All States 149529

All States Condenser to Receiver Drier Hose Instruction Manual

Model: 149529 | Replaces Ag-Chem OEM Part: AG122067

1. Pengenalan

This manual provides essential information for the proper installation, operation, and maintenance of your All States Condenser to Receiver Drier Hose, Model 149529. This product is designed as a direct replacement for Ag-Chem OEM part number AG122067. Please read these instructions carefully before proceeding with installation or maintenance to ensure safe and effective use.

2. Maklumat Keselamatan

WARNING: Automotive air conditioning systems contain refrigerants under high pressure. Improper handling can cause serious injury, including frostbite, chemical burns, or blindness. Always wear appropriate personal protective equipment (PPE), including safety glasses and gloves, when working on AC systems.

3. Produk Lebihview

The All States Condenser to Receiver Drier Hose (Model 149529) is a critical component in the air conditioning system of Ag-Chem equipment, facilitating the transfer of refrigerant between the condenser and the receiver drier. This hose is engineered to meet or exceed OEM specifications, ensuring reliable performance and a precise fit.

All States Condenser to Receiver Drier Hose with angled and straight fittings

This image displays the All States Condenser to Receiver Drier Hose. The hose features a black flexible section, with a 90-degree angled metal fitting on the left and a straight metal fitting on the right. Both fittings are secured to the hose ends with blue clamp assemblies, indicating a robust connection for AC system applications.

4. Persediaan dan Pemasangan

4.1 Pemeriksaan Pra-Pemasangan

4.2 Prosedur Pemasangan

  1. Keluarkan Hos Lama: Carefully disconnect and remove the old condenser to receiver drier hose. Be prepared for any residual refrigerant or oil.
  2. Sambungan Bersih: Thoroughly clean the mating surfaces on the condenser and receiver drier to ensure a proper seal. Remove any old O-rings or debris.
  3. Install New O-Rings: Apply a thin coat of appropriate AC system lubricant (e.g., PAG oil for R-134a systems) to new O-rings. Install the O-rings onto the fittings of the new hose. Do not reuse old O-rings.
  4. Sambungkan Hos: Carefully align the new hose with the condenser and receiver drier connections. Hand-tighten the fittings to ensure they are not cross-threaded.
  5. Torque Fittings: Using a torque wrench, tighten the fittings to the manufacturer's specified torque values. Overtightening can damage fittings and cause leaks; undertightening can also lead to leaks. Consult your equipment's service manual for specific torque specifications.
  6. Mengosongkan dan Mengisi Semula Tenaga: After installation, the AC system must be evacuated using a vacuum pump to remove air and moisture. Once evacuated, recharge the system with the correct type and amount of refrigerant and compressor oil according to the equipment manufacturer's specifications.
  7. Ujian Kebocoran: Perform a thorough leak test using an electronic leak detector or UV dye to confirm all connections are sealed properly.

5. Arahan Operasi

Once the All States Condenser to Receiver Drier Hose is correctly installed and the AC system has been evacuated and recharged, the system should operate as designed. Monitor the AC system's performance, ensuring consistent cooling and no unusual noises or odors. The hose itself is a passive component and does not require specific operating instructions beyond proper installation and system integrity.

6. Penyelenggaraan

Regular inspection of the AC system, including the condenser to receiver drier hose, is crucial for longevity and performance.

7. Penyelesaian masalah

If you experience issues with your AC system after installing the hose, consider the following common problems:

simptom Kemungkinan Punca Tindakan
Kebocoran Bahan Penyejuk Improperly torqued fittings, damaged O-rings, hose damage. Perform a leak test. Re-torque fittings to specification. Replace O-rings if necessary. Replace hose if damaged.
Prestasi Penyejukan yang Lemah Low refrigerant charge, air/moisture in system, other AC component failure. Check refrigerant levels. Evacuate and recharge system. Consult a technician for further diagnosis.
Hose Kinked or Restricted Laluan yang tidak betul semasa pemasangan. Inspect hose routing. Re-route or replace hose if permanently kinked.

For complex issues or if troubleshooting steps do not resolve the problem, it is recommended to consult a qualified automotive AC technician.

8. Spesifikasi

9. Waranti dan Sokongan

For information regarding the product warranty, please refer to the warranty documentation provided by All States or the retailer from whom the product was purchased. For technical support or further assistance, please contact the All States customer service department or your authorized dealer.

Dokumen Berkaitan - 149529

Praview Earthwise GH-001 Automatic Hose Reel Owner's Manual and Instructions
Owner's manual for the Earthwise GH-001 Automatic Hose Reel. Provides detailed installation, usage, safety, and warranty information for this 130-foot hose reel with a 7-setting metal nozzle and quick connect adapters.
Praview Earthwise GH-001 Automatic Hose Reel Owner's Manual and Warranty Information
Comprehensive owner's manual and warranty policy for the Earthwise GH-001 Automatic Hose Reel, featuring a 130-foot hose, premium 7-setting metal hose nozzle, and quick connect adapters. Includes product details and support information from American Lawn Mower Company.
Praview Mamalia Sempadan Mexico Amerika Syarikat: Katalog Saintifik
Temui biodiversiti yang kaya di wilayah sempadan AS-Mexico melalui Buletin Institusi Smithsonian 1907 Edgar Alexander Mearns 56. Katalog komprehensif ini memperincikan spesies mamalia, sejarah semula jadi dan flora serantau, menawarkan kajian asas dalam zoologi dan botani.
Praview Case IH & International Harvester Tractor Parts Catalog | All States Ag Parts
Find a wide selection of new and used tractor parts, engine overhaul kits, shop manuals, and accessories for Case IH, International Harvester, and David Brown equipment. All States Ag Parts offers comprehensive solutions for agricultural machinery maintenance and repair.
Praview Prosiding Muzium Negara Amerika Syarikat, Vol. 121: Semakan Melanotus Click Beetles & Soldier Fly Larva
Jilid 121 Prosiding Muzium Negara Amerika Syarikat (1967) menampilkan semakan komprehensif kumbang klik Melanotus Amerika Utara oleh Quate dan Thompson, bersama penyelidikan tentang larva Soldier Fly oleh McFadden, yang menawarkan cerapan taksonomi dan biologi yang penting.
Praview Infantry Training and Readiness Manual - NAVMC 3500.44D
Official manual detailing training standards, regulations, and policies for the United States Marine Corps' Infantry occupational field. Covers collective and individual training events, mission essential tasks, and readiness assessment for infantry Marines.