Minuteman EN450G

Minuteman EN450G 450VA Standby UPS User Manual

Model: EN450G

1. Pengenalan

This manual provides essential instructions for the safe and efficient operation of your Minuteman EN450G 450VA Standby Uninterruptible Power Supply (UPS). The EN450G is designed to provide reliable backup power and surge protection for various electronic devices, including gaming consoles, desktop PCs, home office equipment, and network devices. Please read this manual thoroughly before installation and use, and retain it for future reference.

2. Arahan Keselamatan Penting

WARNING: To reduce the risk of electric shock, fire, or injury to persons, read all instructions before using this product.

3. Produk Lebihview

The Minuteman EN450G UPS provides comprehensive power protection. Familiarize yourself with its components:

Minuteman EN450G 450VA Standby UPS showing front and top view with outlets and controls.

Rajah 1: Minuteman EN450G UPS Unit. This image displays the Minuteman EN450G UPS unit. The front panel features the 'Minuteman Power Technologies' logo, two USB charging ports, and control buttons. The top surface shows four 'Battery & Surge' protected outlets and four 'Surge Only' outlets, clearly labeled. The unit is black and designed for compact placement.

3.1 Ciri Panel Depan

3.2 Ciri Panel Belakang

4. Persediaan dan Pemasangan

4.1 Membongkar

Buka bungkusan UPS dengan berhati-hati dan periksa untuk sebarang kerosakan penghantaran. Jika kerosakan ditemui, jangan kendalikan unit ini dan hubungi pengedar anda.

4.2 Penempatan

The EN450G is designed for versatile placement:

Ensure the installation area is clean, dry, and has adequate ventilation. Avoid placing the UPS near heat-emitting appliances or in direct sunlight.

4.3 Menyambung ke Kuasa

  1. Pastikan UPS dimatikan.
  2. Plug the UPS power cord into a grounded 120V AC wall outlet.
  3. Allow the UPS to charge for at least 8 hours before initial use to ensure optimal battery runtime.

4.4 Menyambung Peranti

CAUTION: Do not connect laser printers or shredders to the battery backup outlets, as their high power draw can overload the UPS.

5. Operasi

5.1 Menghidupkan/Mematikan UPS

5.2 Petunjuk Status

The front panel LEDs provide information about the UPS status:

5.3 Battery Runtime

The EN450G provides approximately 3 minutes of runtime at full load (450VA/255W) and 11 minutes at half load. Actual runtime may vary based on connected equipment and battery age.

6. Penyelenggaraan

6.1 Penggantian Bateri

The EN450G features a hot-swappable Sealed Lead Acid (SLA) battery, allowing replacement without interrupting power to connected devices. Batteries typically last 3-5 years depending on usage and environmental conditions. A flashing red LED or continuous alarm may indicate a need for battery replacement.

  1. Ensure the UPS is connected to AC power and operating normally.
  2. Locate the battery access panel (refer to product diagram if available).
  3. Carefully slide out the old battery pack.
  4. Insert the new, fully charged replacement battery pack, ensuring correct orientation.
  5. Secure the battery access panel.
  6. Allow the new battery to charge for 8-12 hours to reach full capacity.

WARNING: Use only approved replacement batteries. Improper battery replacement can result in fire or explosion. Dispose of old batteries properly at a recycling facility.

6.2 Pembersihan

Periodically clean the exterior of the UPS with a soft, dry cloth. Do not use liquid or aerosol cleaners. Ensure ventilation openings remain clear of dust and debris.

7. Penyelesaian masalah

This section addresses common issues you may encounter with the EN450G UPS. If a problem persists after attempting the solutions below, contact technical support.

MasalahKemungkinan PuncaPenyelesaian
UPS tidak dihidupkan.Bateri tidak disambungkan atau dinyahcas.
Kord kuasa tidak disambungkan.
Ensure battery is properly connected and charged.
Verify power cord is securely plugged into wall outlet and UPS.
UPS beeps continuously or red LED is solid.Battery low or fault condition.
Overload on battery outlets.
Allow battery to charge. If problem persists, battery may need replacement.
Disconnect non-essential devices from battery outlets. Check circuit breaker.
UPS operates on battery frequently.Unstable incoming AC power.
UPS sensitivity setting (if applicable, though not specified for this model).
Check the quality of your incoming AC power. Consider connecting to a different outlet.
No power from surge-only outlets.Pemutus litar tersekat.Press the circuit breaker reset button on the rear panel. Reduce load if necessary.

8. Spesifikasi

CiriPerincian
ModelEN450G
Kapasiti450VA / 255W
Input/Output Voltage120V AC
Bentuk Gelombang OutputGelombang Sinus Simulasi
Outlet4 x Battery & Surge Protected, 4 x Surge Only
Jenis BateriSealed Lead Acid (SLA), Hot-Swappable
Typical Runtime (Full Load)Sehingga 3 minit
Typical Runtime (Half Load)Sehingga 11 minit
Dimensi (D x W x H)12.8 x 5.7 x 4.1 inci (32.5 x 14.5 x 10.4 cm)
Berat badan4.4 paun (2 kg)
Pilihan PemasanganDesktop, Floor, Wall Mount

9. Maklumat Waranti

Please refer to the warranty card included with your product or visit the manufacturer's webtapak untuk terma dan syarat jaminan terperinci. Simpan bukti pembelian anda untuk tuntutan waranti.

10. Sokongan Teknikal

If you require technical assistance or have questions regarding your Minuteman EN450G UPS, please contact your dealer or the manufacturer's customer support. Have your model number (EN450G) and serial number ready when contacting support.

For more information, you may visit the official Minuteman webtapak.

Dokumen Berkaitan - EN450G

Praview Minuteman Enspire Series UPS User Manual (EN450G, EN600GU, EN750G)
This comprehensive user manual for the Minuteman Enspire Series UPS (models EN450G, EN600GU, EN750G) provides essential guidance on installation, operation, safety, troubleshooting, and specifications for reliable power protection.
Praview MINUTEMAN Enspire Series Manual Pengguna UPS EN350 / EN550
Manual pengguna yang komprehensif untuk model UPS MINUTEMAN Enspire Series EN350 dan EN550. Menyediakan maklumat terperinci tentang pemasangan, operasi, kawalan, penunjuk, penyelesaian masalah, penggantian bateri, spesifikasi, waranti dan pengisytiharan pematuhan.
Praview Minuteman RPM-LCD UPS Series Quick Install Guide and Specifications
Quick installation guide, features, and warranty information for the Minuteman RPM-LCD UPS Series. Learn how to install and configure your network UPS.
Praview Minuteman Endeavor UPS Series User's Manual 5-10kVA Rack/Tower
User's manual for the Minuteman Endeavor UPS Series, covering 5-10kVA Rack/Tower models. Provides installation, configuration, operation, and troubleshooting instructions for power protection.
Praview Minuteman UPS Quick Reference Guide
Quick reference guide detailing features and specifications for Minuteman Power Technologies' range of UPS systems, including Entry Level, Rackmount (EXR Series), and Online (Encompass, Endeavor, ED6/10KTF Series) UPS units. Compares models, UPS topology, load capacity, output signals, receptacles, and other key features.
Praview Minuteman SV Online Series UPS User's Manual
Comprehensive user manual for the Minuteman SV Online Series UPS, detailing installation, operation, safety, maintenance, and specifications. Covers models from 1kVA to 3kVA.