pengenalan
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Remco 5500 Series ProFlo Demand Pump, model 5537-1E1-65C. This professional-grade pump is designed for various agricultural and industrial spraying applications, offering reliable performance and durability.
Maklumat Keselamatan
Please read and understand all safety instructions before operating the pump. Failure to follow these guidelines may result in injury or damage to the equipment.
- Keselamatan Elektrik: Ensure the pump is connected to a 115 VAC power source. Use appropriate wiring (14 AWG leads) and ensure all electrical connections are secure and protected.
- Had Suhu: The maximum liquid temperature should not exceed 140°F (60°C). The maximum motor temperature is 180°F (82°C), but for optimal performance and motor life, the motor surface temperature should not exceed 150°F (66°C). The motor is not equipped with thermal protection.
- Keserasian Kimia: This pump is compatible with common agricultural chemicals such as herbicides, fertilizers, and insecticides. Always verify chemical compatibility before use to prevent damage to pump components.
- Tekanan: The pump operates at 60 PSI (4.1 Bar) on demand. Ensure your system can handle this pressure.
- Pemasangan: Securely mount the pump using the integrated bracket to prevent vibration and movement during operation.
Produk Selesaiview
The Remco 5500 Series ProFlo Demand Pump is a robust 5-chamber diaphragm pump designed for demanding applications. It features a sealed 115 VAC electric motor and durable components for long, continuous duty cycles.

Rajah 1: Remco 5500 Series ProFlo Demand Pump. This image displays the pump with its silver motor housing, black pump head, and black mounting bracket. A label on the motor housing indicates the model number 5537-1E1-65C, flow rate of 5.3 GPM, 115 VAC voltage, and 60 PSI pressure rating. A power cord is visible extending from the motor.
Ciri-ciri Utama:
- Professional Grade Quality
- 5.3 GPM (20.06 LPM) Flow Rate
- 60 PSI (4.1 Bar) On-Demand Operation
- Dibuat di USA
- Kord Kuasa 6 kaki
- Chemically compatible with common agricultural chemicals
- 100% Factory Tested
- Completely Sealed Motor
- Low Heat and Power Consumption
- Superior Vertical Priming (up to 14 feet / 4.0 meters)
Persediaan
- Pemasangan: Securely fasten the pump to a stable surface using the integrated mounting bracket. Ensure the pump is positioned to allow for proper ventilation and access for connections.
- Sambungan Paip: Connect your inlet and outlet lines to the 1/2" FNPT threaded ports. Use appropriate fittings and sealants to ensure leak-free connections. The pump is self-priming up to 14 feet (4.0 meters) vertically.
- Sambungan Elektrik: Connect the 14 AWG wire leads to a dedicated 115 VAC power supply. Ensure the power source is fused and protected according to local electrical codes. Verify correct polarity.
- System Priming: Before initial operation, ensure the pump and lines are filled with liquid to facilitate priming.
Operasi
The Remco 5500 Series pump operates in demand mode, meaning it will run when there is a demand for fluid and shut off when the system pressure reaches 60 PSI. This allows for efficient operation and reduced power consumption.
- Memulakan Pam: Once all connections are secure and the system is primed, apply power to the pump. The pump will start when a flow demand is detected.
- Pemantauan: Observe the pump during operation for any unusual noises, leaks, or excessive heat.
- Kitaran Tugas: The pump is designed for intermittent duty cycles. While it can withstand long cycles, continuous operation at maximum load may reduce its lifespan. Monitor motor temperature to ensure it stays below 150°F (66°C).
- Dry Run Capability: The pump has dry run capability, meaning it can operate without fluid for short periods without damage. However, prolonged dry running should be avoided.
Penyelenggaraan
Regular maintenance ensures the longevity and optimal performance of your Remco pump.
- Pembersihan: Periodically inspect the pump for dirt, debris, or chemical residue. Clean the exterior with a damp kain.
- Sambungan: Regularly check all plumbing and electrical connections for tightness and signs of wear or corrosion.
- Musim sejuk: If operating in freezing conditions, ensure the pump and lines are completely drained or protected with appropriate antifreeze solutions to prevent damage.
- Chemical Residue: After using corrosive or sticky chemicals, flush the pump with clean water to prevent buildup and ensure proper valve function.
Menyelesaikan masalah
This section provides general guidance for common issues. For complex problems, contact Remco customer support.
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Pam tidak bermula | No power, loose electrical connection, faulty switch. | Check power supply, verify connections, test switch. |
| Aliran atau tekanan rendah | Clogged inlet filter, air leak in suction line, worn diaphragm, low voltage. | Clean filter, check for leaks, inspect diaphragm, verify voltage. |
| Pam berjalan secara berterusan | Leak in system, faulty pressure switch, air in system. | Check for leaks, inspect pressure switch, bleed air from system. |
| Bunyi atau getaran yang berlebihan | Loose mounting, cavitation (air in line), debris in pump. | Tighten mounting, ensure proper priming, inspect for debris. |
Spesifikasi
| Jenama | Remco |
| Nombor Model | 5537-1E1-65C |
| Jenis Pam | 5 Chamber Diaphragm Pump |
| Mod | Permintaan |
| Voltage | 115 VAC |
| Kadar Aliran Maksimum | 5.3 GPM (20.06 LPM) |
| Penetapan Tekanan | 60 PSI (4.1 Bar) |
| Fluid Port | 1/2" FNPT threaded Ports |
| Injap | Viton |
| Diafragma | Santoprene |
| Dawai Lead | 14 AWG - 6" or 12" 2-Pin Mold / Custom Connection |
| Mementingkan Diri | Up to 14' (4.0 m) vertically |
| Kitaran Tugas | Selang-seli |
| Dry Run Capability | ya |
| Suhu Cecair Maks | 140°F (60°C) |
| Max Motor Temperature | 180°F (82°C) (Surface temp should not exceed 150°F / 66°C) |
| UPC | 816624019041 |
| Komponen yang Disertakan | Pam |
Waranti dan Sokongan
For information regarding product warranty, technical support, or replacement parts, please contact Remco directly through their official website or customer service channels. Keep your purchase receipt and model number (5537-1E1-65C) handy for faster service.
You can visit the Remco store on Amazon for more information: Remco Store