POTTER PAD 300-PD

Manual Pengguna Pengesan Foto POTTER PAD 300-PD

Model: PAD 300-PD

1. Pengenalan

This manual provides comprehensive instructions for the installation, operation, and maintenance of the POTTER PAD 300-PD Photo Detector. The PAD 300-PD is a battery-powered photoelectric smoke alarm designed to detect smoke particles and alert occupants with an audible alarm. It serves as an alternative model to the PAD200-PD.

The photoelectric sensing technology is effective at detecting slow, smoldering fires, which typically produce large smoke particles. For optimal safety, it is crucial to install and maintain this device according to the guidelines provided herein.

2. Maklumat Keselamatan

Please read and understand all safety instructions before installing or operating the POTTER PAD 300-PD Photo Detector. Failure to follow these instructions may result in improper operation of the device, leading to property damage, injury, or death.

3. Persediaan dan Pemasangan

Proper placement and installation are critical for the effective operation of your photo detector.

3.1 Penempatan Disyorkan

3.2 Locations to Avoid

3.3 Arahan Pemasangan

  1. Select a suitable mounting location on a ceiling or wall, away from corners.
  2. Twist the mounting bracket counter-clockwise to detach it from the detector unit.
  3. Position the mounting bracket on the ceiling or wall and mark the locations for the two mounting holes.
  4. Drill pilot holes if necessary and secure the mounting bracket using the provided screws.
  5. Install the battery as described in Section 3.4.
  6. Sejajarkan unit pengesan dengan pendakap pelekap dan putarkan mengikut arah jam sehingga ia terkunci dengan kukuh pada tempatnya.

3.4 Pemasangan Bateri

The POTTER PAD 300-PD is powered by a 9V battery. Ensure the battery is fresh and correctly oriented.

  1. Open the battery compartment on the back of the detector unit.
  2. Connect a new 9V battery to the battery clip, ensuring correct polarity (+ to + and - to -).
  3. Letakkan bateri ke dalam petak dan tutup penutupnya dengan ketat.
  4. Perform an initial test as described in Section 4.2.
POTTER PAD 300-PD Photo Detector

Rajah 1: Depan view of the POTTER PAD 300-PD Photo Detector. This image shows the circular, white smoke detector with concentric rings and a small black indicator light on its face.

4. Arahan Operasi

Understanding the operational indicators and testing procedures is essential for ensuring your detector is functioning correctly.

4.1 Operasi Biasa

Once installed with a fresh battery, the detector will enter normal operating mode. A small LED indicator on the front of the unit will flash approximately once every 30-40 seconds to indicate that the detector is powered and functioning correctly.

4.2 Menguji Pengesan

Test the smoke detector weekly to ensure it is working properly. To test:

  1. Press and hold the test button located on the front of the detector.
  2. Penggera akan membunyikan hon yang kuat dan berdenyut.
  3. Lepaskan butang. Penggera harus berhenti.
  4. Jika penggera tidak berbunyi, rujuk bahagian Penyelesaian Masalah.

Nota: The test button simulates the presence of smoke. It is important to test the detector regularly.

4.3 Keadaan Penggera

When smoke is detected, the detector will emit a loud, continuous audible alarm. The LED indicator will also flash rapidly. If an alarm sounds:

5. Penyelenggaraan

Regular maintenance ensures the longevity and reliability of your POTTER PAD 300-PD Photo Detector.

5.1 Membersihkan Pengesan Anda

Dust and debris can accumulate in the sensing chamber, potentially causing false alarms or preventing the detector from functioning correctly. Clean your detector at least once a month.

  1. Kosongkan bahagian luar pengesan perlahan-lahan menggunakan lampiran berus lembut.
  2. Do not use cleaning sprays or solvents on the detector.
  3. Do not remove the cover of the detector for cleaning.

5.2 Penggantian Bateri

The detector will chirp approximately once every 30-40 seconds when the battery is low. Replace the battery immediately when this occurs.

  1. Putar pengesan lawan arah jam untuk menanggalkannya dari pendakap pelekap.
  2. Buka petak bateri.
  3. Disconnect the old 9V battery and dispose of it properly.
  4. Connect a new 9V battery, ensuring correct polarity.
  5. Close the battery compartment and reattach the detector to the mounting bracket by twisting clockwise until it locks.
  6. Test the detector after battery replacement (refer to Section 4.2).

6. Penyelesaian masalah

If your POTTER PAD 300-PD Photo Detector is not functioning as expected, consult the following table for common issues and solutions.

MasalahKemungkinan PuncaPenyelesaian
Detector does not sound during test.Dead or weak battery; incorrect battery installation; faulty unit.Replace battery with a new 9V battery, ensuring correct polarity. If problem persists, replace the unit.
Detector chirps once every 30-40 seconds.Amaran bateri lemah.Replace the 9V battery immediately.
Penggera palsu.Dust or debris in sensing chamber; high humidity; cooking fumes; steam.Clean the detector (refer to Section 5.1). Relocate the detector if it's too close to kitchens or bathrooms. Ventilate the area.
LED indicator not flashing.Tiada kuasa; unit rosak.Ensure battery is correctly installed and fresh. If problem persists, replace the unit.

7. Spesifikasi

8. Waranti dan Sokongan

For warranty information or technical support regarding your POTTER PAD 300-PD Photo Detector, please contact POTTER customer service. Details for contacting support are typically found on the product packaging or the manufacturer's official webtapak.

Please have your model number (PAD 300-PD) and purchase information ready when contacting support.