Vertiv GXT5LI-1500LVRT2UXLN

Vertiv Liebert GXT5 Lithium-Ion N Online UPS

Instruction Manual for Model GXT5LI-1500LVRT2UXLN

1. Pengenalan dan Lebihview

The Vertiv Liebert GXT5 Lithium-Ion N Online UPS (Uninterruptible Power Supply) provides reliable, high-quality AC power to IT equipment. This unit is designed to protect critical loads from power disturbances and outages, ensuring continuous operation. Featuring Lithium-Ion battery technology, it offers extended battery life and reduced maintenance compared to traditional UPS systems. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your UPS.

Depan view of the Vertiv Liebert GXT5 UPS in rackmount configuration

Rajah 1: Depan view of the Vertiv Liebert GXT5 UPS, showing the display and ventilation.

2. Maklumat Keselamatan

Sila baca dan fahami semua arahan keselamatan sebelum memasang, mengendalikan atau menyelenggara UPS. Kegagalan mematuhi arahan ini boleh mengakibatkan renjatan elektrik, kebakaran atau kecederaan serius.

3. Kandungan Pakej

Verify that all items are present in the packaging. If any items are missing or damaged, contact your supplier.

4. Persediaan

4.1 Pemasangan Fizikal

The GXT5 UPS can be installed in either a rackmount or tower configuration.

Tower Configuration:

Attach the provided tower stands to the bottom of the UPS unit for stable vertical placement. Ensure adequate clearance for ventilation.

Vertiv Liebert GXT5 UPS in tower configuration with stands

Figure 2: UPS unit configured for tower installation with stands.

Rackmount Configuration:

Install the rackmount rails into your standard 19-inch equipment rack. Slide the UPS unit onto the installed rails and secure it with the provided screws.

4.2 Menyambungkan Kuasa dan Peralatan

  1. Sambungkan Kuasa Input: Pasangkan kord kuasa input UPS ke soket elektrik yang dibumikan dengan betul.
  2. Sambungkan Peralatan: Plug your critical equipment (servers, network devices, etc.) into the output receptacles on the rear panel of the UPS. Note that some outlets may be individually controllable.
  3. Pelabuhan Komunikasi: For monitoring and management, connect the USB or serial cable to your computer or network device.
  4. Optional RDU101 Card: If using the optional RDU101 network management card, insert it into the Intellislot and connect an Ethernet cable for remote monitoring.
Detailed rear panel diagram of the Vertiv Liebert GXT5 UPS showing input, output, and communication ports

Figure 3: Rear panel connections, including input power, output receptacles, and communication ports.

Diagram of the RDU101 network management card showing RJ-45 Ethernet port, status LED, reset button, Liebert sensor-network port, and USB port

Figure 4: RDU101 network management card with labeled ports.

4.3 Kuasa Awal Hidup

After all connections are secure, press the power button on the front panel to turn on the UPS. The display will illuminate, and the UPS will perform a self-test. Allow the batteries to charge for at least 24 hours before relying on them for extended backup time.

5. Mengendalikan UPS

5.1 Paparan dan Kawalan Panel Hadapan

LCD panel hadapan menyediakan maklumat status masa nyata, termasuk volum input/outputtage, load level, battery status, and alarm conditions. Use the navigation buttons to access menus and configure settings.

5.2 Mod Pengendalian

5.3 Prosedur Penutupan

To safely shut down the UPS, first power off all connected equipment. Then, press and hold the power button on the UPS front panel until the unit powers off. Disconnect the input power cord only after the UPS is completely off.

6. Penyelenggaraan

6.1 Penjagaan Bateri

The Lithium-Ion batteries in your GXT5 UPS are designed for a long service life. Regular maintenance is generally not required. However, ensure the UPS operates within recommended temperature ranges to maximize battery lifespan. Avoid frequent deep discharges if possible.

6.2 Pembersihan

Keep the UPS free from dust and debris. Use a soft, dry cloth to clean the exterior. Do not use liquid cleaners or solvents. Ensure ventilation openings are clear and unobstructed.

6.3 Kemas Kini Perisian Tegar

Periodically check the Vertiv website for available firmware updates for your UPS model. Firmware updates can provide performance enhancements, bug fixes, and new features. Follow the instructions provided with the update package carefully.

7. Penyelesaian masalah

This section provides solutions to common issues you may encounter with your UPS. For more complex problems, contact Vertiv technical support.

Masalah Kemungkinan Punca Penyelesaian
UPS tidak dihidupkan No input power; Battery deeply discharged; Power button not pressed correctly. Check input power cord connection and wall outlet. Allow UPS to charge for several hours. Press and hold power button for 2-3 seconds.
UPS berbunyi bip secara berterusan On battery power; Overload condition; Battery fault. Check input power. Reduce connected load. Check battery status on display.
Peralatan yang disambungkan kehilangan kuasa UPS battery depleted; UPS shut down due to overload; UPS fault. Check UPS display for error messages. Ensure load is within UPS capacity.

8. Spesifikasi

Ciri Spesifikasi
Nombor Model GXT5LI-1500LVRT2UXLN
Kapasiti (VA/Watts) 1500VA / 1350W
Input Voltage 120 Volt
Jenis Bateri Litium Ion
Dimensi Produk (L x W x H) 24 x 22.5 x 9.5 inci
Berat Barang 55.4 paun
warna Hitam

9. Waranti dan Sokongan

Your Vertiv Liebert GXT5 UPS is covered by a manufacturer's warranty. Please refer to the warranty card included with your product or visit the official Vertiv webtapak untuk terma dan syarat jaminan terperinci.

For technical assistance, troubleshooting, or to inquire about service, please contact Vertiv customer support. You can also explore additional resources and product information through the Vertiv Virtual Showroom:

Visit the Vertiv Virtual Showroom

QR code to scan and visit the Vertiv Virtual Showroom

Figure 5: Scan this QR code to access the Vertiv Virtual Showroom for more product information and support.