The Pedrollo TOP 2 submersible pump is designed for pumping clear water without abrasive particles. This 0.5 HP, 115 Volt pump is engineered for ease of use and reliable operation, featuring total motor cooling and a double mechanical seal on the shaft for enhanced safety and durability.
It is particularly suitable for emergency draining of small flooded areas such as basements, garages, and fountains, as well as for emptying containers or water tanks, and draining water from dishwashers and washing machines.
2. Maklumat Keselamatan
Always prioritize safety when operating electrical equipment, especially with water. Read and understand all instructions before installation and use.
- Sambungan Elektrik: Ensure the power supply matches the pump's specifications (115 Volts). Connect the pump to a properly grounded outlet with a residual current device (RCD) for protection against electric shock.
- Kualiti Air: This pump is designed for clear water. Do not use it for pumping flammable liquids, corrosive chemicals, or water containing large abrasive particles.
- Had Suhu: The maximum liquid temperature for continuous operation is +40 °C. For intermittent use, the pump can handle temperatures up to +40 °C for a maximum period of 3 minutes.
- Pengendalian: Always use the integrated handle for lifting and lowering the pump. Never pull the pump by its power cable or discharge hose.
- Kanak-kanak dan Haiwan Kesayangan: Keep children and pets away from the pump and the area of operation.
- Penyelenggaraan: Putuskan sambungan pam daripada bekalan kuasa sebelum melakukan sebarang penyelenggaraan atau pembersihan.
3. Persediaan dan Pemasangan
Pemasangan yang betul adalah penting untuk prestasi dan jangka hayat pam.
3.1 Membongkar dan Pemeriksaan
Carefully remove the pump from its packaging. Inspect the pump for any signs of damage during transit. Ensure all components, including the 5-meter power cable and integrated float switch, are present.

Pedrollo TOP 2 Submersible Pump packaging and unit.
3.2 Connecting the Discharge Hose
Attach a suitable discharge hose to the pump's outlet. Ensure the connection is secure to prevent leaks during operation. The pump is designed to accommodate standard hose sizes.
3.3 Positioning the Pump
Place the pump on a stable, flat surface in the area to be drained. Ensure the pump is fully submerged in the water before starting. The maximum immersion depth for the TOP 2 model is 3 meters.

Pedrollo TOP 2 Submersible Pump showing the integrated handle and float switch.
3.4 Pelarasan Suis Terapung
The pump features an integrated float switch for automatic start and stop. The float switch activates the pump when the water level rises and deactivates it when the water level drops to a certain point. Ensure the float switch can move freely without obstruction to function correctly.
4. Operasi
Once installed, operating the Pedrollo TOP 2 pump is straightforward.
4.1 Memulakan Pam
After ensuring the pump is correctly positioned and submerged, plug the power cable into a suitable electrical outlet. The integrated float switch will automatically start the pump when the water level reaches the activation point.
4.2 Operasi Automatik
The float switch will automatically turn the pump on and off based on the water level. This feature is ideal for continuous monitoring and draining of fluctuating water levels. The pump will continue to operate until the water level drops to the minimum emptying level of 14 mm from the bottom.
4.3 Menghentikan Pam
To manually stop the pump, simply unplug it from the power outlet. The pump will also stop automatically once the water level falls below the float switch's deactivation point.
5. Penyelenggaraan
Penyelenggaraan tetap memastikan prestasi optimum dan memanjangkan hayat pam anda.
- Pembersihan: Periodically clean the pump's exterior to remove any debris or sediment. Ensure the intake area is clear of obstructions.
- Pemeriksaan Suis Apungan: Regularly check that the float switch moves freely and is not obstructed by debris.
- Pemeriksaan Pendesak: If the pump's performance decreases, inspect the impeller for blockages. The pump can handle solid particles up to Ø 10 mm. Larger particles may cause damage or blockages.
- Storan: If storing the pump for an extended period, especially in freezing conditions, ensure it is completely drained of water to prevent damage. Store in a dry, protected area.
6. Penyelesaian masalah
This section addresses common issues you might encounter with your Pedrollo TOP 2 pump.
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Pam tidak bermula | Tiada bekalan kuasa Float switch not activated Motor terlebih muatan | Periksa sambungan kuasa dan pemutus litar Ensure water level is high enough to activate float Benarkan motor sejuk; semak halangan |
| Aliran air rendah atau tiada | Discharge hose kinked or blocked Pump intake blocked Impeller damaged or clogged | Check and clear hose Clean pump intake screen Disconnect power and inspect/clean impeller |
| Pam berjalan secara berterusan | Suis apungan tersekat dalam kedudukan 'hidup' Aliran masuk air yang berterusan | Check float switch for obstructions Verify the source of water inflow |
Jika masalah berterusan selepas mencuba penyelesaian ini, hubungi kakitangan perkhidmatan yang berkelayakan.
7. Spesifikasi
Technical details for the Pedrollo TOP 2 Submersible Pump.

jarak dekat view of the Pedrollo TOP 2 Submersible Pump, highlighting the technical label.
- model: 2 TERATAS
- Kuasa: 0.5 HP
- Voltage: 115 Volt
- Kedalaman Rendaman Maksimum: 3 meter
- Suhu Cecair Maksimum: +40 °C (for max 3 minutes)
- Sphere Passage (Max Particle Size): Ø 10 mm
- Maximum Emptying Level: 14 mm from the bottom
- Bahan: Besi tuang
- Sumber Kuasa: Electric cable (5m length supplied)
- Komponen yang Disertakan: Integrated float for automatic start/stop
- Dimensi (Pakej): 31.6 x 20.9 x 19.5 cm
- Berat (Pakej): 5.32 kg
- Ketinggian Angkat Maksimum: 3 meter
8. Video Produk Rasmi
No official product videos specifically for the Pedrollo TOP 2 submersible pump from a 'Seller' creator type were found in the provided data. The available video is for a different product (Truper submersible pump) and is therefore not included.
9. Waranti dan Sokongan
For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact Pedrollo customer service directly. Keep your purchase receipt as proof of purchase.