow On: Running at 10 Mbps/100 Mbps/1000 Mbps, but no activity. Yellow Flashing: Running at 10 Mbps/100 Mbps/1000 Mbps and transmitting or receiving data. Off: No device is linked to the corresponding port.

Port 1-24 of S6500-24GP4XF, S6500-24M4Y &
S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF, S6500-48M6Y &
S6500-48MPP6Y
(Apabila LED STK dihidupkan)

Hidup: Nombor port menunjukkan ID unit dalam topologi tindanan.

Port 1-24 of S6500-24GP4XF & S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF & S6500-48MPP6Y
(Apabila LED PoE dihidupkan)

Green On: The port is supplying power normally. Green Flashing: The supply power exceeds the correponding port’s maximum power. Yellow On: Overload or short circuit is detected. Off: Not providing PoE power on the port

Port 25-28 of S6500-24GP4XF/ Port 49-54 of S6500-48GP6XF ***

Hijau Hidup: Berjalan pada 10 Gbps, tetapi tiada aktiviti. Berkelip Hijau: Berjalan pada 10 Gbps dan menghantar atau menerima data. Kuning Hidup: Berjalan pada 1 Gbps, tetapi tiada aktiviti. Berkelip Kuning: Berjalan pada 1 Gbps dan menghantar atau menerima data. Mati: Tiada peranti dipautkan ke port yang sepadan.

Port 25-28 of S6500-24M4Y & S6500-24MPP4Y/
Port 49-54 of S6500-48M6Y & S6500-48MPP6Y***

Hijau Hidup: Berjalan pada 25 Gbps, tetapi tiada aktiviti. Berkelip Hijau: Berjalan pada 25 Gbps dan menghantar atau menerima data. Kuning Hidup: Berjalan pada 1 Gbps/10 Gbps, tetapi tiada aktiviti. Berkelip Kuning: Berjalan pada 1 Gbps/10 Gbps dan menghantar atau menerima data. Mati: Tiada peranti dipautkan ke port yang sepadan.

*By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, S6500-24M4Y/S650048M6Y is shipped with a PSM550-AC power supply module, and S6500-48GP6XF/S6500-24MPP4Y/ S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately.
**By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode: for S6500-24GP4XF/S6500-48GP6XF/S650024MPP4Y/S6500-48MPP6Y, you can specify the primary power supply and the backup power supply according to your needs; for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
***All 10 Gbps SFP+ slots and 25 Gbps SFP28 slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.

Pengenalan 05

Omada Campus Stackable L3 Managed Switch The front panel of S7500-26XF6Y is shown as the following figure.
Pelabuhan Pengurusan

LED

Port Konsol Port USB3.0

(RJ45/Jenis-C)

Pemilihan Mod

Butang

10G SFP+ Slot (Port 1-26)

The front panel of S7500-48XF4C is shown as the following figure.

LED 25G SFP28 Slot (Port 27-32)

Butang Pemilihan Mod
Pelabuhan Pengurusan
Port Konsol LED Port USB3.0 (Jenis-C/RJ45)

10G SFP+ Slot (Port 1-48)

The front panel of S7500-24Y4C is shown as the following figure.

100G QSFP28 Slot LED (Port 49-52)

Pelabuhan Pengurusan

LED

Port USB3.0

Pelabuhan Konsol

(RJ45/Jenis-C)

Butang Pemilihan Mod

Slot SFP25 28G

LED

(Port 1-24)

The front panel of S7500-48Y8C is shown as the following figure.

Slot QSFP100 28G (Port 25-28)

LED Mode Selection Button

25G SFP28 Slot (Port 1-48)

06 Pengenalan

Slot QSFP100 28G (Port 49-56)

Omada Campus Stackable L3 Managed Switch The front panel of S7500-32C is shown as the following figure.

Butang Pemilihan Mod
LED Port Pengurusan
Port USB3.0

Console Port (Type-C/RJ45)

Slot 100G QSFP28

LED

Note: S7500-24Y4C and S7500-48Y8C are designed for installation in Network Telecommunications Facilities (NTFs) where ambient temperature and humidity are controlled.

LED Indication LED
PWR1* PWR2
SYS FAN
MGMT
MST
Port 1-26 of S7500-26XF6Y/ Port 1-48 of S7500-48XF4C
(Apabila LED SPD dihidupkan)
Port 1-24 of S7500-24Y4C/ Port 1-48 of S7500-48Y8C
(When the SPD/SPEED LED is on)

Petunjuk
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Berkelip: Suis berfungsi dengan betul. Hidup atau Mati: Suis berfungsi dengan tidak betul.
Hijau: Semua peminat berfungsi dengan baik. Kuning: Tidak semua peminat berfungsi dengan baik.
Hidup: Peranti dipautkan ke port. Berkelip: Menghantar atau menerima data. Mati: Tiada peranti dipautkan ke port.
Nota:
For S7500-48Y8C, this LED lights green at 1 Gbps and orange at sub-1 Gbps.
Hidup: Peranti berfungsi sebagai suis induk dalam topologi tindanan atau ia berfungsi secara individu. Mati: Peranti berfungsi sebagai suis ahli dalam topologi tindanan.
Hijau Hidup: Berjalan pada 10 Gbps, tetapi tiada aktiviti. Berkelip Hijau: Berjalan pada 10 Gbps dan menghantar atau menerima data. Kuning Hidup: Berjalan pada 1 Gbps, tetapi tiada aktiviti. Berkelip Kuning: Berjalan pada 1 Gbps dan menghantar atau menerima data. Mati: Tiada peranti dipautkan ke port yang sepadan.
Hijau Hidup: Berjalan pada 25 Gbps, tetapi tiada aktiviti. Berkelip Hijau: Berjalan pada 25 Gbps dan menghantar atau menerima data. Kuning Hidup: Berjalan pada 1 Gbps/10 Gbps, tetapi tiada aktiviti. Berkelip Kuning: Berjalan pada 1 Gbps/10 Gbps dan menghantar atau menerima data. Mati: Tiada peranti dipautkan ke port yang sepadan.

Pengenalan 07

Omada Campus Stackable L3 Managed Switch

LED

Petunjuk

Port 27-32 of S7500-26XF6Y ***
(Apabila LED SPD dihidupkan)

Hijau Hidup: Berjalan pada 25 Gbps, tetapi tiada aktiviti. Berkelip Hijau: Berjalan pada 25 Gbps dan menghantar atau menerima data. Kuning Hidup: Berjalan pada 1 Gbps/10 Gbps, tetapi tiada aktiviti. Berkelip Kuning: Berjalan pada 1 Gbps/10 Gbps dan menghantar atau menerima data. Mati: Tiada peranti dipautkan ke port yang sepadan.

