Rebel RB-4013

Rebel POWER-1000 Pure Sine Wave Inverter User Manual

Model: RB-4013

1. Pengenalan

Thank you for choosing the Rebel POWER-1000 Pure Sine Wave Inverter. This device is designed to convert 12V DC power from a battery into 230V AC pure sine wave power, suitable for a wide range of electronic devices. It also features an integrated battery charging function. To ensure safe and efficient operation, please read this manual thoroughly before installation and use, and retain it for future reference.

2. Produk Lebihview

The Rebel POWER-1000 inverter is a versatile power solution offering reliable performance. Key features include:

  • Output Gelombang Sinus Tulen: Ensures safe and stable operation for sensitive electronics.
  • Integrated Charging Function: Functions as an emergency power device with a built-in rectifier and inverter.
  • Perlindungan Komprehensif: Includes safeguards against overload, short circuit, overvoltage, undervoltage, dan terlalu panas.
  • Paparan led: Provides real-time status information for easy monitoring.
Depan view of the Rebel POWER-1000 Pure Sine Wave Inverter

Rajah 2.1: Depan view of the Rebel POWER-1000 Inverter, showing the LED display and power button.

3. Persediaan dan Pemasangan

Proper installation is crucial for the safe and effective operation of your inverter. Please follow these steps carefully.

3.1 Langkah Keselamatan

  • Ensure the installation area is well-ventilated and free from flammable materials.
  • Do not expose the inverter to water or excessive humidity.
  • Always disconnect the battery before making any connections to prevent electric shock.
  • Gunakan peralatan pelindung diri (PPE) yang sesuai semasa pemasangan.

3.2 Menyambungkan Penyongsang

Refer to the diagrams below for connection points.

belakang view of the Rebel POWER-1000 Inverter with AC input, outputs, and battery terminals

Rajah 3.1: Belakang view of the inverter showing AC input, output sockets, and battery terminals.

Close-up of the rear output sockets and AC input on the Rebel POWER-1000 Inverter

Rajah 3.2: Terperinci view of the AC output sockets and AC input with circuit breaker.

  1. Sambungan Bateri: Connect the 12V DC battery to the designated battery terminals on the inverter (red for positive, black for negative). Ensure a secure and tight connection.
  2. Sambungan Input AC: Plug the inverter's AC input cable into a standard 230V AC wall outlet. This connection is used for the battery charging function.
  3. Sambungan Output AC: Connect your 230V AC appliances to the output sockets on the rear of the inverter.

3.3 Memasang Penyongsang

The inverter can be wall-mounted using the integrated mounting points.

Bawah view of the Rebel POWER-1000 Inverter showing wall-mounting brackets

Rajah 3.3: Bawah view of the inverter, illustrating the wall-mounting brackets.

Use appropriate screws and anchors for your wall type to securely fasten the inverter. Ensure sufficient clearance around the unit for ventilation.

4. Arahan Operasi

4.1 Menghidupkan/Mematikan

  • To power on the inverter, press and hold the power button on the front panel until the LED display illuminates.
  • Untuk mematikan kuasa, tekan dan tahan butang kuasa sekali lagi sehingga paparan dimatikan.

4.2 Maklumat Paparan LED

The LED display provides critical information about the inverter's status, including input voltage, keluaran voltage, frequency, battery charge level, and any active warnings or errors.

4.3 Mod Penyongsang

When the inverter is powered on and connected to a 12V DC battery, it will convert the DC power to 230V AC for your connected appliances. Ensure the total wattage of your appliances does not exceed the inverter's rated power of 700W.

4.4 Fungsi Pengecasan

When the inverter is connected to both a 12V DC battery and a 230V AC input, it will automatically begin charging the battery. The LED display will indicate the charging status. The maximum charging current is 10A.

5. Penyelenggaraan

Penyelenggaraan berkala membantu memastikan jangka hayat dan prestasi optimum inverter anda.

  • Pembersihan: Bersihkan bahagian luar penyongsang secara berkala dengan kain kering dan lembut. Pastikan bukaan pengudaraan bebas daripada habuk dan serpihan. Jangan gunakan pembersih cecair.
  • Sambungan: Regularly check all electrical connections (battery, AC input, AC output) to ensure they are secure and free from corrosion.
  • Persekitaran: Operate the inverter within the specified temperature and humidity ranges. Avoid direct sunlight and extreme temperatures.

