1. Pengenalan
This manual provides essential information for the safe and efficient use of your IMMERGAS Victrix Pro 55 ERP condensing boiler, model 3.025612. Please read these instructions carefully before installation, operation, or maintenance. This boiler is designed for heating purposes only.
2. Maklumat Keselamatan Penting
Amaran: Pemasangan, pelarasan, pengubahan, servis atau penyelenggaraan yang tidak betul boleh menyebabkan kerosakan harta benda, kecederaan atau kematian. Baca arahan pemasangan, pengendalian dan penyelenggaraan dengan teliti sebelum memasang atau menservis peralatan ini.
- Pemasangan dan servis mesti dilakukan oleh pemasang yang berkelayakan, agensi perkhidmatan atau pembekal gas.
- Jangan simpan atau gunakan petrol atau wap dan cecair mudah terbakar lain di sekitar ini atau mana-mana perkakas lain.
- Ensure adequate ventilation as specified in local regulations.
- Keep the area around the appliance clear and free from combustible materials.
- In case of a gas leak, do not operate any electrical switches, extinguish any open flames, and immediately contact your gas supplier.
3. Persediaan dan Pemasangan
The IMMERGAS Victrix Pro 55 ERP boiler is designed for both indoor and outdoor installation. Due to the complexity and safety requirements, installation must be carried out by a certified professional in accordance with all local and national codes and regulations.
3.1 Membongkar dan Pemeriksaan
Carefully remove the boiler from its packaging. Inspect the unit for any signs of damage that may have occurred during transit. Report any damage to your supplier immediately.
3.2 Pertimbangan Penempatan
Pertimbangkan perkara berikut apabila memilih lokasi pemasangan:
- Dimensi: The boiler measures approximately 49.9 x 44 x 85.1 cm. Ensure sufficient space for installation and future servicing.
- Berat: The unit weighs approximately 30 kg. Ensure the mounting surface or floor can support this weight.
- Pengudaraan: Adhere to all ventilation requirements for gas appliances.
- Kebolehcapaian: Ensure easy access for maintenance and service.

Rajah 1: Depan view of the IMMERGAS Victrix Pro 55 ERP condensing boiler. This image shows the compact design suitable for various installations.
4. Arahan Operasi
Once installed and commissioned by a qualified technician, your IMMERGAS Victrix Pro 55 ERP boiler is ready for operation. This boiler is designed exclusively for central heating applications.
4.1 Permulaan Permulaan
The initial start-up procedure should be performed by the installing technician to ensure all connections are secure and the system is properly purged of air.
4.2 Operasi Asas
- Hidupkan/Mati Kuasa: Use the main power switch on the boiler or external control panel to turn the unit on or off.
- Pelarasan Suhu: Adjust the desired heating temperature using the boiler's control panel or an external thermostat. Refer to the specific controls manual for detailed instructions on setting heating curves and schedules.
- Tekanan Sistem: Regularly check the system pressure gauge. It should typically be within the manufacturer's recommended range (e.g., 1.0 to 1.5 bar when cold). Consult your installer if the pressure is consistently too low or too high.
5. Penyelenggaraan
Regular maintenance is crucial for the longevity, efficiency, and safe operation of your IMMERGAS Victrix Pro 55 ERP boiler. Annual servicing by a qualified technician is highly recommended.
5.1 Penyelenggaraan Pengguna (Bulanan/Suku Tahunan)
- Pemeriksaan Visual: Check for any visible leaks, corrosion, or unusual noises.
- Pemeriksaan Tekanan: Monitor the system pressure and top up if necessary (refer to your installer's guidance).
- Pembersihan: Ensure the area around the boiler remains clear of obstructions.
5.2 Penyelenggaraan Profesional (Setahun)
A qualified technician should perform the following tasks annually:
- Cleaning of the heat exchanger and burner.
- Memeriksa dan melaraskan tekanan gas.
- Inspection of all safety devices.
- Testing of flue gas emissions.
- Checking and cleaning of condensate trap.
- General system check and optimization.
6. Penyelesaian masalah
This section provides basic troubleshooting steps for common issues. For complex problems or if you are unsure, always contact a qualified service technician.
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| No heating/Boiler not firing | No power, low system pressure, gas supply off, thermostat setting too low. | Check power supply, check system pressure and top up if needed, ensure gas valve is open, check thermostat settings. |
| Dandang mengeluarkan bunyi yang luar biasa | Air in the system, pump issues, limescale buildup. | Bleed radiators, contact a qualified technician for inspection. |
| Kod ralat dipaparkan | Kerosakan khusus yang dikesan oleh diagnostik dalaman dandang. | Note the error code and consult the detailed technical manual or contact a service technician. |
7. Spesifikasi Teknikal
Below are the key technical specifications for the IMMERGAS Victrix Pro 55 ERP boiler, model 3.025612:
| Ciri | Perincian |
|---|---|
| Pengeluar | IMMERGAS |
| Nombor Bahagian | 3.025612 |
| Dimensi Produk (L x W x H) | 49.9 x 44 x 85.1 cm |
| Berat Barang | 30 kg |
| Nombor Model | 3.025612 |
| Item dalam Pakej | 1 (boiler) |
| Bateri Diperlukan | Tidak |
| ASIN | B0BFB651L7 |
| Tarikh Tersedia Pertama | 14 September 2022 |
8. Waranti dan Sokongan
8.1 Maklumat Waranti
Specific warranty terms and conditions for the IMMERGAS Victrix Pro 55 ERP boiler are provided by the manufacturer or your point of purchase. Please retain your proof of purchase and consult the warranty documentation included with your product or contact your seller for details regarding warranty coverage and duration.
8.2 Sokongan Pelanggan
For technical assistance, spare parts, or service requests, please contact your authorized IMMERGAS dealer or the service provider from whom you purchased the boiler. Ensure you have the model number (3.025612) and serial number of your unit available when contacting support.