Port 49-52 of S7500-48XF4C/
Port 25-28 of S7500-24Y4C/ Port 49-56 of S7500-48Y8C/ Port 1-32 of S7500-32C***
(When the SPD/SPEED LED is on)

Hijau Hidup: Berjalan pada 100 Gbps, tetapi tiada aktiviti. Berkelip Hijau: Berjalan pada 100 Gbps dan menghantar atau menerima data. Kuning Hidup: Berjalan pada 40 Gbps, tetapi tiada aktiviti. Berkelip Kuning: Berjalan pada 40 Gbps dan menghantar atau menerima data. Mati: Tiada peranti dipautkan ke port yang sepadan.
Nota:
For S7500-48XF4C/S7500-48Y8C/S7500-32C, the indication above applies only when the 100 Gbps QSFP28 slots work with common cables. When the slots work with 1-to-4 breakout cables, a single slot is split into four 25 Gbps interfaces. In such scenario, the LED will light green only when all four interfaces are working at 25 Gbps (maximum speed), otherwise it will light yellow. When no device is connected to any of the four interfaces, the LED will be off. (The 100 Gbps QSFP28 slots will support 1-to-4 breakout cables in a future software release.)

Port 1-32 of S7500-26XF6Y/
Port 1-48 of S7500-48XF4C/ Port 1-28 of S7500-24Y4C/ Port 1-56 of S7500-48Y8C
(Apabila LED STK dihidupkan)

Hidup: Nombor port menunjukkan ID unit dalam topologi tindanan.

*By default, S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with a PSM550-AC power supply module installed respectively. One more power supply module needs to be purchased separately. **By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply. ***All 25 Gbps SFP28 slots of S7500-26XF6Y and 100 Gbps QSFP28 slots of S7500-48XF4C/S7500-24Y4C/ S7500-48Y8C/S7500-32C can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Port Introduction (The Management Port, Console Ports, and USB Ports of S7500-48Y8C are located on the rear panel.)
Port Pengurusan Direka untuk menyambung peranti untuk pengurusan melalui web, CLI or SNMP. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. Console Port Designed to connect with a computer for monitoring and configuring the switch. When the switch has an RJ45 console port and a Type-C console port, console input is active on only one console port at a time. By default, the Type-C connector takes priority over the RJ45 connector, or you can change the priority through the web. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. USB Port Designed to install the USB flash disk for data storage. 1000M RJ45 Port Designed to connect to the device with a bandwidth of 10Mbps, 100 Mbps or 1000 Mbps. For PoE switches, the port can also provide power for PDs.

08 Pengenalan

Omada Campus Stackable L3 Managed Switch
2.5G RJ45 Port Designed to connect to the device with a bandwidth of 10 Mbps, 100 Mbps, 1000 Mbps or 2.5 Gbps. For PoE switches, the port can also provide power for PDs. 10G SFP+ Slot Designed to install the 10 Gbps/1 Gbps optical module. 25G SFP28 Slot Designed to install the 25 Gbps/10 Gbps/1 Gbps optical module. 100G QSFP28 Slot Designed to install the 100 Gbps/40 Gbps optical module. Port Feature

Model

1000M

2.5G 10G SFP+ 25G SFP28 100G QSFP28 Management Console USB

RJ45 Port RJ45 Port Slot

Slot

Slot

Pelabuhan

Pelabuhan Pelabuhan

S6500-24G4XF

24

/

4

/

/

S6500-48G6XF

48

/

6

/

/

S6500-24GP4XF

24

/

4

/

/

S6500-48GP6XF

48

/

6

/

/

S6500-24M4Y

/

24

/

4

/

S6500-24MPP4Y

/

24

/

4

/

S6500-48M6Y

/

48

/

6

/

S6500-48MPP6Y

/

48

/

6

/

S7500-26XF6Y

/

/

26

6

/

S7500-48XF4C

/

/

48

/

4

S7500-24Y4C

/

/

/

24

4

S7500-48Y8C

/

/

/

48

8

S7500-32C

/

/

/

/

32

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

Rear Panel (The figure is for demonstration only. It may differ from your actual product. )
The rear panel of S6500-24G4XF/S6500-48G6XF is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Kensington Security Slot Grounding Terminal Power Socket

Locking Strap Slot

Nota: PWR1 ialah bekalan kuasa utama dan ia mengambil keutamaan berbanding PWR2.

Pengenalan 09

Omada Campus Stackable L3 Managed Switch
The rear panel of S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Slot Keselamatan Kensington

LED

Terminal Pembumian

Modul Bekalan Kuasa

LED

Locking Strap Slot

Note: By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, and S650048GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately. Both PWR 1 and PWR2 can work simultaneously, or you can specify the primary power supply and the backup power supply according to your needs. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Terminal Pembumian

LED

Power Supply Module Locking Strap Slot

LED

Slot Keselamatan Kensington

Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode: for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply; for S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C, you can specify the primary power supply and the backup power supply according to your needs; Generally, the primary power supply takes priority over the backup power supply.

Panel belakang S7500-48Y8C ditunjukkan seperti rajah berikut. Angka tersebut adalah untuk tujuan demonstrasi sahaja. Suis anda mungkin berbeza dalam penampilan daripada yang digambarkan.

Terminal Pembumian

LED

LED

Tali Mengunci

Slot

Modul Bekalan Kuasa

10 Pengenalan

ManagemeC(nTtoyPnposeor-tCle/RPJoU4rt5S)B3P.o0wPeorrSt upplyLoMcokdiSnulgoletStraLpED

Omada Campus Stackable L3 Managed Switch
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S7500-32C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

LED LED
Locking Strap Slot
Modul Bekalan Kuasa Slot Keselamatan Kensington

Terminal Pembumian

LED
Locking Strap Slot

Modul Bekalan Kuasa

Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
Power Supply Module The pluggable power supply module PSM500-AC/PSM900-AC/PSM550-AC is an AC-input power supply module. It can convert the input voltage to 53.5 V (12 V for PSM550-AC) with the maximum output power of 500 W/900 W/550 W respectively. Kensington Security Slot Secure the lock (not provided) into the security slot to prevent the device from being stolen.
Grounding Terminal The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed lightning protection measures, refer to the Lightning Protection Guide from: https://support.omadanetworks.com/r/1004/. Locking Strap Slot Remove the instruction label and insert the AC power cable locking strap into the slot to secure the power cable.

Pengenalan 11

Omada Campus Stackable L3 Managed Switch

Bab 2 Pemasangan

2.1 Kandungan Pakej

Pastikan pakej mengandungi item berikut. Sila hubungi pengedar anda, jika mana-mana item tersenarai rosak atau hilang. Angka-angka adalah untuk demonstrasi sahaja. Item sebenar mungkin berbeza dalam rupa dan kuantiti daripada yang digambarkan.

