FireAngel SW1-R

FireAngel SW1-R Mains Powered Optical Smoke Alarm User Manual

Model: SW1-R

1. Produk Lebihview

The FireAngel SW1-R is a mains-powered optical smoke alarm designed to provide early warning of fire. It features a 9V backup battery to ensure continuous protection during power outages. The alarm emits a loud 85dB sound at 3 meters and includes LED visual indicators for clear alerts.

This optical smoke alarm is particularly effective at detecting slow-burning fires that produce thick white smoke, making it suitable for general living areas.

Ciri-ciri Utama:

FireAngel SW1-R Smoke Alarm front view

Rajah 1: Depan view of the FireAngel SW1-R Mains Powered Optical Smoke Alarm.

FireAngel SW1-R Smoke Alarm with packaging and key features

Figure 2: FireAngel SW1-R Smoke Alarm highlighting its 9V backup battery, audible/visual alerts, and large test button.

2. Maklumat Keselamatan Penting

Sila baca semua arahan dengan teliti sebelum pemasangan dan operasi. Simpan manual ini untuk rujukan masa hadapan.

FireAngel SW1-R Smoke Alarm placement guidelines

Figure 3: Illustration of recommended placement guidelines for the smoke alarm, showing distance from walls and light fittings, and unsuitable locations.

3. Kandungan Pakej

Sahkan bahawa semua item ada dan tidak rosak semasa membuka bungkusan:

4. Panduan Pemasangan

Penting: Installation should only be performed by a competent person or qualified electrician. Ensure the mains power supply is switched off at the consumer unit before commencing installation.

4.1. Langkah Pra-Pemasangan:

  1. Pilih Lokasi: Choose a suitable location on the ceiling, adhering to the placement guidelines (refer to Section 2).
  2. Putuskan Kuasa: Turn off the mains electricity supply to the circuit where the alarm will be installed.
  3. Pasang Bateri Sandaran: Open the battery compartment on the alarm unit and insert the supplied 9V battery, observing polarity. Close the compartment securely.

4.2. Mounting the Alarm:

  1. Tandakan Titik Penggerudian: Hold the base plate against the ceiling at your chosen location and mark the two drilling points.
  2. Lubang gerudi: Drill holes at the marked points and insert the rawl plugs.
  3. Plat Asas Gunung: Secure the base plate to the ceiling using the provided screws.
  4. Sambungan Pendawaian: Connect the mains wiring (Live, Neutral, Earth, and Interlink if applicable) to the terminal block provided. Ensure connections are secure and correct. The alarm unit connects to this terminal block.
  5. Attach Alarm Unit: Align the smoke alarm unit with the base plate and twist clockwise until it clicks securely into place.
FireAngel SW1-R Smoke Alarm easy installation steps

Figure 4: Visual guide for easy installation, showing steps like installing the backup battery, mounting the bracket, attaching the alarm, and connecting to mains power.

4.3. Interlinking Multiple Alarms:

The SW1-R can be hardwired and interconnected with up to 12 compatible FireAngel mains-powered smoke (SW1), heat (HW1), or carbon monoxide (CW1) alarms. To interlink, connect the interlink wire between the designated terminals on each alarm's base plate. When one interlinked alarm detects a hazard, all connected alarms will sound simultaneously.

4.4. Semakan Selepas Pemasangan:

  1. Pulihkan Kuasa: Turn the mains electricity supply back on.
  2. Penggera Ujian: Press and hold the Test/Silence button for 5 seconds to confirm the alarm is functioning correctly. A loud, high-pitched sound indicates proper operation.

5. Arahan Operasi

5.1. Operasi Biasa:

Under normal conditions, the alarm will periodically flash its LED indicator to show it is powered and monitoring for smoke. If smoke is detected, the alarm will sound a loud siren and the LED will flash rapidly.

5.2. Test/Silence Button:

5.3. Sleep Easy Function:

If the 9V backup battery is low, the alarm will emit a regular "chirp" sound. To temporarily silence these low battery chirps for up to 8 hours, press the Test/Silence button. This allows for an uninterrupted night's sleep while still maintaining protection. Replace the battery as soon as possible after using this function.

6. Penyelenggaraan

Regular maintenance ensures the continued reliability and effectiveness of your smoke alarm.

FireAngel SW1-R Smoke Alarm maintenance tips

Figure 5: Visual summary of key maintenance recommendations for the smoke alarm, including monthly testing and quarterly vacuuming.

