The FireAngel FA6813 Carbon Monoxide (CO) Detector is designed to provide early warning of dangerous carbon monoxide levels in your home. This device utilizes an advanced electrochemical sensor to accurately detect CO gas, which is colorless, odorless, and highly toxic. It is a crucial safety device for any household.

This model is designed to replace previous FireAngel CO-9B and CO-9X models, offering enhanced features and reliability. It is powered by 2 AA batteries, ensuring continuous operation even during power outages.

FireAngel FA6813 Carbon Monoxide Detector front view

Rajah 1: Depan view of the FireAngel FA6813 Carbon Monoxide Detector.

FireAngel FA6813 Carbon Monoxide Detector with packaging highlighting features

Figure 2: The FA6813 detector with its packaging, emphasizing its 10-year sensor life, 85 dB(A) alarm, and included AA batteries.

2. Maklumat Keselamatan Penting

WARNING: This device detects carbon monoxide gas. It is not designed to detect smoke, fire, or other gases. Carbon monoxide is a silent killer; it is invisible, odorless, and potentially fatal.

In Case of a CO Alarm:

  1. Ventilasi: Immediately open all doors and windows to air out the premises. Turn off all combustion appliances (e.g., furnaces, water heaters, gas stoves).
  2. Pindahkan: Leave the building immediately. Ensure everyone, including pets, is out of the affected area.
  3. Call for Help: From a safe location outside the building, contact your gas supplier or emergency services. Do not re-enter the premises until it has been declared safe by a qualified professional.
  4. Jangan Guna Semula: Do not use any combustion appliances again until they have been inspected and verified safe by a qualified technician.
FireAngel FA6813 Carbon Monoxide Detector side view with safety information

Rajah 3: Sisi view of the FA6813, emphasizing its role in domestic safety and the properties of carbon monoxide.

3. Kandungan Pakej

Sila tandakan kotak untuk memastikan semua komponen ada:

  • FireAngel Carbon Monoxide Alarm (FA6813)
  • 2 x Bateri AA
  • Manual Pengguna

4. Persediaan dan Pemasangan

4.1 Pemasangan Bateri

The FA6813 detector operates on 2 AA batteries. These are included in the package. To install:

  1. Cari petak bateri di bahagian belakang unit.
  2. Buka penutup petak.
  3. Insert the 2 AA batteries, ensuring correct polarity (+ and -).
  4. Tutup penutup petak bateri dengan selamat.

4.2 Penempatan dan Pemasangan

The FA6813 is designed for versatile placement, suitable for both home use and travel. It can be wall-mounted or placed freestanding on a flat surface.

  • Pemasangan Dinding: The device comes with an integrated mounting bracket and screws. Choose a location according to local regulations and manufacturer guidelines (typically near combustion appliances but not directly above them, and at breathing height). Mark the screw positions, drill pilot holes, insert wall plugs if necessary, and secure the bracket. Slide the detector onto the bracket.
  • Berdiri bebas: For portable use or temporary placement, the detector can stand on its own. Place it on a stable, flat surface where it will not be easily knocked over.
FireAngel FA6813 Carbon Monoxide Detector in a travel setting

Figure 4: The FA6813 detector shown in a travel context, highlighting its portability and integrated mounting support for optional wall installation.

5. Arahan Operasi

5.1 Operasi Biasa

Once batteries are installed, the device will perform a self-test and then enter normal monitoring mode. A small LED indicator may flash periodically to confirm it is active and monitoring.

5.2 Fungsi Butang Ujian

The large test button on the front of the detector serves multiple purposes:

  • Safety Test: Press the test button briefly to verify the proper functioning of the detector. A loud, sharp audible signal and 4 flashes of the red LED will confirm the alarm is working correctly. Perform this test regularly (e.g., weekly or monthly).
  • Sound Level Adjustment (Sound Test): Hold the test button down to cycle through different sound levels for the test alarm, allowing you to choose a comfortable volume.

5.3 Petunjuk Penggera

When dangerous levels of carbon monoxide are detected, the FA6813 will alert you with:

  • Penggera yang boleh didengar: 4 loud beeps (85 dB(A) at 3 meters).
  • Penggera Visual: A flashing red "CO" LED indicator.

5.4 Low Battery Indication and Sleep Easy™ Function

When the batteries are low, the device will indicate this with:

  • Petunjuk Visual: A flashing orange "!" LED symbol.
  • Petunjuk Boleh Didengar: An audible beep.

To temporarily silence the low battery alert for 8 hours, press the test button. This activates the Sleep Easy™ mode, allowing you to silence the low battery beep, while the orange LED continues to flash as a reminder to replace the batteries.