Tukar

Kord Kuasa dan Kabel Konsol

Panduan Pemasangan
Penyelesaian Rangkaian Perniagaan
Panduan Pemasangan
Omada Campus Stackable L3 Managed Switch

Pendakap Lekap, Skru dan Kaki Getah

2.2 Langkah Keselamatan
Untuk mengelakkan sebarang kerosakan peranti dan kecederaan badan yang disebabkan oleh penggunaan yang tidak betul, anda harus mematuhi peraturan berikut.
Langkah Berjaga-jaga Keselamatan Pastikan kuasa padam semasa pemasangan. Pakai tali pergelangan tangan pencegahan ESD, dan pastikan tali pergelangan tangan mempunyai sentuhan kulit yang baik dan
berasas dengan baik. Gunakan hanya kord kuasa yang disediakan bersama suis. Pastikan bahawa bekalan voltage sepadan dengan spesifikasi yang ditunjukkan pada panel belakang
suis. Pastikan suis dipasang dalam persekitaran yang mempunyai pengudaraan yang baik dan lubang pengudaraannya tidak dipasang
disekat. Jangan buka atau tanggalkan penutup suis. Sebelum membersihkan peranti, potong bekalan kuasa. Jangan bersihkannya dengan kain berair, dan jangan sekali-kali
use any other liquid cleaning method. Place the device with its bottom surface facing downwards. Only instructed person or skilled person can be allowed to install, replace, or service this device.
Keperluan Tapak
Suhu/Kelembapan

12 Pemasangan

Omada Campus Stackable L3 Managed Switch Keep the equipment room at an appropriate level of temperature and humidity. Too much or too little humidity may lead to bad insulation, leakage of electricity, mechanical property changes, and corrosion. High temperatures may accelerate aging of the insulation materials, significantly shortening the service life of the device. To find out the best temperature and humidity conditions for the device, check the Appendix B Specifications. Clearness
Debu yang terkumpul pada suis boleh diserap oleh elektrik statik dan mengakibatkan sentuhan yang lemah pada titik sentuhan logam. Beberapa langkah telah diambil untuk peranti menghalang elektrik statik, tetapi elektrik statik yang terlalu kuat boleh menyebabkan kerosakan maut pada unsur elektronik pada papan litar dalaman. Untuk mengelakkan kesan elektrik statik pada operasi suis, letakkan kepentingan yang tinggi pada item berikut: Habuk peranti dengan kerap, dan pastikan udara dalaman bersih. Pastikan peranti dibumikan dengan baik dan pastikan elektrik statik telah dipindahkan. Gangguan Elektromagnet
Elemen elektronik termasuk kemuatan dan kearuhan pada peranti boleh dipengaruhi oleh gangguan luar, seperti pelepasan yang dikendalikan oleh gandingan kapasitans, gandingan induktans dan gandingan galangan. Untuk mengurangkan gangguan, pastikan anda mengambil langkah berikut: Gunakan bekalan kuasa yang boleh menapis gangguan secara berkesan daripada grid kuasa. Jauhkan peranti daripada peranti frekuensi tinggi dan arus kuat seperti pemancar radio
stesen. Gunakan perisai elektromagnet apabila perlu. Perlindungan Kilat
Pemasangan 13

Omada Campus Stackable L3 Managed Switch
vol yang sangat tinggitagarus boleh dihasilkan serta-merta apabila kilat berlaku dan udara dalam laluan nyahcas elektrik boleh dipanaskan serta-merta sehingga 20,000 °C. Memandangkan arus segera ini cukup kuat untuk merosakkan peranti elektronik, langkah perlindungan kilat yang lebih berkesan harus diambil. Pastikan rak dan peranti dibumikan dengan baik. Pastikan soket kuasa mempunyai sentuhan yang baik dengan tanah. Simpan sistem kabel yang munasabah dan elakkan kilat teraruh. Gunakan isyarat SPD (Surge Protective Device) apabila pendawaian luar.
Nota: Untuk langkah perlindungan kilat terperinci, rujuk Panduan Perlindungan Kilat dari: https://support.omadanetworks.com/r/1004/. Tapak Pemasangan
Apabila memasang peranti pada rak atau meja kerja rata, pentingkan perkara berikut: Pasang peranti dengan permukaan bawahnya menghadap ke bawah sahaja. Peralatan ini tidak sesuai digunakan di lokasi yang berkemungkinan terdapat kanak-kanak. Rak atau meja kerja adalah rata, stabil dan cukup kukuh untuk menyokong berat sekurang-kurangnya 9.5 kg. Rak atau meja kerja mempunyai sistem pengudaraan yang baik. Bilik peralatan mempunyai pengudaraan yang baik. Rak dibumikan dengan baik. Jauhkan peranti kurang daripada 1.5 meter dari soket kuasa.
2.3 Alatan Pemasangan
Pemutar skru Phillips pemutar pergelangan tangan ESD
Nota: Alat ini tidak disertakan dengan produk kami. Jika perlu, anda boleh membelinya secara berasingan.
2.4 Pemasangan Produk
Suis direka bentuk dengan ciri pelesapan haba depan ke belakang. Apabila ia berfungsi, udara beredar seperti yang ditunjukkan di bawah. Untuk pelesapan haba yang lebih baik, sila pasang peranti dalam persekitaran yang mempunyai pengudaraan yang baik dan biarkan 5 hingga 10 cm jurang di sekeliling peranti.
14 Pemasangan

Rajah 2-1

Peredaran Udara

Omada Campus Stackable L3 Managed Switch

Pemasangan Desktop

Untuk memasang peranti pada desktop, ikut langkah:
1. Pasang peranti pada permukaan rata yang cukup kuat untuk menyokong keseluruhan berat peranti dengan semua kelengkapan.

2. Keluarkan kertas penyokong pelekat dari kaki getah.

3. Pasangkan kaki getah ke bahagian bawah peranti untuk mengelakkannya daripada tergelincir apabila diletakkan pada desktop.

Rajah 2-2

Pemasangan Desktop

Kaki Bahagian Bawah Takik Peranti

Pemasangan Rak

Pakej ini termasuk 6 pasang kurungan pemasangan rak yang berbeza, gambar mereka digambarkan di bawah dan mungkin berbeza daripada produk sebenar.

