PPOZYLPC S-400-24

PPOZYLPC S-400-24 24V 16.5A 400W Switching Power Supply User Manual

Model: S-400-24

pengenalan

This manual provides detailed instructions for the safe and efficient operation of the PPOZYLPC S-400-24 Switching Power Supply. Designed for various applications requiring a stable 24V DC power source, this unit delivers up to 16.5 Amperes and 400 Watts of power. Please read this manual thoroughly before installation and operation to ensure proper use and to prevent damage or injury.

Maklumat Keselamatan

AMARAN: Vol. Tinggitage! Risiko Renjatan Elektrik!

  • Pemasangan dan penyelenggaraan hendaklah hanya dilakukan oleh kakitangan yang berkelayakan.
  • Ensure the power supply is disconnected from the main AC power source before any wiring or maintenance.
  • Do not operate the unit in wet or high-humidity environments.
  • Pastikan pengudaraan yang betul untuk mengelakkan terlalu panas. Jangan sekat bukaan pengudaraan.
  • Proper grounding is essential for safety. Connect the ground terminal to an earth ground.
  • Jangan buka casinbekalan kuasa. Tiada bahagian yang boleh diservis pengguna di dalamnya.

Produk Selesaiview

The PPOZYLPC S-400-24 is a high-efficiency switching power supply designed to convert AC input to a stable 24V DC output. It features a robust metal casing, built-in cooling fan, and screw terminal connections for secure wiring. This unit is suitable for powering LED lighting, CCTV systems, industrial automation, and other 24V DC devices.

PPOZYLPC S-400-24 Switching Power Supply, top-down view

Rajah 1: Secara keseluruhan view of the PPOZYLPC S-400-24 Switching Power Supply, showing the ventilation grille and terminal block.

Persediaan dan Pemasangan

1. Input Voltage Pemilihan

The S-400-24 power supply supports both 110V AC and 220V AC input. A voltage selector switch is located on the side of the unit. Ensure this switch is set to the correct voltage for your region before connecting to AC power. vol. salahtage selection can cause severe damage to the unit and connected devices.

sebelah view of PPOZYLPC S-400-24 showing model label and voltage suis pemilih

Rajah 2: Sisi view of the power supply, highlighting the model information and the input voltage selector switch (usually a small red switch).

2. Pemasangan

Mount the power supply in a stable, well-ventilated area. Ensure there is adequate space around the unit for airflow, especially around the cooling fan and ventilation grilles. Use appropriate screws to secure the unit through its mounting tabs.

3. Sambungan Pendawaian

Refer to the terminal block for proper wiring. All connections should be made using appropriate gauge wires, securely fastened to prevent loose connections.

Depan view of PPOZYLPC S-400-24 showing terminal block connections

Rajah 3: Depan view of the power supply, detailing the screw terminal block for input and output connections.

Terminal Block Description:

  • L, N: AC Power Input (Live and Neutral). Connect your main AC power source here.
  • Tanah: Earth Ground. Connect to a reliable earth ground for safety.
  • -V (COM): DC Output Negative. Connect the negative terminal of your 24V DC load.
  • +V: DC Output Positive. Connect the positive terminal of your 24V DC load.
  • ADJ: Keluaran Voltage Adjustment. Use a small screwdriver to fine-tune the output voltage within a small range (typically ±10%).

CAUTION: Double-check all wiring connections before applying power. Incorrect wiring can lead to damage, fire, or electric shock.

Arahan Operasi

  1. After completing all wiring and ensuring the input voltage selector is correct, connect the power supply to the AC mains.
  2. The LED indicator (if present) on the unit should illuminate, indicating power is on.
  3. Sahkan keluaran voltage using a multimeter at the +V and -V terminals before connecting your load. Adjust the ADJ potentiometer if necessary.
  4. Connect your 24V DC load to the +V and -V terminals.
  5. The power supply features built-in protections against overcurrent, overvoltage, and short circuits. In case of a fault, the unit may shut down automatically. Disconnect power, resolve the issue, and then reconnect power.

