KETOTEK KT2000

KETOTEK KT2000 Digital Thermostat Plug Instruction Manual

Model: KT2000

1. Pengenalan

Thank you for choosing the KETOTEK KT2000 Digital Thermostat Plug. This device is designed to provide precise temperature control for a wide range of applications, including home brewing, aquariums, terrariums, incubators, and seedling heat mats. Its user-friendly interface and robust features ensure stable and reliable temperature management.

KETOTEK KT2000 Digital Thermostat Plug with sensor

Image 1.1: The KETOTEK KT2000 Digital Thermostat Plug, showing the main unit with its display, control buttons, power socket, and the attached waterproof temperature sensor.

Apa yang ada di dalam Kotak:

  • 1 x KETOTEK KT2000 Digital Thermostat Plug
  • 1 x NTC Temperature Sensor (waterproof)

2. Maklumat Keselamatan

  • Ensure the device is connected to a power outlet with the correct voltage (230V AC).
  • Do not exceed the maximum resistive load of 2300W (16A).
  • Do not immerse the main unit in water. The temperature sensor is waterproof, but the main plug unit is not.
  • Jauhkan peranti daripada kanak-kanak.
  • Jangan buka atau cuba membaiki peranti itu sendiri. Hubungi kakitangan yang berkelayakan untuk perkhidmatan.
  • Sentiasa cabut plag peranti daripada salur keluar kuasa sebelum membersihkan atau melakukan sebarang penyelenggaraan.

3. Persediaan

  1. Pasangkan Termostat: Insert the KETOTEK KT2000 Digital Thermostat Plug into a standard 230V AC wall outlet.
  2. Sambungkan Sensor: Plug the NTC temperature sensor into the designated port on the bottom of the thermostat plug.
  3. Letakkan Penderia: Place the waterproof temperature sensor in the environment where you wish to monitor and control the temperature. Ensure it is securely positioned and will not be dislodged.
  4. Sambungkan Perkakas Anda: Plug your heating or cooling appliance (e.g., heater, fan, heat mat) into the power socket on the front of the KETOTEK KT2000.

4. Arahan Operasi

4.1. Memahami Paparan dan Butang

KETOTEK KT2000 LCD display and button functions

Imej 4.1: Terperinci view of the LCD display and control buttons. The display shows real-time temperature, set temperature, and indicators for heating/cooling mode and alarms. Buttons include Up, Down, and Mode (M).

  • Suhu masa nyata: The larger number on the display shows the current temperature measured by the sensor.
  • Tetapkan Suhu: The smaller number labeled "SET" indicates your desired target temperature.
  • Penunjuk Mod: Icons at the top left indicate heating (wavy lines) or cooling (snowflake) mode.
  • Petunjuk Penggera: A bell icon will appear if a temperature alarm is triggered.
  • Butang Atas (▲): Digunakan untuk meningkatkan nilai atau menavigasi menu.
  • Butang Bawah (▼): Used to decrease values or navigate menus.
  • Butang Mod (M): Used to enter settings, confirm selections, or switch between modes.

4.2. Setting the Temperature and Mode

  1. Masukkan Mod Tetapan: Tekan dan tahan butang M button for 3 seconds to enter the setting menu.
  2. Laraskan Suhu Tetapan: The set temperature value will flash. Use the dan buttons to adjust it to your desired temperature.
  3. Select Mode (Heating/Cooling): Tekan ke M button again to move to the mode selection. Use dan to choose between heating (indicated by wavy lines) or cooling (indicated by a snowflake).
  4. Set Hysteresis (Differential Value): Tekan M again. The hysteresis value (d) will flash. This is the temperature difference between the set point and when the device turns on/off. Adjust using dan . A range of 0.1°C to 30°C (0.5°F to 60°F) is available.
  5. Keluar dari Mod Tetapan: Tekan dan tahan butang M button for 3 seconds, or wait for 10 seconds for the device to automatically exit the setting mode.

4.3. Heating Mode Operation

KETOTEK KT2000 in heating mode with a radiator

Image 4.2: The thermostat plug operating in heating mode, connected to a radiator. The display shows the current temperature and the set temperature.

In heating mode, the connected appliance will turn on when the measured temperature falls below the set temperature minus the hysteresis value. It will turn off when the measured temperature exceeds the set temperature.