Rajah 2-3

Kurung Pemasangan

Kumpulan Lubang Skru 2

Bracket D Bracket C Bracket B Bracket A

Kumpulan Lubang Skru 1
Kumpulan Lubang Skru 3

Kurungan F

Screw Hole Group 4-2 (for device with 420mm depth)

Kumpulan Lubang Skru 5

Lubang Skru

Kumpulan 4-1

Screw Hole Group 4-3

(for device with 380mm depth)

(for device with

460mm depth)

Kurungan E

Pemasangan 15

Omada Campus Stackable L3 Managed Switch

Before installing the device in an EIA standard-sized, 19-inch rack, please check the efficiency of the grounding system and the stability of the rack, then wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded. Bracket B, C & E have two adjustable ears, please measure the distance between the front-post rack and the rear-post rack, and determine a suitable mounting method from below:

Kaedah

Demonstrasi

Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket B (Ear towards back)

Jarak Rak
(Untuk peranti dengan kedalaman 380mm)

Jarak Rak
(Untuk peranti dengan kedalaman 420mm)

Jarak Rak
(Untuk peranti dengan kedalaman 460mm)

498-640mm 538-680mm 578-720mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket C (Ear towards back)

477-498mm 517-538mm 557-578mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards back)

429-477mm 469-517mm 509-557mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards front)

410-429mm 450-469mm 490-509mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 3) + Bracket C (Ear towards back)

357-410mm 397-450mm 437-490mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket B (Ear towards back)

282-410mm 322-450mm 362-490mm

16 Pemasangan

Omada Campus Stackable L3 Managed Switch

Front: Bracket A Rear: Bracket F (Screw Hole Group 4) + Bracket E (Ear towards back)

555-936mm 555-936mm 555-936mm

Front: Bracket A Rear: Bracket F (Screw Hole Group 5) + Bracket E (Ear towards back)

743-1121mm 743-1121mm 743-1121mm

Untuk memasang peranti, ikut arahan yang diterangkan di bawah:

1. Pasang kacang M6 pada rak.

Rajah 2-4

Mengamankan Kacang M6

×8

2. Attach the mounting brackets (B, C or E) to the rear-post racks and secure them with the provided M6 screws, as illustrated in the following figure.

Rajah 2-5

Memasang Kurungan pada Rak

or

3. Attach the brackets A & D/F to the switch with the provided M3 screws.

Pemasangan 17

Omada Campus Stackable L3 Managed Switch

Rajah 2-6

Memasang Kurungan pada Suis

4. After the brackets are attached to the device, hold the switch with attached brackets up until it aligns with the brackets on the racks, and gently push the switch backwards until it is in place, then secure the device on the racks with M6 screws and fix brackets B/C or E to brackets D or F with M4 screws on both sides.

Rajah 2-7

Memasang Suis pada Rak

Caution: Leave 5 to 10 cm gaps around the devices for air circulation. Avoid placing heavy things on the device. Mount devices in the order demonstrated above and ensure a certain clearance between devices for
the purpose of heat dissipation.

18 Pemasangan

Omada Campus Stackable L3 Managed Switch

Pemasangan Modul Bekalan Kuasa

S6500-24GP4XF is shipped with a PSM500-AC power supply module installed, S6500-48GP6XF/ S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module installed, and S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S750032C is shipped with a PSM550-AC power supply module installed. It looks like below, and the image may differ from your actual product.

Rajah 2-8

Penampilan Modul Bekalan Kuasa

Penyambung Kord Kuasa AC
FAN

Klip Penahan

Pemegang Pengekstrakan

LED

Locking Strap Slot Release Handle

Jika anda perlu menambah satu lagi modul bekalan kuasa, sila ikut langkah:

1. Pakai tali pergelangan tangan pencegahan ESD, dan pastikan ia mempunyai sentuhan kulit yang baik dan dibumikan dengan baik.

2. Tekan pemegang pengekstrakan modul dengan satu tangan, dan pegang bahagian bawah modul menggunakan tangan anda yang lain. Tolak modul masuk perlahan-lahan di sepanjang rel panduan slot.

3. Lepaskan pemegang pengekstrakan untuk memasang modul bekalan kuasa di tempatnya.

Rajah 2-9

Memasang Modul Bekalan Kuasa

Pemegang Pelepas

Caution: Do not plug the power cord until the power supply module installation is completed. When installing a power supply module, make sure it is set correctly in the operation of installation. Do not use too much force in the installation. If resistance is encountered or positions of the power
supply module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the power supply module is not installed properly. Please check carefully.
The power supply module is designed with a locking strap slot. If you need to secure the power cable with the included locking strap, please follow the steps:
1. Pakai tali pergelangan tangan pencegahan ESD, dan pastikan ia mempunyai sentuhan kulit yang baik dan dibumikan dengan baik.
Pemasangan 19

Omada Campus Stackable L3 Managed Switch
2. Remove the instruction label on the AC power cable locking strap slot. 3. Attach the clamp to the AC power cable and insert the locking strap into the slot. 4. Adjust tightness and distance of the locking strap using clips to ensure the cable is securely fastened.
Figure 2-10 Installing the Locking Strap

Jika anda perlu mengalih keluar modul bekalan kuasa, sila ikuti langkah-langkah:
1. Pakai tali pergelangan tangan pencegahan ESD, dan pastikan ia mempunyai sentuhan kulit yang baik dan dibumikan dengan baik.
2. Depress the retainer clip to release the locking strap, and then remove the power cord from the external power supply system and the power module.
3. Press the extraction handle of the module with one hand, and pull the extraction handle using your other hand, until the module completely comes out of the chassis.
Caution: Unplug the power cord first, then remove the power supply module. When removing a power supply module, make sure that the power supply module is set correctly in the
operation of installation. In order to better protect the power supply module during removal, it is recommended that you
package it in an antistatic bag.
Pemasangan Modul Kipas
S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S650048MPP6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with hot-swappable fan modules installed. They look like below, and the images may differ from your actual product.
Rajah 2-11 Kemunculan Modul Kipas
LED

20 Pemasangan

Extraction Handle Retainer Clips Release Handle

Omada Campus Stackable L3 Managed Switch For normal operation of the switch, please ensure that models with 5 fan modules maintain at least 4 operational modules, while models with 4 fan modules maintain at least 3 operational modules. If one fan module is damaged, please replace it as follows: 1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well
dibumikan. 2. Tekan pemegang pengekstrakan modul dengan satu tangan, dan tarik pemegang pengekstrakan sehingga
modul terkeluar sepenuhnya dari casis.
Rajah 2-12 Mengeluarkan Modul Kipas Yang Rosak
3. Tekan pemegang pengekstrakan modul kipas baharu dengan satu tangan, dan pegang bahagian bawah modul menggunakan tangan anda yang lain. Tolak modul masuk perlahan-lahan di sepanjang rel panduan slot.
4. Release the extraction handle to fix the power supply module in place. Caution: S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S6500-48MPP6Y/ S7500-26XF6Y uses hot-swappable fan modules with a maximum speed of 9,000 RPM. S7500-48XF4C/ S7500-24Y4C/S7500-48Y8C/S7500-32C uses hot-swappable fan modules with a maximum speed of 18,000 RPM. Please do not interchange or mix fan modules between models. Sharp edges on the fan module may cause injury, so please operate with caution. Make sure the damaged fan module is in place before you are going to replace it. DO NOT unplug the damaged fan module until the replacement operation. Do not use too much force in the replacement. If resistance is encountered or positions of the fan module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the fan module is not installed properly. Please check carefully.
Pemasangan 21

Omada Campus Stackable L3 Managed Switch

Bab 3 Sambungan

3.1 Port Ethernet

Sambungkan port Ethernet suis ke komputer dengan kabel RJ45 seperti ditunjukkan dalam gambar berikut.