Penyelenggaraan

The PPOZYLPC S-400-24 is designed for reliable operation with minimal maintenance. Follow these guidelines:

  • Pembersihan: Periodically clean the exterior of the unit, especially the ventilation grilles, to prevent dust buildup. Use a soft, dry cloth. Do not use liquid cleaners.
  • Pengudaraan: Ensure that the cooling fan and ventilation openings remain unobstructed at all times. Poor ventilation can lead to overheating and reduced lifespan.
  • Sambungan: Periodically check all wiring connections to ensure they remain tight and secure. Loose connections can cause intermittent operation or overheating.
Atas view of PPOZYLPC S-400-24 showing cooling fan and caution label

Rajah 4: Atas view of the power supply, showing the integrated cooling fan and important caution labels regarding proper usage.

Menyelesaikan masalah

MasalahKemungkinan PuncaPenyelesaian
Tiada keluaran voltage / LED off
  • Tiada kuasa input AC
  • Input salah voltage pemilihan
  • Fius putus (dalaman)
  • Pendawaian yang rosak
  • Check AC power source and connections.
  • Sahkan input voltage kedudukan suis pemilih.
  • Contact qualified service personnel for fuse replacement.
  • Inspect all wiring for loose or incorrect connections.
Keluaran voltage unstable or too low
  • Keadaan beban berlebihan
  • Sambungan longgar
  • ADJ potentiometer misadjusted
  • Reduce load or use a higher-rated power supply.
  • Periksa dan ketatkan semua sambungan pendawaian.
  • Adjust ADJ potentiometer with a multimeter.
Unit terlalu panas
  • Pengudaraan yang tidak mencukupi
  • Keadaan beban berlebihan
  • Kipas rosak
  • Pastikan aliran udara yang mencukupi di sekitar unit.
  • Kurangkan beban.
  • Check if the fan is spinning freely. If not, contact support.

Spesifikasi

ParameterNilai
Nombor ModelS-400-24
JenamaPPOZYLPC
Keluaran Voltage24V DC
Arus Keluaran16.5A
Kuasa Keluaran400W
Input Voltage110V / 220V AC (selectable)
Berat Barang30 Gram (lebih kurang 1.06 auns)
PengeluarPPOZYLPC

Catatan: Spesifikasi boleh berubah tanpa notis.

Waranti dan Sokongan

For warranty information or technical support, please refer to the documentation provided with your purchase or contact your retailer. As specific warranty terms are not provided in this manual, please retain your proof of purchase for any warranty claims.

Dokumen Berkaitan - S-400-24

Praview Switching Power Supply User Manual - Cazitog S-400-13.8
User manual for the Cazitog S-400-13.8 switching power supply, covering product usage, installation, operation, limitations, safety warnings, and applicable regulations.
Praview RHINO PSR-24-240-3 Power Supply: Installation Guide & Technical Data
Comprehensive installation instructions and technical specifications for the RHINO PSR-24-240-3 24VDC, 10A, 240W switching power supply. Learn about safety, mounting, connections, and performance.
Praview RHINO PSR-24-120 Power Supply Installation Guide & Technical Data
Comprehensive installation instructions and technical specifications for the RHINO PSR-24-120 24VDC 5A power supply by Automation Direct. Learn about safety, mounting, wiring, and performance.
Praview MJJC LED Power Supply User Manual - 60W to 400W Models
Comprehensive user manual for MJJC LED power supplies, detailing specifications, features, and wiring diagrams for models ranging from 60W to 400W with 12V and 24V DC outputs. Includes input voltage, output current, dimensions, and connection instructions for various configurations.
Praview RHINO PSR-24-240 Power Supply Installation Instructions and Technical Data
Detailed installation instructions, safety guidelines, and technical specifications for the AutomationDirect RHINO PSR-24-240 24VDC, 10A, 240W power supply. Includes mounting, wiring, and performance data.
Praview Danfoss SonoMeter 40 Installation Guide: 24V Power Supply and 230V Transformer
Installation guide for the Danfoss SonoMeter 40 energy meter, detailing the setup and wiring of the 24V power supply module and the 230V AC transformer.