7. Penyelesaian masalah

If your smoke alarm is not operating as expected, refer to the following table for common issues and solutions:

MasalahKemungkinan PuncaPenyelesaian
Alarm chirps intermittentlyLow 9V backup battery.Replace the 9V battery immediately. Use the Sleep Easy function if needed for temporary silence.
Alarm sounds without visible smoke (false alarm)Dust or debris in the sensing chamber; high humidity; cooking fumes; steam.Press the Test/Silence button to temporarily silence. Vacuum the alarm thoroughly. Relocate the alarm if it's consistently affected by cooking fumes or steam.
Penggera tidak berbunyi semasa ujianNo mains power; flat 9V backup battery; faulty unit.Check mains power supply. Replace 9V battery. If problem persists, contact customer support.
Interlinked alarms do not all soundFaulty interlink wiring; incompatible alarms; too many alarms interlinked.Check interlink wiring connections. Ensure all interlinked alarms are compatible FireAngel models. Do not exceed 12 interlinked alarms.

8. Spesifikasi Teknikal

Nombor ModelSW1-R
Jenis SensorOptical (Photoelectric)
Sumber KuasaMains Powered (230V AC) with 9V DC Battery Backup
Kelantangan Penggera85dB pada 3 meter
Interlink CapabilityUp to 12 compatible FireAngel mains-powered alarms
Dimensi Produk (D x W x H)4.2D x 12.6W x 12.6H Sentimeter
Berat Barang220 Gram
Suhu OperasiRefer to product packaging for specific range
Julat KelembapanRefer to product packaging for specific range
PiawaianBS EN 14604: 2005
UPC816317004422
FireAngel SW1-R Smoke Alarm with UKCA and CE marks

Figure 6: The FireAngel SW1-R Smoke Alarm displaying its UKCA and CE certifications, indicating compliance with safety standards.

9. Waranti dan Sokongan Pelanggan

9.1. Maklumat Waranti:

The FireAngel SW1-R Mains Smoke Alarm comes with a Waranti 5 tahun dari tarikh pembelian. Waranti ini melindungi kecacatan pada bahan dan mutu kerja di bawah penggunaan biasa. Sila simpan bukti pembelian anda untuk tuntutan waranti.

The warranty does not cover damage caused by misuse, accidental damage, unauthorized modifications, or failure to follow the instructions in this manual.

9.2. Sokongan Pelanggan:

For technical assistance, warranty claims, or further information regarding your FireAngel SW1-R smoke alarm, please contact FireAngel customer support. Refer to the FireAngel official website or product packaging for the most up-to-date contact details.

Webtapak: www.fireangel.co.uk (Cthamppautan, pautan sebenar mungkin berbeza mengikut wilayah)

Dokumen Berkaitan - SW1-R

Praview FireAngel HW1 Mains Powered Heat Alarm User Manual
Comprehensive user manual for the FireAngel HW1 Mains Powered Heat Alarm with 9V battery backup. Includes installation, positioning, silencing features, interconnecting options, maintenance, troubleshooting, and warranty information.
Praview FireAngel Smoke & Heat Alarm User Manual: FA6611, FA6615, FA6620, FA6720
Comprehensive user manual for FireAngel FA6611, FA6615, FA6620 optical smoke alarms and FA6720 heat alarm. Covers installation, maintenance, troubleshooting, warranty, and disposal.
Praview FireAngel ST-625-INT Smoke Alarm User Manual
Comprehensive user manual for the FireAngel ST-625-INT smoke alarm, covering installation, features, maintenance, and warranty. This guide provides essential safety information and operational instructions.
Praview FireAngel FA6111, FA6115, FA6120 Smoke Alarms & FA6215 Heat Alarm User Manual
Comprehensive user manual for FireAngel FA6111, FA6115, FA6120 optical smoke alarms and FA6215 heat alarm, covering installation, maintenance, troubleshooting, features like Silence and Sleep Easy, warranty, and disposal.
Praview Manual Pengguna Gabungan Asap dan Karbon Monoksida FireAngel SCB10
User manual for the FireAngel SCB10, a combination smoke and carbon monoxide alarm, providing comprehensive instructions on installation, operation, maintenance, and safety for residential use.
Praview FireAngel FA6611, FA6615, FA6620 Smoke & FA6720 Heat Alarm User Manual
User manual for FireAngel FA6611, FA6615, FA6620 optical smoke alarms and FA6720 heat alarm. Includes installation, positioning, maintenance, troubleshooting, warranty, and disposal information.