Rajah 3-1

Menyambungkan Port RJ45

Pelabuhan RJ45

Kabel RJ45

3.2 10G SFP+/25G SFP28/100G QSFP28 Slot

The following figure demonstrates the connection of 10G SFP+/25G SFP28/100G QSFP28 slot to an optical module

Rajah 3-2

Inserting the Fiber Module

Slot Fiber Module

3.3 Pelabuhan Konsol
CLI (Antara Muka Talian Perintah) membolehkan anda mengurus suis, dengan itu anda boleh memuatkan CLI selepas menyambungkan PC atau Terminal ke port konsol pada suis melalui kabel (kabel konsol RJ45 disediakan, manakala kabel Jenis-C tidak disediakan)
Sambungkan port konsol RJ45 peranti dengan komputer anda melalui kabel konsol seperti yang ditunjukkan oleh rajah berikut.

22 Sambungan

Rajah 3-3

Menyambung Port Konsol (RJ45).

Omada Campus Stackable L3 Managed Switch

Sambungkan port konsol Jenis-C peranti dengan komputer anda dengan kabel Jenis-C (tidak disediakan) seperti yang ditunjukkan oleh rajah berikut.

Rajah 3-4

Menyambung Port Konsol (USB).

Note: RJ45 console port and Type-C console port cannot be used concurrently. Type-C Console port takes
priority over the RJ45 console port. The Type-C console port is hot-pluggable while the RJ45 console port is not. Keep the device power
off when plugging the console cable into the RJ45 console port. Do not connect the console port with other ports by RJ45 cable.
3.4 Mengesahkan Pemasangan
Selepas melengkapkan pemasangan, sahkan perkara berikut: Perlu ada kelegaan 5 hingga 10 cm di sekeliling peranti untuk pengudaraan dan pastikan aliran udara
adalah memadai. voltage bekalan kuasa memenuhi keperluan vol inputtage peranti. Soket kuasa, peranti dan rak dibumikan dengan baik. Peranti disambungkan dengan betul ke peranti rangkaian lain.
Sambungan 23

Omada Campus Stackable L3 Managed Switch

3.5 Hidupkan

Palamkan penyambung wanita kord kuasa yang disediakan ke dalam soket kuasa peranti dan palamkan penyambung positif ke dalam salur keluar kuasa seperti yang ditunjukkan oleh rajah berikut. Pastikan bahawa voltage bekalan kuasa memenuhi keperluan vol inputtage (100-240 V~ 50/60 Hz).

Rajah 3-5

Menyambung ke Bekalan Kuasa

Note: The figure is to illustrate the application and principle. The provided plug and module in your region
may differ from the figures above. Generally PWR1 takes priority over PWR2.

3.6 Permulaan
Setelah peranti dihidupkan, ia akan memulakan Ujian Kendiri Power-On. Satu siri ujian dijalankan secara automatik untuk memastikan peranti berfungsi dengan baik. Selama ini, indikator LEDnya akan bertindak balas dalam urutan berikut:
1. Petunjuk LED PWR menyala sepanjang masa. LED SYS dan penunjuk LED dari semua port tidak berfungsi.
2. Selepas kira-kira satu minit, penunjuk LED SYS dan LED semua port akan berkelip seketika dan kemudian dimatikan.
3. Beberapa saat kemudian, indikator LED SYS akan berkelip, yang menunjukkan permulaan yang berjaya.
3.7 Topologi Timbunan
With stackable design, the switches can be stacked into one stack topology for higher reliability, larger bandwidth, and simpler networking. To build the stack topology, you need to prepare 2-12 switches and enough 10G SFP+/25G SFP28/100G QSFP28 modules/cables. For more details, see the table below:

Tukar

Model Serasi

Kuantiti

S6500-24G4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48G6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24GP4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48GP6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24M4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y S6500-24MPP4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)

24 Sambungan

Omada Campus Stackable L3 Managed Switch

S6500-48M6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

S6500-48MPP6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

S7500-26XF6Y S7500-26XF6Y

S7500-48XF4C S7500-48XF4C

S7500-24Y4C S7500-24Y4C

S7500-48Y8C S7500-48Y8C

S7500-32C

S7500-32C

2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)

Terdapat tiga struktur topologi tindanan untuk senario yang berbeza, sila bina topologi yang betul mengikut keperluan anda:

1. Topologi Rantaian: Topologi rantaian agak mudah dan tidak memerlukan sambungan kabel antara unit pertama dan terakhir. Ia sesuai untuk susun jarak jauh, tetapi kebolehpercayaannya agak rendah.

Rajah 3-6

Topologi Rantaian

Kumpulan Pelabuhan Susun 2
Kumpulan Pelabuhan Susun 1

2. Topologi Cincin: Topologi cincin mempunyai kebolehpercayaan yang lebih tinggi berbanding dengan topologi rantai. Apabila salah satu rantai dalam topologi cincin diputuskan, topologi cincin menjadi topologi rantai, tetapi keseluruhan sistem tindanan masih boleh berfungsi seperti biasa. Topologi gelang memerlukan sambungan kabel antara unit pertama dan terakhir, jadi ia tidak sesuai untuk tindanan jarak jauh.

Rajah 3-7

Topologi Cincin

Kumpulan Pelabuhan Susun 2

Kumpulan Pelabuhan Susun 1

Sambungan 25

Omada Campus Stackable L3 Managed Switch

3. Topologi Bintang: Topologi bintang menghubungkan suis ke suis utama pusat, oleh itu, ia boleh meningkatkan kadar penghantaran data dengan ketara antara suis ahli sambil menyediakan pengurusan bersatu.

Rajah 3-8

Topologi Bintang

Kumpulan Pelabuhan Susun 2

Kumpulan Pelabuhan Susun 3

Kumpulan Pelabuhan Susun 1

Note: The stacking port is not allowed to connect to non-stacking port, as it may affect the operation of the
device. Stacking ports with the same group ID are not allowed to connect to stacking ports with different
group IDs, neither to different devices. A stacking port group is a logical port dedicated to stacking and needs to be bound to a stacking port.
A stacking port group can be bound to one or more stacking ports to improve bandwidth and reliability.

26 Sambungan

Omada Campus Stackable L3 Managed Switch

Bab 4 Konfigurasi

4.1 Konfigurasi Selesaiview
Suis menyokong dua pilihan konfigurasi:
Mod Kendiri: Konfigurasikan dan urus suis secara bersendirian. Mod Pengawal: Konfigurasikan dan urus peranti rangkaian secara berpusat. Ia disyorkan dalam
rangkaian berskala besar, yang terdiri daripada peranti massa seperti titik akses, suis dan pintu masuk.
Catatan: Apabila suis diubah dari Standalone Mode ke Controller Mode, konfigurasi suis akan hilang. Untuk perincian, rujuk dokumen berkaitan di pusat muat turun rasmi kami webtapak: https://support.omadanetworks.com/product/.