  • Load ON: Measured Temperature < Set Temperature - Hysteresis
  • Load OFF: Measured Temperature > Set Temperature

4.4. Operasi Mod Penyejukan

KETOTEK KT2000 in cooling mode with a fan

Image 4.3: The thermostat plug operating in cooling mode, connected to a fan. The display shows the current temperature and the set temperature.

In cooling mode, the connected appliance will turn on when the measured temperature rises above the set temperature plus the hysteresis value. It will turn off when the measured temperature falls below the set temperature.

  • Load ON: Measured Temperature > Set Temperature + Hysteresis
  • Load OFF: Measured Temperature < Set Temperature

4.5. Tetapan Lampu Latar

KETOTEK KT2000 HD LCD with backlight options

Image 4.4: The HD LCD screen of the KT2000, illustrating the adjustable backlight feature for clear visibility in various lighting conditions.

The backlight of the HD LCD screen can be adjusted for optimal visibility. You can set it to:

  • Sentiasa Hidup: The backlight remains continuously lit.
  • Sentiasa Mati: The backlight remains off.
  • Auto-Off (10 minutes): The backlight will automatically turn off after 10 minutes of inactivity to save power.

To adjust the backlight setting, refer to the advanced settings menu (usually accessed by a longer press of the M button or a specific button combination, consult the full manual for exact steps if not covered here).

4.6. Fungsi Penentukuran

The device includes a temperature calibration function to ensure accuracy. If you notice a discrepancy between the displayed temperature and a known accurate thermometer, you can adjust the calibration value. The calibration range is -10.0°C to 10.0°C (-20.0°F to 20.0°F).

To access calibration settings, refer to the advanced settings menu (usually accessed by a longer press of the M button or a specific button combination, consult the full manual for exact steps if not covered here).

4.7. High/Low Temperature Alarms

The KETOTEK KT2000 features high and low temperature alarms to prevent overheating or freezing. You can set specific temperature thresholds, and if the measured temperature goes above the high limit or below the low limit, an alarm will sound, and an indicator will appear on the display.

To set alarm thresholds, refer to the advanced settings menu (usually accessed by a longer press of the M button or a specific button combination, consult the full manual for exact steps if not covered here).

5. Ciri Berakhirview

  • Reka Bentuk Palam & Main: Easy to set up and use, no complex wiring required.
  • Kawalan Suhu Tepat: Offers a hysteresis range of 0.1°C to 30°C (0.5°F to 60°F) for stable and accurate temperature management with ±1°C (±2°F) precision.
  • HD LCD Screen with Adjustable Backlight: Clear display of real-time and set temperatures, visible in various lighting conditions with options for always on, always off, or 10-minute auto-off.
  • Fungsi Keselamatan: Includes high/low temperature alarms to prevent extreme temperature conditions and a calibration function for enhanced accuracy.
  • Aplikasi Serbaguna: Suitable for a wide range of uses including home brewing systems, plant growth environments (greenhouses, seedling heat mats), aquariums, animal care (reptile terrariums, incubation), and electric radiator temperature control.
KETOTEK KT2000 versatile applications collage

Image 5.1: A collage demonstrating various applications of the KETOTEK KT2000, including home brewing, plant cultivation, aquariums, pet breeding, greenhouses, incubation, reptile care, and seedling heat mats.

6. Penyelenggaraan

  • Pembersihan: Lap unit utama dengan kain lembut dan kering. Jangan gunakan pembersih atau pelarut yang kasar.
  • Penjagaan Sensor: Ensure the temperature sensor is clean and free from debris for accurate readings. The waterproof sensor can be gently cleaned with water.
  • Storan: Apabila tidak digunakan, simpan peranti di tempat yang sejuk dan kering jauh dari cahaya matahari langsung dan suhu yang melampau.

7. Penyelesaian masalah

If you encounter issues with your KETOTEK KT2000, please refer to the following common problems and solutions:

  • Peranti tidak dihidupkan:
    • Ensure the thermostat plug is securely inserted into a working 230V AC outlet.
    • Check if the power outlet itself is functional by plugging in another device.
  • Bacaan suhu tidak tepat:
    • Verify that the temperature sensor is correctly connected to the main unit.
    • Ensure the sensor is properly positioned in the environment you wish to measure.
    • Consider using the calibration function (Section 4.6) if you suspect a consistent offset.
  • Appliance not turning on/off as expected:
    • Check if the thermostat is set to the correct mode (heating or cooling) for your application.
    • Verify the set temperature and hysteresis values are configured correctly (Section 4.2).
    • Ensure your appliance is properly plugged into the thermostat's socket and is functional.
  • Paparan malap atau dimatikan:
    • Check the backlight settings (Section 4.5) to ensure it's not set to 'Always Off' or in auto-off mode.

