Locinox VERTICLOSE-2-9005

Manual Arahan Penutup Pagar Hidraulik Locinox Verticlose 2

1. Pengenalan

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Locinox Verticlose 2 Hydraulic Gate Closer. Designed for both 90° and 180° hinge applications, this gate closer features integrated pre-tension, adjustable closing speed, and a final snap mechanism. The Quick-Fix mounting system facilitates efficient installation, and its anodized aluminum construction ensures durability.

2. Ciri-ciri Produk

  • Micro adjustment of speed and final snap for precise gate closing.
  • Includes railset for versatile installation in 90° and 180° hinge situations.
  • Weatherproof, scratch-resistant, and corrosion-free anodized aluminum housing ensures longevity.
  • Robust and stylish design with high-quality internal components.
  • Integrated pre-tension for smooth and efficient installation.
  • Consistent closing speed maintained by patented hydraulic dampteknologi dalam.
  • Securely fixed using the patented Quick-Fix system.
  • ADA compliant (< 5 lbs; max 25 Nm) for gate widths of 4ft or more.

3. Maklumat Keselamatan

Please read and understand all instructions before installation and operation. Failure to follow these instructions may result in injury or product damage.

  • Sentiasa pakai peralatan pelindung diri (PPE) yang sesuai semasa pemasangan, termasuk cermin mata keselamatan dan sarung tangan.
  • Ensure the gate is securely supported during installation to prevent accidental movement.
  • Do not attempt to disassemble the hydraulic unit. It contains pressurized components.
  • Keep hands and clothing clear of moving parts during operation and adjustment.
  • This product is designed for gate closing applications only. Do not use for other purposes.

4. Persediaan dan Pemasangan

The Verticlose 2 is designed for efficient installation using the Quick-Fix mounting system. The included railset supports both 90° and 180° hinge configurations.

4.1 Kandungan Pakej

  • Verticlose 2 Hydraulic Gate Closer unit
  • Railset for 90° and 180° situations
  • Quick-Fix mounting hardware
  • Manual Arahan

4.2 Langkah Pemasangan

  1. Prepare the Gate and Post: Ensure the gate and post are structurally sound and free from obstructions.
  2. Mount the Quick-Fix System: Attach the Quick-Fix mounting plates to the gate and post according to the desired hinge situation (90° or 180°). Refer to the diagrams for precise positioning.
  3. Install the Closer Unit: Securely attach the Verticlose 2 hydraulic unit to the Quick-Fix mounting plates. The integrated pre-tension feature will assist in this step.
  4. Connect the Railset: Attach the appropriate railset components between the closer unit and the gate/post, ensuring proper alignment.
  5. Pelarasan Awal: Perform an initial check of the gate's movement and make preliminary adjustments to the closing speed and final snap as described in Section 5.
Locinox Verticlose 2 Hydraulic Gate Closer with mounting arms

Rajah 1: The Locinox Verticlose 2 Hydraulic Gate Closer shown with its main cylindrical body and the two railset arms for mounting.

5. Operasi dan Pelarasan

The Verticlose 2 allows for precise adjustment of the closing speed and final snap to suit specific gate requirements.

5.1 Adjusting Closing Speed

Locate the speed adjustment screw on the closer unit. Turning the screw clockwise will decrease the closing speed, making the gate close slower. Turning it counter-clockwise will increase the closing speed, making the gate close faster. Make small adjustments and test the gate's movement after each adjustment.

5.2 Adjusting Final Snap

The final snap adjustment controls the force with which the gate latches shut in the last few degrees of closing. Locate the final snap adjustment screw. Turning it clockwise will increase the snap force, while turning it counter-clockwise will decrease it. Adjust as needed to ensure the gate securely latches without excessive force.

6. Penyelenggaraan

Regular maintenance ensures optimal performance and extends the lifespan of your Verticlose 2 gate closer.

  • Pembersihan: Periodically clean the exterior of the closer unit and railset with a soft, damp kain untuk menghilangkan kotoran dan serpihan. Elakkan pembersih yang kasar.
  • Pemeriksaan: Annually inspect all mounting hardware for tightness. Check the railset for any signs of wear or damage.
  • Pelinciran: The hydraulic unit is sealed and does not require internal lubrication. Ensure any moving pivot points on the railset are free of obstruction.
  • Semakan Prestasi: Periodically check the closing speed and final snap. Readjust if necessary due to environmental changes or wear.

7. Penyelesaian masalah

This section addresses common issues you might encounter with your Verticlose 2 gate closer.

MasalahKemungkinan PuncaPenyelesaian
Gate closes too fast/slowSpeed adjustment incorrectAdjust the closing speed screw (refer to Section 5.1).
Gate does not latch securelyFinal snap adjustment incorrectAdjust the final snap screw (refer to Section 5.2).
Gate binds or sticksObstruction in gate path or hinge issuesCheck for physical obstructions. Inspect gate hinges for proper function and lubrication.
Closer unit leaking fluidInternal seal failureContact Locinox customer support for assistance. Do not attempt to repair.

8. Spesifikasi Teknikal

Nombor ModelVERTICLOSE-2-9005
JenamaLocinox
bahanaluminium
warnaHitam
Kemasan LuaranHitam
Berat Barang11.53 paun
Dimensi Produk2.5 x 3 x 15.5 inci
Jenis PemasanganSkru Masuk
Penggunaan yang DisyorkanCommercial buildings, high-traffic areas
Spesifikasi MetADA

9. Waranti dan Sokongan

For warranty information, technical support, or replacement parts, please contact Locinox customer service directly. Refer to the official Locinox webtapak atau dokumentasi pembelian anda untuk butiran hubungan.