4.2 Mod Kendiri

Dalam Mod Kendiri, gunakan komputer untuk mengkonfigurasi dan mengurus suis menggunakan GUI (Antara Muka Pengguna Grafik) atau CLI (antara muka baris arahan).

Rajah 4-1

Topologi untuk Mod Kendiri

Tukar

PC

Menggunakan GUI
1. Untuk mengakses halaman pengurusan suis, pastikan suis dan komputer berada di subnet yang sama. Buka penyemak imbas dan ketik alamat IP suis di medan alamat, kemudian tekan kekunci Enter.
Jika suis memperoleh alamat IP daripada pelayan DHCP (biasanya get laluan), cari alamat IP suis pada pelayan DHCP.
Sekiranya tidak, gunakan alamat IP lalai 192.168.0.1 untuk melancarkan halaman pengurusan suis.

2. Kali pertama anda log masuk, tetapkan nama pengguna dan kata laluan untuk melindungi rangkaian dan peranti anda dengan lebih baik. Selepas itu, sistem akan mengubah hala anda kembali ke antara muka log masuk secara automatik untuk mengesahkan dengan kelayakan yang baru dibuat.

3. Setelah berjaya masuk, halaman utama akan muncul. Anda boleh mengklik menu di bahagian atas dan kiri untuk mengkonfigurasi fungsi yang sesuai.
Untuk konfigurasi terperinci, rujuk Panduan Pengguna dan Panduan CLI. Panduan boleh didapati di pusat muat turun rasmi kami webtapak: https://support.omadanetworks.com/product/.
Menggunakan CLI Sediakan sambungan Telnet atau SSH untuk mengakses suis melalui CLI.

Konfigurasi 27

Omada Campus Stackable L3 Managed Switch

Gunakan port konsol untuk mengakses suis. Apabila menggunakan port konsol, mulakan program emulasi terminal (seperti Hyper Terminal) pada PC dan konfigurasikan program emulasi terminal seperti berikut:

Kadar Baud 38400 bps

Bit Data 8

Pariti Tiada

Bit Berhenti 1

Kawalan Aliran Tiada

Untuk konfigurasi terperinci, rujuk Panduan Pengguna dan Panduan CLI. Panduan boleh didapati di pusat muat turun rasmi kami webtapak: https://support.omadanetworks.com/product/.
Note: You may need to change the password the first time you log in, which will better protect your network and devices.

4.3 Mod Pengawal
Controller Mode applies to the large scale network with mass devices. All devices can be centrally configured and monitored via Omada Pro Hardware Controller (C5300), Omada Pro Software Controller, or Omada Pro Cloud-Based Controller.
Note: Before the following configurations, make sure the switch can access the internet. When using Omada Pro Hardware/Software/Cloud-based Controller, make sure the switch and the controller are in the same subnet. Typically, the switch obtains IP address from the DHCP server. You can check the switch’s IP address on the DHCP server.

Via Omada Pro Hardware Controller (C5300)

Omada Pro Hardware Controller (C5300) is a good alternative if you have no spare PC to keep running Omada Pro Software Controller in the network. It needs to be purchased additionally. Follow the steps below to configure the Omada Pro Hardware Controller (C5300).

Rajah 4-2

Manage the network via Omada Pro Hardware Controller (C5300)

Suis Gerbang

Omada Pro Hardware Controller (C5300) EAP
28 Konfigurasi

EAP

EAP

Pelanggan

Omada Campus Stackable L3 Managed Switch

Note: Before you start, be sure to power up and connect your devices according to the topology figure. A DHCP server (typically a gateway with DHCP function enabled) is required to assign IP addresses to
the EAPs and clients in your local network. Omada Pro Controller must have network access to some Omada campus devices (the gateway,
switch, or APs) in order to find, adopt, and manage them.

1. Cari alamat IP get laluan. Buka baris arahan pada PC anda dan masukkan ipconfig. Dalam senarai hasil, cari Gerbang Lalai, yang juga merupakan alamat IP get laluan.
2. Pelancaran a web pelayar dan masukkan alamat IP get laluan. Log masuk ke pintu masuk web muka surat. Kemudian pergi ke Rangkaian > LAN > Senarai Klien DHCP untuk mencari alamat IP pengawal anda mengikut alamat MACnya.
3. Masukkan alamat IP pengawal anda dalam bar alamat untuk membukanya web muka surat.
4. Pada Pengawal Omada Pro web halaman, ikut wizard untuk melengkapkan persediaan pantas.
5. Setelah persediaan cepat, halaman log masuk muncul. Masukkan nama pengguna dan kata laluan yang telah anda buat dan klik Log masuk. Kemudian anda boleh mengkonfigurasi pengawal lebih jauh.
6. Jika anda ingin mengurus peranti secara jarak jauh, ikut langkah seterusnya:
a. Pastikan Cloud Access didayakan pada pengawal anda. Secara lalai, Cloud Access didayakan. Pastikan LED Awan berkelip perlahan.

b. Pelancaran a web pelayar dan masukkan https://omada.tplinkcloud.com dalam bar alamat. Masukkan ID dan kata laluan TP-Link anda untuk log masuk. Klik + Tambah Pengawal dan pilih Pengawal Perkakasan untuk menambah pengawal anda. Kemudian anda boleh mengkonfigurasi lagi pengawal.

For more details, refer to the Installation Guide of C5300.

Melalui Pengawal Perisian Omada Pro

Download the Omada Pro Software Controller on a PC with Windows OS or Linux OS. Then run the file and follow the wizard to install the Omada Pro Software Controller. Follow the steps below to configure the Controller.

Rajah 4-3

Urus rangkaian melalui Pengawal Perisian Omada Pro

Gerbang

Tukar

Pengawal

AP Pengawal Perisian Omada Pro

AP

AP

berjalan di PC Host

Pelanggan

Konfigurasi 29

Omada Campus Stackable L3 Managed Switch

1. Launch the Omada Pro Software Controller on your PC. After the initiation process, the controller automatically opens its web muka surat. Jika tidak, klik Lancarkan Penyemak Imbas untuk Mengurus Rangkaian.
2. Pada Pengawal Omada Pro web halaman, ikut wizard untuk melengkapkan persediaan pantas.
3. Setelah persediaan cepat, halaman log masuk muncul. Masukkan nama pengguna dan kata laluan yang telah anda buat dan klik Log masuk. Kemudian anda boleh mengkonfigurasi pengawal lebih jauh.
4. Jika anda ingin mengurus peranti secara jarak jauh, ikut langkah seterusnya:
a. Make sure that Cloud Access is enabled on your controller and your controller has been bound with your TP-Link ID. On the Omada Pro Controller’s web halaman, pergi ke Tetapan > Akses Awan untuk mendayakan Akses Awan dan ikat ID TP-Link anda. Jika anda telah menyediakannya dalam persediaan pantas, langkau langkah ini.
b. Pelancaran a web pelayar dan masukkan https://omada.tplinkcloud.com dalam bar alamat. Masukkan ID TP-Link dan kata laluan anda untuk log masuk. Senarai pengawal yang telah diikat dengan ID TP-Link anda akan muncul. Kemudian anda boleh mengklik Lancar untuk mengkonfigurasi pengawal selanjutnya.

