The Corning CCH Pigtailed Splice Cassette, model CCH-CS12-AE-P00RE, is designed to facilitate faster field splicing and provide modular management of connectorization within fiber optic housings. This cassette is preloaded and pre-routed for efficient fusion splicing of individual or ribbon fiber pigtails, utilizing the same space-saving platform as standard CCH splice cassettes. It aims to reduce field labor by streamlining components and features, allowing for greater efficiency in fiber optic installations.
The cassette is prepped with a 3-meter pigtail assembly, compatible with all pre-existing CCH panel connector options. It features 900 µm cabling at the connector panel for enhanced durability and colored 250 µm fibers for ease of splicing. Strain relief is pre-applied from the manufacturing facility. This modular design allows for easy access to fibers within an individual cassette without disturbing other fibers in the housing.
2. Ciri-ciri Utama
- Nombor Bahagian: CCH-CS12-AE-P00RE
- Jenis gentian: Mod tunggal (OS2)
- Jenis Penyambung: LC Duplex Shuttered
- Kiraan Gentian: 12 Serat
- Jenis Poland: UPC Poland
- Jenis Kabel: 250 µm (colored for ease of splicing)
- Ketahanan: 900 µm at the connector panel
- Termasuk: 12 Splice Protectors
- Modulariti: Allows splicing away from the rack housing
- Keserasian: Designed for use with CCH-01U/2U/3U/4U housings
3. Apa yang ada di dalam Kotak
The package for the Corning CCH-CS12-AE-P00RE Pigtailed Splice Cassette typically includes the following components:
- One (1) Pigtailed CCH Adapter Panel (pre-routed with 3m pigtail assembly)
- One (1) Rail for use with CCH-01U/2U/3U housings
- Two (2) Rails for use with CCH-04U housings
- Grommets for additional strain relief
- Cable ties for additional strain relief
- Protective braided tubing for incoming cable
- Appropriate quantity and type of heat-shrink splice protectors (12 included)

Figure 1: The Corning CCH-CS12-AE-P00RE Pigtailed Splice Cassette as packaged, showing the front view with product labels and connectors.
4. Persediaan dan Pemasangan
The CCH pigtailed splice cassette is designed for straightforward installation within compatible Corning CCH housings. The pre-routed pigtails and included accessories simplify the splicing process.
4.1. Langkah Pemasangan Umum
- Housing Preparation: Ensure your CCH-01U, CCH-02U, CCH-03U, or CCH-04U housing is properly mounted and ready for cassette insertion.
- Cassette Insertion: Slide the pigtailed splice cassette into the designated slot within the CCH housing. Use the appropriate rails provided (one rail for 01U/02U/03U, two rails for 04U).
- Incoming Cable Routing: Route the incoming fiber optic cable into the housing and through the protective braided tubing provided. Secure the cable using the grommets and cable ties for strain relief.
- Pigtail Routing: The pigtails are pre-routed within the cassette. Ensure they are not kinked or excessively bent.
- Penyambungan: Perform fusion splicing of the incoming fibers to the 250 µm colored pigtail fibers. The modular design allows splicing to be done away from the rack housing in a suitable workspace, if preferred. Utilize the included heat-shrink splice protectors for each splice.
- Connectorization: Connect the LC UPC duplex shuttered connectors to the appropriate ports on your equipment or patch panel.
4.2. Routing Diagrams and Details

Figure 2: Detailed routing diagrams for the CCH-CS12-AE-P00RE cassette, showing fiber paths for 1U/2U/3U housings, pigtail management, splice tray layout, and incoming cable routing. For 4U routing, refer to Corning document SRP 003-895.
For detailed routing instructions specific to your CCH housing type, refer to the diagrams provided on the product packaging and the official Corning documentation. Specifically, for 4U routing, consult Corning document SRP 003-895.