If the problem persists, please contact KETOTEK customer support for further assistance.

8. Spesifikasi

KETOTEK KT2000 temperature control range and load capacity

Image 8.1: Visual representation of the KETOTEK KT2000's temperature control range (-50°C to 110°C / -58°F to 230°F) and maximum resistive load (16A / 2300W).

KETOTEK KT2000 dimensions

Image 8.2: Dimensions of the KETOTEK KT2000 Digital Thermostat Plug and its sensor cable length.

SpesifikasiNilai
JenamaKETOTEK
Nombor ModelKT2000
warnaHitam
Dimensi Produk (L x W x H)8.5 x 6 x 11.5 cm
Berat Barang240 gram
Voltage250 Volt (AC)
bahanplastik
Ciri-ciriTemperature Display, High/Low Alarms, Calibration
Jenis PengawalButang Tekan
Kegunaan Khusus untuk ProdukGeneral temperature control for various applications
Jenis Kawalan SuhuAutomatik
Komponen yang DisertakanThermostatic plug with NTC temperature sensor
Sumber KuasaKabel Elektrik
Julat Suhu-50°C hingga 110°C (-58°F hingga 230°F)
Hysteresis Range0.1°C hingga 30°C (0.5°F hingga 60°F)
KeluaranRelay 16A Max.
Beban Rintangan≤ 2300 W
Beban Induktif≤ 460 W
Ketersediaan Alat GantiMaklumat tidak tersedia pada alat ganti

9. Waranti dan Sokongan

KETOTEK products are designed for reliability and performance. For warranty information or technical support, please refer to the product packaging or contact KETOTEK customer service through their official webtapak atau peruncit tempat produk itu dibeli.

Dokumen Berkaitan - KT2000

Praview Manual Pengguna Termostat Pemalam Ketotek KT3200
Manual arahan untuk Termostat Pemalam Ketotek KT3200, Pengawal Suhu Siang/Malam. Butiran mod operasi (M1 TC, M2 TC+Pemasa, M3 Pemasa), penentukuran suhu, fungsi set semula dan ciri memori.
Praview Manual Arahan Termostat Pemalam KETOTEK KT3100 AS
Ketahui cara mengendalikan KETOTEK KT3100 US Plug-in Thermostat. Manual ini merangkumi kawalan suhu (pemanasan/penyejukan), mod pemasaan (berbasikal, kira detik), penentukuran dan spesifikasi untuk pengurusan suhu pintar.
Praview Manual Arahan Termostat Pemalam KETOTEK KT3100 AS
Ketahui cara mengendalikan KETOTEK KT3100 US Plug-in Thermostat, pengawal suhu serba boleh untuk aplikasi pemanasan, penyejukan dan pemasaan di rumah, rumah hijau dan akuakultur. Manual ini merangkumi persediaan, kawalan suhu, mod pemasaan dan spesifikasi.
Praview Panduan Penyelesaian Masalah Termostat KETOTEK | Selesaikan Isu Biasa
Cari penyelesaian untuk masalah termostat KETOTEK yang biasa termasuk suhu yang tidak tepat, isu kuasa, kod ralat dan persediaan masa. Ketahui tentang penentukuran dan sokongan jaminan.
Praview Manual Pengendalian Pengawal Kelembapan Suhu KETOTEK KT100 Fahrenheit
Manual pengendalian yang komprehensif untuk Pengawal Kelembapan Suhu KETOTEK KT100 Fahrenheit, butiran spesifikasi, pendawaian, arahan operasi dan prosedur penentukuran untuk kawalan suhu dan kelembapan.
Praview Manual Pengendalian Pengawal Suhu KT1000 - Ketotek
Manual operasi terperinci untuk Pengawal Suhu Ketotek KT1000. Meliputi spesifikasi, gambar rajah pendawaian, operasi utama, tetapan parameter, dan arahan operasi untuk aplikasi penyejukan dan pemanasan dalam persekitaran industri dan domestik.