Note: To manage your devices, Omada Pro Software Controller needs to keep running on your computer.

Melalui Pengawal Berasaskan Awan Omada Pro

Pengawal Berasaskan Awan Omada Pro ialah alternatif yang baik tanpa perlu memasang pengawal perisian pada PC.

Lesen perlu dibeli tambahan.

Rajah 4-4

Urus rangkaian melalui Pengawal Berasaskan Awan Omada Pro

Awan Omada

Gerbang

Tukar

AP

AP

AP

AP

Pelanggan
1. Contact the sales staff to grant the Omada Pro Cloud-Based Controller permission. 2. Launch a web pelayar dan masukkan https://omada.tplinkcloud.com dalam bar alamat. Log masuk dengan
your TP-Link ID.
30 Konfigurasi

Omada Campus Stackable L3 Managed Switch 3. Click + Add Controller and choose Cloud-Based Controller to add an Omada Pro Controller. Then
anda boleh melancarkan pengawal untuk menerima pakai dan mengurus peranti. * Apl Omada Dengan apl Omada, anda juga boleh mengurus pengawal anda di tapak setempat atau tapak jauh melalui peranti mudah alih anda. Untuk konfigurasi terperinci, rujuk kepada Panduan Pengguna pengawal. Panduan boleh didapati di pusat muat turun rasmi kami webtapak: https://support.omadanetworks.com/product/.
Konfigurasi 31

Omada Campus Stackable L3 Managed Switch
Lampiran A Penyelesaian Masalah
S1. Apa yang boleh saya lakukan sekiranya saya lupa nama pengguna dan kata laluan suis?
1. Sambungkan port konsol PC ke port konsol suis dan buka program emulasi terminal.
2. Matikan dan mulakan semula suis. Lakukan tindakan yang ditunjukkan oleh program emulasi terminal untuk mencapai menu bootUtil. Tindakan berbeza dari produk ke produk. Tindakan yang mungkin disenaraikan di bawah: · Tekan sebarang kekunci untuk menghentikan autoboot. · Tekan CTRL-B untuk mencapai menu bootUtil.
3. Menu bootUtil akan ditunjukkan. Masukkan nombor 6 untuk memilih pilihan "Pemulihan kata laluan" dan masukkan Y untuk memadam semua pengguna dan kata laluan. Kemudian anda boleh menetapkan semula nama pengguna dan kata laluan.
S2. Mengapa LED PWR berfungsi secara tidak normal? LED PWR/Kuasa hendaklah menyala apabila sistem kuasa berfungsi seperti biasa. Jika LED PWR/Kuasa berfungsi secara tidak normal, lakukan langkah berikut:
1. Pastikan bahawa kabel kuasa disambungkan dengan betul, dan sesentuh kuasa adalah normal. 2. Pastikan voltage bekalan kuasa memenuhi keperluan vol inputtage daripada
suis.
S3. Apakah yang perlu saya lakukan jika saya tidak dapat mengakses web halaman pengurusan? Cuba yang berikut:
1. Periksa setiap port LED pada suis dan pastikan kabel Ethernet disambungkan dengan betul. 2. Cuba port lain pada suis dan pastikan kabel Ethernet sesuai dan berfungsi seperti biasa. 3. Matikan suis dan, selepas beberapa ketika, hidupkan semula. 4. Pastikan alamat IP PC anda ditetapkan dalam subnet suis. 5. Jika anda masih tidak boleh mengakses halaman konfigurasi, tetapkan semula suis kepada lalai kilangnya. Kemudian
alamat IP PC anda hendaklah ditetapkan sebagai 192.168.0.x (“x” ialah sebarang nombor dari 2 hingga 254) dan subnet mask sebagai 255.255.255.0.
S4. Mengapakah program emulasi terminal tidak dipaparkan dengan betul? Cuba yang berikut:
1. Pastikan bekalan kuasa adalah normal dan kabel konsol disambungkan dengan betul. 2. Periksa sama ada kabel konsol adalah jenis yang betul. 3. Pastikan parameter program emulasi terminal adalah betul: konfigurasikan Bit sesaat
sebagai 38400, Bit data sebagai 8, Pariti sebagai Tiada, Bit Hentikan sebagai 1, dan Kawalan aliran sebagai Tiada.
32 Lampiran A Penyelesaian Masalah

Omada Campus Stackable L3 Managed Switch

Lampiran B Spesifikasi

Specifications for S6500 Series Switches

item

kandungan

IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ae, IEEE 802.3x

Piawaian

IEEE 802.3af/at (For S6500-24GP4XF, S6500-48GP6XF) IEEE 802.3af/at/bt (For S6500-24MPP4Y, S6500-48MPP6Y)

IEEE 802.3bz, IEEE 802.3by, IEEE 802.3cc (For S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y)

10BASE-T: 2-pair UTP/STP of Cat. 3,4,5 (maximum 100 m) 100BASE-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100 m) 1000BASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) 2.5GBASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) Transmission Medium 1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M)

S6500-24G4XF/S6500-24M4Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-24, Port 25-28 S6500-24GP4XF/S6500-24MPP4Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-24, Port 25-28 LED S6500-48G6XF/S6500-48M6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-48, Port 49-54 S6500-48GP6XF/S6500-48MPP6Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-48, Port 49-54

Lampiran B Spesifikasi 33

Omada Campus Stackable L3 Managed Switch

Bajet PoE

For S6500-24GP4XF: 402W (with 1*PSM500-AC, by default) 720W (with 1*PSM900-AC) 720W (with 2*PSM500-AC) 720W (with 1*PSM500-AC and 1*PSM900-AC) 720W (with 2*PSM900-AC) For S6500-48GP6XF: 764W (with 1*PSM900-AC, by default) 384W (with 1*PSM500-AC) 812W (with 2*PSM500-AC) 1176W (with 1*PSM500-AC and 1*PSM900-AC) 1440W (with 2*PSM900-AC) For S6500-24MPP4Y: 751W (with 1*PSM900-AC, by default) 378W (with 1*PSM500-AC) 802W (with 2*PSM500-AC) 1168W (with 1*PSM500-AC and 1*PSM900-AC) 1534W (with 2*PSM900-AC) For S6500-48MPP6Y: 701W (with 1*PSM900-AC, by default) 328W (with 1*PSM500-AC) 752W (with 2*PSM500-AC) 1118W (with 1*PSM500-AC and 1*PSM900-AC) 1484W (with 2*PSM900-AC)