Rajah 3: Sisi view of the CCH-CS12-AE-P00RE cassette, highlighting the LC UPC duplex shuttered connectors and the compact design.
4.3. Important Resources
- Corning LAN-1550-AEN.pdf: www.Corning.com/LAN-1550-AEN.pdf
- Corning 003-895.pdf (for 4U routing details): www.Corning.com/003-895.pdf
5. Operasi
The Corning CCH Pigtailed Splice Cassette is a passive component designed to organize and protect fiber optic splices and connections within a fiber optic housing. Its primary function is to provide a secure and accessible environment for fusion splicing and subsequent connection to active equipment or patch panels.
5.1. Fiber Management
Once installed and spliced, the cassette effectively manages the fiber slack and protects the delicate splice points. The modular design allows for individual cassette access, meaning you can work on or inspect fibers within one cassette without disturbing the connections or splices in adjacent cassettes within the same housing.
5.2. Ketersambungan
The LC UPC duplex shuttered connectors on the cassette provide a reliable interface for connecting to network devices, switches, or other fiber optic equipment. The shutters protect the ferrule ends from dust and debris when not in use, maintaining optimal signal integrity.
6. Penyelenggaraan
Proper maintenance of fiber optic components is crucial for ensuring long-term performance and reliability. While the CCH splice cassette itself requires minimal maintenance, the connected fibers and connectors do.
6.1. Pembersihan Penyambung
Regular cleaning of the LC UPC duplex connectors is highly recommended. Dust, dirt, and oils can significantly degrade optical performance. Use only approved fiber optic cleaning tools and methods, such as lint-free wipes with isopropyl alcohol or specialized one-click cleaners. Always inspect connectors with a fiber inspection microscope before and after cleaning.
6.2. Pengurusan Kabel
Ensure that all incoming and outgoing cables are properly routed and secured within the housing, avoiding sharp bends or excessive tension. Verify that strain relief mechanisms (grommets, cable ties) are functioning correctly.
6.3. Pertimbangan Alam Sekitar
Keep the housing and cassette free from dust and moisture. Operate within the specified environmental conditions to prevent damage to the fiber optic components.
7. Penyelesaian masalah
Most issues related to fiber optic connectivity stem from dirty connectors, damaged fibers, or improper splicing. The CCH splice cassette itself is a passive component and is unlikely to be the direct cause of signal issues unless physically damaged.
7.1. Isu dan Penyelesaian Biasa
- High Optical Loss / No Signal:
- Punca: Dirty connectors. Penyelesaian: Clean all LC UPC connectors thoroughly using appropriate fiber optic cleaning tools.
- Punca: Poor fusion splice. Penyelesaian: Re-inspect splices using an OTDR or visual fault locator (VFL). Re-splice if necessary.
- Punca: Kinked or damaged fiber within the cassette or housing. Penyelesaian: Carefully inspect fiber routing for any sharp bends or physical damage.
- Punca: Incorrect fiber type (e.g., multimode connected to single-mode equipment). Penyelesaian: Verify that OS2 single-mode fiber is used throughout the link.
- Sambungan Terputus-putus:
- Punca: Penyambung longgar. Penyelesaian: Ensure all LC connectors are fully seated and latched.
- Punca: Vibration or movement affecting connections. Penyelesaian: Ensure the cassette is securely installed in the housing and all cables are properly strain-relieved.
If issues persist after performing these checks, it is recommended to use specialized fiber optic testing equipment (e.g., Optical Power Meter, OTDR) to diagnose the exact location and nature of the fault.
8. Spesifikasi Teknikal
| Atribut | Perincian |
|---|---|
| Nombor Bahagian | CCH-CS12-AE-P00RE |
| Kiraan Serat | 12 Serat |
| Jenis Gentian | Mod tunggal (OS2) |
| Jenis Penyambung | LC Duplex Shuttered |
| Jenis Poland | UPC |
| Panjang Pigtail | 3 meter |
| Cable Type (Pigtail) | 250 µm colored fibers, 900 µm at connector panel |
| Splice Protectors Included | 12 heat-shrink splice protectors |
| Perumahan Serasi | Corning CCH-01U, CCH-02U, CCH-03U, CCH-04U |
| Dimensi Pakej | 14 x 8 x 3 inci |
| Berat Barang | 3 paun |
| Pengeluar | Corning |
| Tarikh Mula-mula Tersedia | 7 Ogos 2025 |
9. Maklumat Waranti
Specific warranty terms and conditions for the Corning CCH-CS12-AE-P00RE Pigtailed Splice Cassette are provided by the manufacturer, Corning. Please refer to the official documentation included with your product or visit the official Corning website for detailed warranty information, including coverage period, terms, and conditions.
Note: This manual does not constitute a warranty. All warranty claims must be made directly through Corning or an authorized reseller.
10. Sokongan dan Maklumat Hubungan
For technical support, product inquiries, or assistance with the Corning CCH-CS12-AE-P00RE Pigtailed Splice Cassette, please contact Corning directly.
10.1. Manufacturer Contact
Pengeluar: Corning
Please visit the official Corning website for the most up-to-date contact information, technical documentation, and support resources.
- Corning Official Webtapak: www.corning.com
When contacting support, please have your product model number (CCH-CS12-AE-P00RE) and any relevant purchase details ready.