This manual provides detailed instructions for the installation, operation, and maintenance of your Chamberlain CHLA250EVC Electric Swing Gate Opener. Please read this manual thoroughly before beginning installation or operation to ensure safe and efficient use of the product. This durable and robust 800 N swing gate motorization system is designed for reliable performance.
2. Maklumat Keselamatan
Your safety and the safety of others are extremely important. This manual outlines important safety messages. Always read and follow all safety instructions.
- Pastikan semua sambungan elektrik dilakukan oleh juruelektrik yang berkelayakan dan mematuhi peraturan tempatan.
- Keep hands and feet clear of the gate and gate opener mechanism during operation.
- Jangan benarkan kanak-kanak bermain atau mengendalikan alat kawalan pembuka pintu pagar.
- Regularly inspect the gate and opener for signs of wear, damage, or improper balance.
- In case of power failure, use the manual release mechanism to operate the gate.
- Install safety sensors (photocells) to prevent the gate from closing on obstructions.
3. Kandungan Pakej
Carefully unpack all components and verify that all items listed below are present. If any parts are missing or damaged, contact your retailer immediately.

Image: All components of the Chamberlain CHLA250EVC gate opener system, including two operators, control box, remote controls, safety sensors, and mounting hardware.
- 2 x Chamberlain CHLA250EVC Gate Operators
- 1 x Control Unit / Control Box
- 2 x Alat Kawalan Jauh
- 2 x Safety Photocell Sensors
- Pemasangan Pendakap dan Perkakasan
- Kunci Pelepas Manual
- Manual Arahan
4. Persediaan dan Pemasangan
Installation should be performed by individuals with appropriate technical knowledge. Ensure the gate operates smoothly manually before installing the opener.
4.1 Penyediaan Tapak
- Ensure the gate posts are sturdy and capable of supporting the opener's weight and forces.
- Verify that the gate swings freely without obstruction and is properly balanced.
- Plan the routing for electrical cables, ensuring they are protected and comply with local electrical codes.
4.2 Mounting the Gate Operators

Image: A single Chamberlain gate operator mounted on a swing gate, illustrating typical installation.
- Attach the mounting brackets securely to the gate post and the gate frame according to the provided template.
- Mount the gate operators to the brackets, ensuring they are level and aligned for smooth gate movement.
- Adjust the operator's length to achieve the desired open and closed positions.
4.3 Sambungan Elektrik
- Connect the gate operators to the control unit.
- Wire the safety photocell sensors to the control unit. Position sensors to detect obstructions in the gate's path.
- Connect the control unit to a suitable 240V power supply, ensuring proper grounding. The system operates on 24 Volts internally.
4.4 Programming Remote Controls

Image: A Chamberlain remote control with three buttons, used for operating the gate opener.
- Refer to the control unit's specific instructions for programming the remote controls.
- Typically, this involves pressing a 'learn' button on the control unit and then a button on the remote.
- Test each remote control to ensure it operates the gate correctly.
5. Arahan Operasi
5.1 Operasi Standard
- Press the programmed button on your remote control to open or close the gate.
- Pressing the button again during operation will typically stop the gate. A third press will reverse its direction.
- Ensure the gate path is clear before and during operation.
5.2 Pembatalan Manual
In case of power failure or malfunction, the gate can be operated manually:
- Locate the manual release mechanism on each gate operator.
- Insert the provided key and turn it to disengage the motor.
- The gate can now be opened or closed by hand.
- To re-engage, reverse the manual release procedure.
5.3 MyQ Smart Control (If applicable)
This system may be compatible with Chamberlain's MyQ technology, allowing you to monitor and control your gate from your smartphone. Refer to the MyQ app instructions for setup and usage.
6. Penyelenggaraan
Regular maintenance ensures the longevity and safe operation of your gate opener.
- Bulanan: Check the gate's balance and ensure it moves freely. Inspect all mounting hardware for tightness.
- Suku tahunan: Clean the gate operators and photocell lenses. Test the safety sensors by placing an object in the gate's path during closing. The gate should reverse.
- Setiap tahun: Have a qualified technician inspect the entire system, including electrical connections and motor performance.
7. Penyelesaian masalah
If you encounter issues, consult this section before contacting support.
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Pintu pagar tidak boleh dibuka/ditutup | Tiada kuasa; Bateri alat kawalan jauh mati; Sensor keselamatan tersumbat; Pembebasan manual diaktifkan. | Check power supply; Replace remote battery; Clear sensor path; Disengage manual release. |
| Pintu berundur secara tidak dijangka | Safety sensors obstructed; Obstruction in gate path; Force settings too sensitive. | Clear sensor path/gate path; Adjust force settings (refer to control unit manual). |
| Alat kawalan jauh tidak berfungsi | Battery dead; Remote out of range; Remote not programmed. | Replace battery; Move closer to gate; Reprogram remote (see Section 4.4). |
8. Spesifikasi
| Ciri | Perincian |
|---|---|
| Nama Model | CHLA250EVC |
| Jenama | Chamberlain |
| Dimensi Produk (L x W x H) | 7 x 8 x 17 cm (per operator) |
| Berat badan | 4 kilogram (jumlah pakej) |
| Kapasiti | Up to 200 Kilograms (per gate leaf) |
| kuasa | 800 N (Newton) force |
| Voltage | 240 Volts (input), 24 Volts (system) |
| bahan | plastik |
9. Waranti dan Sokongan