Suhu Operasi & Ketinggian

For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters

Suhu Penyimpanan -40 °C hingga 70 °C (-40 °F hingga 158 °F)

Kelembapan Operasi 10% hingga 90% RH Tidak pemeluwapan

Kelembapan Penyimpanan

5% hingga 90% RH Tidak pemeluwapan

34 Lampiran B Spesifikasi

Omada Campus Stackable L3 Managed Switch

Specifications for S7500 Series Switches

item

kandungan

Piawaian

IEEE 802.3, IEEE 802.3x IEEE 802.3z, IEEE 802.3ae (For S7500-26XF6Y, S7500-48XF4C, S7500-24Y4C, S7500-48Y8C IEEE 802.3by, IEEE 802.3cc (For S7500-26XF6Y, S7500-24Y4C, S7500-48Y8C) IEEE 802.3 ba, IEEE 802.3bm (For S7500-48XF4C , S7500-24Y4C, S7500-48Y8C, S7500-32C)

1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M) 40GBASE-SR4/LR4: MMF, SMF (For S7500-48XF4C, S7500-24Y4C, Transmission Medium S7500-48Y8C, S7500-32C) 40G QSFP+ Direct Attach Cable (For S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100GBASE-SR4/LR4: MMF, SMF (SM9110-SR4 for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100G QSFP28 Direct Attach Cable (SM9220-1M for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C)

LED
Suhu Operasi & Ketinggian

S7500-26XF6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP+, SFP28 S7500-48XF4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP+, QSFP28 S7500-24Y4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP28, QSFP28 S7500-48Y8C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP28, QSFP28 S7500-32C: PWR1, PWR2, SYS, MGMT, FAN, MST, SPEED, STK, QSFP28 -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters

Suhu Penyimpanan -40 °C hingga 70 °C (-40 °F hingga 158 °F)

Kelembapan Operasi 10% hingga 90% RH Tidak pemeluwapan

Kelembapan Penyimpanan

5% hingga 90% RH Tidak pemeluwapan

For S7500-26XF6Y, S7500-48XF4C, and S7500-24Y4C, the maximum operating temperature supported can reach 50 °C (122 °F) @ 300 meters, 45 °C (113 °F) @ 2,000 meters, and 40 °C (104 °F) @ 3,000 meters.
Ketinggian yang disokong ialah paras laut hingga 5000 m. Perlu diingat bahawa apabila ketinggian melebihi 2000 m, untuk setiap peningkatan ketinggian 220 meter, suhu operasi maksimum akan turun sebanyak 1°C (1.8°F).

Lampiran B Spesifikasi 35

Omada Campus Stackable L3 Managed Switch

Spesifikasi untuk Modul Bekalan Kuasa

PSM500-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)

PSM900-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)

PSM550-AC
(For S6500-24M4Y/ S6500-48M6Y/ S7500-26XF6Y/ S7500-48XF4C/ S7500-24Y4C/ S7500-48Y8C/ S7500-32C)

Input Kuasa

100 V240 V~ 50/60 Hz 8A

100-120V (termasuk)~ 50/60Hz 12A (untuk lokasi yang menggunakan vol rendahtage, lihat spesifikasi untuk negara/rantau tertentu)
120 (tidak termasuk)240V~ 50/60Hz 10A (untuk lokasi lain)

100 V240 V~ 50/60 Hz 7A

Keluaran Voltage

Utama: 53.5 VDC Siap sedia: 12 VDC

Utama: 53.5 VDC Siap sedia: 12 VDC

Utama: 12 VDC Siap sedia: 12 VDC

Arus Keluaran

9.35 A (Maksimum)

16.5 A (Maksimum)

45 A (Maksimum)

Kuasa Keluaran

500 W (Maksimum)

900 W (Maksimum)

550 W (Maksimum)

Ketinggian Operasi

Untuk PSM500-AC/PSM900-AC: Paras laut hingga 3000 m Untuk PSM550-AC: Paras laut hingga 5000 m

36 Lampiran B Spesifikasi

Amaran Tanda CE
Ini adalah produk kelas A. Dalam persekitaran domestik, produk ini boleh menyebabkan gangguan radio, dalam hal ini pengguna mungkin dikehendaki mengambil langkah yang mencukupi.
Pengisytiharan Kepatuhan EU
TP-Link dengan ini mengisytiharkan bahawa suis itu mematuhi keperluan penting dan peruntukan lain yang berkaitan arahan 2014/30/EU, 2014/35/EU, 2011/65/EU dan (EU)2015/863. Deklarasi Pematuhan EU asal boleh didapati di https://www.tp-link.com/en/support/ce/
Pengisytiharan Pematuhan UK
TP-Link dengan ini mengisytiharkan bahawa suis itu mematuhi keperluan penting dan peruntukan lain yang berkaitan dalam Peraturan-Peraturan Keserasian Elektromagnet 2016 dan Peraturan-Peraturan Peralatan Elektrik (Keselamatan) 2016. Pengisytiharan Pematuhan UK asal boleh didapati di https://www.tp-link.com/support/ukca/
, .
PERHATIAN:
Tiang berganda, peleburan neutral. Putuskan sambungan utama sebelum diservis.
Maklumat Keselamatan
· Jauhkan peranti daripada air, api, kelembapan atau persekitaran yang panas. · Jangan cuba membuka, membaiki atau mengubah suai peranti. Jika anda memerlukan servis, sila hubungi kami. · Letakkan peranti dengan permukaan bawahnya ke bawah. · Palam pada kord bekalan kuasa digunakan sebagai peranti putus sambungan, soket-salur keluar hendaklah
Mudah diakses. · Palamkan produk ke dalam alur keluar dinding dengan sambungan pembumian melalui kord bekalan kuasa
or plug. · The socket-outlet shall be installed near the equipment and shall be easily accessible. · The PoE ports shall not be used to charge lithium batteries or devices supplied by lithium
bateri.

· Operating temperature: For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/ S7500-48XF4C/S7500-24Y4C: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters S7500-48Y8C/S7500-32C: -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
· : S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/ S7500-24Y4C -5°C 50°C23°F 122°F@ 300 -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S7500-48Y8C/S7500-32C -5°C 45°C23°F 113°F@ 300 -5°C 40°C23°F 104°F@ 2,000 -5°C 35°C23°F 95°F@ 3,000
This equipment is not suitable for use in locations
where children are likely to be present.

Sila baca dan ikuti maklumat keselamatan di atas semasa mengendalikan peranti. Kami tidak dapat menjamin bahawa tiada kemalangan atau kerosakan akan berlaku akibat penggunaan peranti yang tidak betul. Sila gunakan produk ini dengan berhati-hati dan beroperasi atas risiko anda sendiri.

Untuk sokongan teknikal, panduan pengguna dan maklumat lain, sila lawati https://support.omadanetworks.com/, atau hanya imbas kod QR.
© 2026 TP-Link 7100002759 REV2.0.1