FireAngel FA6813 Carbon Monoxide Detector with batteries and box

Figure 5: The FA6813 detector with its components, illustrating the advanced electrochemical sensor, Sleep Easy™ function, LED indicators, and sound ampciri lifikasi.

6. Penyelenggaraan

6.1 Penggantian Bateri

When the low battery indicator (flashing orange LED and beep) activates, it is time to replace the batteries. Follow the battery installation steps outlined in Section 4.1. Always use new, high-quality AA alkaline batteries.

6.2 Pengujian Berkala

It is crucial to test your CO detector regularly, at least once a week or monthly, by pressing the test button. This ensures the alarm and its internal circuitry are functioning correctly.

6.3 Pembersihan

Clean the exterior of the detector periodically with a soft, damp cloth. Do not use cleaning solvents or polishes, as these can damage the unit or interfere with the sensor's operation. Do not paint the unit.

7. Penyelesaian masalah

MasalahKemungkinan PuncaPenyelesaian
Alarm sounds (4 beeps, red LED)Carbon monoxide detected.Follow the "In Case of a CO Alarm" procedure (Section 2). Do not ignore the alarm.
Orange LED flashes and unit beeps periodicallyAmaran bateri lemah.Replace both AA batteries immediately. Use the Sleep Easy™ function if needed to silence for 8 hours.
Test button does not activate alarmBatteries are dead or incorrectly installed; unit malfunction.Check battery installation and replace if necessary. If problem persists, the unit may need replacement.
Unit tidak dihidupkanBateri mati atau tidak dipasang dengan betul.Ensure batteries are new and inserted with correct polarity.

8. Spesifikasi

CiriPerincian
Nombor ModelFA6813-EUX10
PengeluarMalaikat Api
Dimensi (L x W x H)12.3 x 7.3 x 3.55 cm (approx. 5 x 12.3 x 8 cm from other spec)
Berat badan141 Gram
warnaputih
Sumber Kuasa2 x Bateri Alkali AA (termasuk)
Jenis SensorElektrokimia
Keras Penggera85 dB(A) pada 3 meter
Kelembapan OperasiKelembapan relatif 25 hingga 95%
Kehidupan Sensor10 tahun
FireAngel FA6813 Carbon Monoxide Detector with dimensions

Figure 6: The compact design of the FA6813, illustrating its dimensions and weight.

9. Waranti dan Sokongan

FireAngel is committed to providing high-quality safety products. For any questions, technical assistance, or warranty claims, please contact your supplier or refer to the FireAngel official webtapak untuk maklumat sokongan.

Regular maintenance and adherence to the instructions in this manual will help ensure the longevity and proper functioning of your CO detector.

FireAngel brand image with a person looking up

Figure 7: FireAngel's commitment to protecting and improving lives through advanced and innovative technology.

Dokumen Berkaitan - FA6813-EUX10

Praview Manual Pengguna Penggera Karbon Monoksida FireAngel FA6813
Comprehensive user manual for the FireAngel FA6813 Carbon Monoxide Alarm, covering installation, operation, maintenance, troubleshooting, and safety information.
Praview FireAngel FA6812/FA6813 Carbon Monoxide Alarm User Manual
User manual for the FireAngel FA6812 and FA6813 Carbon Monoxide (CO) alarms, providing installation, operation, safety, and maintenance instructions.
Praview FireAngel FA3313, FA3322, FA3328, FA3820 Carbon Monoxide Alarm User Manual
Comprehensive user manual for FireAngel carbon monoxide alarms (models FA3313, FA3322, FA3328, FA3820), covering installation, positioning, operation, maintenance, technical specifications, warranty, and disposal.
Praview Manual Pengguna Gabungan Asap dan Karbon Monoksida FireAngel SCB10
User manual for the FireAngel SCB10, a combination smoke and carbon monoxide alarm, providing comprehensive instructions on installation, operation, maintenance, and safety for residential use.
Praview FireAngel CO-9X 7 Year Life Carbon Monoxide Detector User Manual
Comprehensive user manual for the FireAngel CO-9X 7 Year Life Carbon Monoxide Poisonous Gas Alarm. Learn about installation, operation, maintenance, safety, and troubleshooting.
Praview FireAngel CO Alarms FA3313, FA3322, FA3328, FA3820 User Manual & Safety Guide
Comprehensive user manual for FireAngel Carbon Monoxide (CO) alarms, models FA3313, FA3322, FA3328, and FA3820. Covers installation, positioning, alarm awareness, maintenance, system status indicators, technical specifications, warranty, and disposal.