Renogy RIV1230P2-126

Manual Arahan Inverter Gelombang Sinus Tulen Renogy 3000W 12V Pro

Model: RIV1230P2-126

1. Pengenalan

The Renogy 3000W 12V Pro Pure Sine Wave Inverter converts 12V DC battery power into stable 110V/120V AC household electricity. This inverter is designed for reliable performance in various applications, including RVs, trucks, and off-grid home energy systems. Key features include a 3000W continuous power output, 6000W peak power, built-in Bluetooth for monitoring, an EcoSleep mode for energy conservation, and a remote controller for convenient operation.

Renogy 3000W 12V Pro Pure Sine Wave Inverter with remote control and cable

Figure 1: Renogy 3000W 12V Pro Pure Sine Wave Inverter with included remote control and communication cable.

2. Maklumat Keselamatan

Please read and understand all safety instructions before installing or operating the inverter. Failure to follow these instructions may result in electrical shock, fire, or serious injury.

  • The inverter is UL 458 & CSA C22.2 No. 107.1 certified, ensuring compliance with safety and quality standards.
  • Ensure the inverter chassis is properly grounded to prevent electrical hazards.
  • The inverter features pre-charging functionality to ensure a smooth start, protecting both the battery and the inverter from high peak currents during connection.
  • Dual-polarity reverse connection protection is integrated to prevent internal damage in case of accidental misconnection of battery positive and negative terminals. However, always verify correct polarity before making connections.
  • Be aware that the surge capacity of inductive appliances can exceed their continuous rating by 5 to 7 times. Plan your loads accordingly to avoid unexpected shutdowns.
  • Do not expose the inverter to rain, moisture, or excessive dust.
  • Kendalikan inverter di kawasan yang mempunyai pengudaraan yang baik untuk mengelakkan terlalu panas.
Diagram illustrating pre-charging and dual-polarity reverse protection features of the inverter

Figure 2: Inverter security features including pre-charging and dual-polarity reverse protection.

Renogy inverter with GFCI, FCC, and ETL certifications shown, with a boat in the background

Figure 3: Essential safety protections including GFCI, FCC, and ETL certifications.

3. Persediaan

3.1 Pemasangan

Mount the inverter in a dry, well-ventilated area, away from direct sunlight, heat sources, and flammable materials. Ensure there is adequate space around the inverter for proper airflow and cooling.

3.2 Sambungan Input DC

Connect the inverter to your 12V battery bank. Use appropriate gauge cables for the power rating. The inverter is equipped with dual-polarity reverse connection protection, but it is crucial to always connect the positive (+) terminal of the inverter to the positive (+) terminal of the battery and the negative (-) terminal of the inverter to the negative (-) terminal of the battery. The pre-charging function will help protect the system during initial connection.

Person connecting battery cables to the inverter, highlighting reverse polarity protection

Figure 4: Connecting battery cables to the inverter, demonstrating reverse polarity protection.

3.3 Sambungan Output AC

The inverter provides two standard AC sockets and one AC terminal block for connecting your AC loads. Ensure that the total continuous power draw of your appliances does not exceed 3000W. For permanent installations, use the AC terminal block following local electrical codes.

3.4 Remote Controller Connection

Connect the included 16.4ft wired remote controller to the designated port on the inverter. This allows for convenient power control and monitoring from a distance.

Renogy remote controller for the inverter

Figure 5: The Renogy wired remote controller.

4. Arahan Operasi

4.1 Menghidupkan/Mematikan

To power on the inverter, press the power button on the unit or the remote controller. The indicator lights will confirm operation. To power off, press the button again.

4.2 EcoSleep Mode

The intelligent EcoSleep mode conserves energy by automatically switching the inverter to a low-power sleep state when no load is detected. In this mode, idle power consumption is less than 10W. The inverter will automatically wake up when an AC load is connected or detected.

Renogy inverter with a smartphone displaying EcoSleep mode settings

Figure 6: Inverter operating in EcoSleep mode, showing smartphone monitoring interface.

Renogy inverter installed in an RV with EcoSleep mode indicator

Figure 7: Inverter in an RV setup, demonstrating EcoSleep mode activation.

4.3 Bluetooth Monitoring

The inverter features built-in Bluetooth connectivity, allowing for real-time monitoring via a compatible smartphone application. It also supports RV-C connectivity for seamless integration with Renogy One Core/M1 systems, providing enhanced control and convenience.

Smartphone screens displaying the Renogy inverter monitoring application

Figure 8: Real-time monitoring of the inverter via a smartphone application.

Diagram showing the inverter powering various RV appliances like TV, coffee maker, air conditioner, microwave, and portable freezer

Gambar 9: Cthample of RV appliances powered by the inverter.

5. Penyelenggaraan

Penyelenggaraan berkala memastikan jangka hayat dan prestasi optimum inverter anda.

  • Pastikan inverter bersih dan bebas daripada habuk dan serpihan. Gunakan kain kering untuk pembersihan.
  • Ensure all electrical connections, especially battery terminals, are tight and free from corrosion.
  • Verify that the ventilation openings are not blocked to allow for proper heat dissipation.
  • The inverter supports multiple battery types including GEL, AGM, SLA, FLD, and Lithium (LI). Ensure your battery settings are correctly configured if applicable.