6. Penyelesaian masalah

If you encounter issues with your Rebel POWER-1000 inverter, refer to the following common problems and solutions:

MasalahKemungkinan PuncaPenyelesaian
Inverter tidak dihidupkanBateri rendah voltage, loose battery connection, power button not pressed correctly.Semak bateri voltage, ensure battery connections are secure, press and hold power button.
Tiada output ACOverload, short circuit, overheating, battery low.Reduce connected load, check for short circuits, allow inverter to cool, charge battery.
Bateri tidak dicasAC input not connected, AC input power issue.Ensure AC input cable is securely plugged in, check wall outlet for power.
Error code on LED displayIndicates specific fault (e.g., overvoltage, undervoltage, overload).Consult the display for the specific error and refer to the relevant section of this manual or contact support.

Jika masalah berterusan selepas mencuba penyelesaian ini, sila hubungi sokongan pelanggan.

7. Spesifikasi

Detailed technical specifications for the Rebel POWER-1000 Inverter (Model RB-4013):

ParameterNilai
Kuasa Dinilai700 W
Jenis Bateri12 V DC
Vol Bateri Maksimumtage15 V DC
Input Voltage Julat (AC)180 ~ 275 V AC
Kekerapan Input45 ~ 60 Hz
Keluaran Voltage Julat (AC)230 V AC +/-8 %
Kekerapan Output50/60 Hz +/-0.5 Hz
Keluaran Voltage GelombangGelombang Sinus Tulen
Kecekapan Output (DC ke AC)>= 85 %
Arus Pengecasan BateriMaks. 10 A
Masa Bertukar<= 4 ms
Ciri-ciri PerlindunganOverload, Short Circuit, Overvoltage, Undervoltage, Terlalu Panas
Suhu Operasi0-40 °C
Kelembapan Operasi10-90 %
Dimensi (L x W x H)240 x 325 x 138 mm
Berat badan4.7 kg
Nombor ModelRB-4013
JenamaPemberontak

8. Waranti dan Sokongan

Warranty information for the Rebel POWER-1000 Inverter is not provided in this document. Please refer to your purchase documentation or contact your retailer for details regarding warranty coverage.

For technical support or further assistance, please contact the vendor or manufacturer directly using the contact information provided at the point of purchase.

Dokumen Berkaitan - RB-4013

Praview Manual de Use Rebel RB-4026, RB-4027, RB-4028 - Invertor de Putere
Anda telah melengkapkan penggunaan kawasan, memasang dan mengendalikan invertorului putere Rebel dengan sinusoida dan berfungsi sebagai penjagaan. Sertakan arahan tandatangan, pemilihan bateri dan teknik spesifikasi.
Praview Manual Pengguna Bekalan Kuasa Tidak Terganggu UPS Rebel RB-4020-5
Manual pengguna untuk model Rebel Uninterruptible Power Supply (UPS) RB-4020, RB-4021, RB-4022, RB-4023, RB-4024, RB-4025. Termasuk amaran keselamatan, pengenalan, spesifikasi, penyelesaian masalah dan maklumat pelupusan yang betul.
Praview Rebel Digital Multimeter MIE-RB-33B, C, D User Manual
User manual for the Rebel Digital Multimeter models MIE-RB-33B, MIE-RB-33C, and MIE-RB-33D. Includes safety instructions, product description, operation guide, specifications, and maintenance information.
Praview Manual Pengguna Pemutar Skru Tanpa Kord Rebel RB-1003
Get detailed instructions and safety information for the Rebel RB-1003 Cordless Screwdriver. This user manual covers operation, maintenance, and troubleshooting for your Rebel tools.
Praview Manual Pengguna Rebel Power Inverter
Manual pengguna yang komprehensif untuk Penyongsang Kuasa Rebel, meliputi pemasangan, operasi, keselamatan, penyelesaian masalah dan spesifikasi untuk model URZ3160-62, URZ3164-65, URZ3167-68.
Praview Rebel MIE-RB-55 Digital Multimeter User Manual
Comprehensive user manual for the Rebel MIE-RB-55 Digital Multimeter, covering safety instructions, product description, operation, maintenance, and technical specifications.