Qoltec 50900

QOLTEC 50900 Three Phase Electronic Energy Consumption Meter User Manual

1. Pengenalan

This manual provides detailed instructions for the installation, operation, and maintenance of the QOLTEC 50900 Three Phase Electronic Energy Consumption Meter. This device is designed for measuring active energy consumption in three-phase, four-wire AC circuits. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. Maklumat Keselamatan

AMARAN: Installation and maintenance of this device must be performed by qualified personnel only. Failure to follow these instructions can result in electric shock, fire, or serious injury.

3. Produk Lebihview

The QOLTEC 50900 is a compact, DIN rail mountable electronic energy meter designed for accurate measurement of three-phase energy consumption. It features an LCD display for clear readings and a pulse output for remote monitoring.

QOLTEC 50900 Energy Meter with dimensions and key features

Figure 3.1: QOLTEC 50900 Energy Meter showing dimensions (75mm x 92mm x 76mm) and key features like Three Phase Type, 230V Rated Voltage, 1.0 Precision Class, and LCD Display.

Ciri-ciri Utama:

4. Spesifikasi

ParameterNilai
Model50900
Dinilai Voltage3x230/400V AC
Nilai Semasa3x10(100)A
Kekerapan50Hz
Kelas Ketepatan1.0
PaparanLCD
Keluaran Nadi400imp/kWj
PemasanganDIN Rail (4P)
Dimensi (W x H x D)75 x 92 x 76 mm
Berat badan100 g
bahanAkrilik

5. Persediaan dan Pemasangan

The QOLTEC 50900 meter is designed for standard 35mm DIN rail mounting. Ensure the installation location is dry, well-ventilated, and free from excessive vibration or electromagnetic interference.

5.1 Pemasangan

  1. Cari rel DIN 35mm yang sesuai di dalam panel elektrik anda.
  2. Align the meter's DIN rail clip with the rail.
  3. Tekan meter dengan kuat pada rel sehingga ia klik pada tempatnya.
QOLTEC 50900 Energy Meter mounted on a DIN rail

Figure 5.1: The QOLTEC 50900 meter securely mounted on a DIN rail, showing its compact form factor.

5.2 Sambungan Pendawaian

PENTING: All wiring must comply with local electrical codes and regulations. Ensure power is OFF before making any connections.

  1. Identify the input (IN) and output (OUT) terminals on the meter.
  2. Connect the incoming three-phase lines (L1, L2, L3) and Neutral (N) to the corresponding IN terminals (typically 5, 6, 7, 8).
  3. Connect the outgoing three-phase lines (L1, L2, L3) and Neutral (N) to the corresponding OUT terminals (typically 1, 2, 3, 4).
  4. Pastikan semua sambungan adalah ketat dan selamat untuk mengelakkan sentuhan longgar dan terlalu panas.
Wiring diagram for QOLTEC 50900 Energy Meter showing input and output terminals

Rajah 5.2: Sisi view of the meter showing the wiring diagram for input (IN) and output (OUT) connections for L1, L2, L3, and Neutral.

Front and terminal views of QOLTEC 50900 Energy Meter

Rajah 5.3: Depan view of the meter with its LCD display and a separate view of the terminal block for wiring connections.

6. Arahan Operasi

Once properly installed and powered, the QOLTEC 50900 meter will automatically begin measuring energy consumption.

6.1 Paparan LCD

The LCD displays the total active energy consumption in kilowatt-hours (kWh). The display is continuous and does not require any button presses for basic reading.

Close-up of QOLTEC 50900 LCD display showing energy reading

Rajah 6.1: Jarak dekat view of the LCD display showing an example energy reading in kWh.

6.2 Keluaran Nadi

The meter features a pulse output (400imp/kWh) which can be used to connect to external monitoring systems for remote data collection. Refer to the external system's documentation for connection details.

7. Penyelenggaraan

The QOLTEC 50900 energy meter is designed for maintenance-free operation under normal conditions.

8. Penyelesaian masalah

If you encounter issues with your QOLTEC 50900 meter, refer to the following common problems and solutions:

MasalahKemungkinan PuncaPenyelesaian
Tiada paparan/Meter tidak dapat dihidupkanNo power supply; Incorrect wiring; Blown fuse in circuitCheck power supply to the meter. Verify wiring connections. Check circuit breaker/fuse.
Incorrect energy readingIncorrect wiring; Faulty meterVerify wiring connections against the diagram. If wiring is correct, contact support.
Pulse output not workingIncorrect connection to external system; Faulty meterCheck pulse output wiring to the external system. Consult external system's manual. If issue persists, contact support.

If the problem persists after attempting these solutions, please contact Qoltec customer support.

9. Waranti dan Sokongan

Qoltec products are manufactured to high-quality standards. For warranty information and technical support, please refer to the warranty card included with your product or visit the official Qoltec webtapak. Simpan resit pembelian anda sebagai bukti pembelian.

Dokumen Berkaitan - 50900

Praview Amaran Keselamatan untuk Penggunaan: Meter Penggunaan Elektrik Rel DIN Qoltec (TUYA)
Amaran dan langkah berjaga-jaga keselamatan yang komprehensif untuk pemasangan, penggunaan, penyelenggaraan dan penyimpanan meter penggunaan elektrik rel DIN (TUYA) Qoltec untuk memastikan keselamatan pengguna dan jangka hayat produk, mematuhi peraturan EU.
Praview Qoltec DIN Rail Electricity Consumption Meter Safety Warnings and Precautions
Comprehensive safety warnings and precautions for Qoltec DIN rail electricity consumption meters, covering electrical risks, overloading, overheating, misuse, environmental factors, maintenance, and emergency procedures.
Praview Qoltec DIN Rel (TUYA) Elektriarvesti Ohutusjuhised
Täielikud ohutusjuhised ja ettevaatusabinõud Qoltec DIN Rail (TUYA) tüüpi elektriarvestite paigaldamiseks, kasutamiseks ja hooldamiseks. Tootja: NTEC sp. z oo
Praview Qoltec 50882 Single-phase Smart Energy Meter with Wi-Fi - Operating Instructions
Operating instructions for the Qoltec Model 50882, a single-phase smart energy meter with Wi-Fi for DIN rail mounting. Features include remote monitoring, kWh measurement, and compliance with industry standards.
Praview Qoltec Three Phase Smart Din Rail Energy Meter wi-fi User Manual
User manual for the Qoltec Three Phase Smart Din Rail Energy Meter wi-fi with 7 modules, model 50883. Includes technical parameters, dimensions, connection instructions, and warranty information.
Praview Garis Panduan Keselamatan dan Penggunaan Qoltec DIN Rail Energy Meter (TUYA).
Langkah berjaga-jaga keselamatan yang komprehensif dan garis panduan penggunaan untuk Qoltec DIN Rail Energy Meter (TUYA). Ketahui tentang bahaya elektrik, risiko beban lampau, terlalu panas, pemasangan yang betul, penyelenggaraan dan prosedur kecemasan untuk memastikan pemantauan penggunaan tenaga yang selamat dan tepat.