6. Penyelesaian masalah

If you encounter issues with your inverter, refer to the following general troubleshooting steps. For specific error codes or persistent problems, contact Renogy customer support.

  • Tiada Output Kuasa: Check battery connections for tightness and correct polarity. Verify battery voltage is within the inverter's operating range. Ensure the inverter is powered on.
  • Keluaran AC Rendah Voltage: Semak input DC voltage from the battery. Ensure the load is not exceeding the inverter's continuous power rating.
  • Petunjuk lebihan: Reduce the number of connected AC appliances. Disconnect high-power inductive loads that may cause surge spikes.
  • Terlalu panas: Ensure the inverter is in a well-ventilated area. Clear any obstructions from the cooling fans. Reduce the load if operating in high ambient temperatures.

7. Spesifikasi

CiriSpesifikasi
Nama Model3000W Pure Sine Wave Inverter Pro
Nombor Model ItemRIV1230P2-126
Output Kuasa Berterusan3000W
Output Kuasa Puncak6000W
Input DC Voltage12V
Keluaran AC Voltage110V/120V
Kecekapan PenukaranSehingga 90%
Kecekapan beban penuhExceeding 87%
Idle Power Consumption (EcoSleep Mode)< 10W
Herotan Harmonik Jumlah (THD)< 2%
Soket AC2
Blok Terminal AC1
Remote Controller Cable Length16.4 kaki
Dimensi Produk (L x W x H)19.5 x 9.2 x 4.2 inci
Berat Barang16.6 paun
PensijilanUL 458, CSA C22.2 No. 107.1, FCC, ETL
Diagram showing the dimensions of the Renogy 3000W Pure Sine Wave Inverter Pro

Figure 10: Inverter dimensions.

Comparison table of Renogy P2 PRO Series vs. Renogy P2 Series inverters

Figure 11: Feature comparison between Renogy P2 PRO Series and P2 Series inverters.

8. Waranti dan Sokongan

8.1 Waranti

The Renogy 3000W 12V Pro Pure Sine Wave Inverter comes with a 3-year warranty. For any issues encountered within this period, please contact Renogy customer support.

8.2 Sokongan Pelanggan

Renogy is committed to providing excellent customer service. Support includes:

  • 24-hour prompt response to inquiries.
  • Access to local warehouses in the US for efficient service.
  • Professional technical guidance to assist with installation, operation, and troubleshooting.
Icons representing Renogy customer support features: 24-hour response, local warehouses, professional technical guidance, and 15 years of experience

Figure 12: Renogy customer support services.

Dokumen Berkaitan - RIV1230P2-126

Praview Manual Pengguna Inverter Gelombang Sinus Tulen Renogy RIV1230P2-126 Pro 3000W 12V
Manual pengguna yang komprehensif untuk Inverter Gelombang Sinus Tulen Renogy RIV1230P2-126 Pro 3000W 12V dengan Mod EcoSleep, merangkumi ciri, spesifikasi, pemasangan, operasi dan garis panduan keselamatan.
Praview Manual Pengguna Inverter Gelombang Sinus Tulen Renogy 3000W 12V Pro
Manual pengguna yang komprehensif untuk Inverter Gelombang Sinus Tulen Renogy 3000W 12V Pro, yang memperincikan pemasangan, operasi, garis panduan keselamatan, spesifikasi dan penyelesaian masalah. Mempunyai mod EcoSleep untuk kecekapan tenaga.
Praview Manual Pengguna Inverter Gelombang Sinus Tulen Renogy 12V 3000W Pro
Manual pengguna untuk Inverter Gelombang Sinus Tulen Renogy 12V 3000W Pro, yang menyediakan maklumat operasi, penyelenggaraan dan keselamatan penting. Ketahui tentang ciri produk, penafian dan tanda dagangan.
Praview Manual Pengguna Inverter Gelombang Sinus Tulen Renogy 12V dengan Suis Pemindahan
Manual pengguna ini menyediakan arahan komprehensif untuk Inverter Gelombang Sinus Tulen Renogy 12V dengan Suis Pemindahan, tersedia dalam model 1000W, 2000W dan 3000W. Ia merangkumi pemasangan, operasi, langkah berjaga-jaga keselamatan, penyelesaian masalah dan spesifikasi teknikal untuk aplikasi luar grid.
Praview Siri Teras Inverter Gelombang Sinus Tulen Renogy 12V - Spesifikasi dan Ciri Teknikal
Terokai Siri Teras Inverter Gelombang Sinus Tulen Renogy 12V, yang menampilkan penukaran kuasa yang cekap, operasi yang senyap dan ciri keselamatan termaju. Sesuai untuk sistem luar grid. Termasuk spesifikasi teknikal untuk model RIV1210PU-126, RIV1220PU-126 dan RIV1230PU-126.
Praview Manual Pengguna Inverter Gelombang Sinus Tulen Renogy 12V dengan Suis Pemindahan
Manual pengguna yang komprehensif untuk Inverter Gelombang Sinus Tulen Renogy 12V (1000W, 2000W, 3000W) dengan Suis Pemindahan, merangkumi pemasangan, operasi, keselamatan, penyelesaian masalah dan spesifikasi.