Fitnet AL-300L

Fitnet AL-300L 79 Gallon Aquarium Chiller Instruction Manual

Model: AL-300L

1. Pengenalan

This manual provides detailed instructions for the safe and efficient operation of your Fitnet AL-300L Aquarium Chiller. This unit is designed to maintain optimal water temperatures for various aquatic environments, including freshwater and saltwater aquariums, as well as hydroponic systems. Please read this manual thoroughly before installation and use to ensure proper function and longevity of the product.

Fitnet AL-300L Aquarium Chiller main unit

Figure 1: Fitnet AL-300L Aquarium Chiller. This image shows the main chiller unit with its digital display and water inlet/outlet nozzles.

Ciri-ciri produk:

Image showing the chiller being used for both hydroponic systems and fish tanks

Figure 2: Versatile applications. This image illustrates the chiller's suitability for both hydroponic systems (top) and traditional fish tanks (bottom).

2. Maklumat Keselamatan

Sila patuhi langkah berjaga-jaga keselamatan berikut untuk mengelakkan kecederaan atau kerosakan pada produk.

Diagram showing recommended 6 inch clearance around chiller for heat dissipation

Figure 3: Recommended clearance for heat dissipation. This diagram illustrates the importance of maintaining at least 6 inches (15 cm) of space between the chiller and any walls or obstructions to ensure proper airflow and cooling efficiency.

3. Kandungan Pakej

Sahkan bahawa semua item terdapat dalam pakej sebelum meneruskan pemasangan.

Image showing all components included with the Fitnet Aquarium Chiller

Figure 4: Included components. This image displays the main chiller unit alongside the water pump, hoses, connectors, and clamps that come with the product.

Close-up of the submersible water pump included with the chiller

Figure 5: Submersible water pump. This image shows the water pump, designed for submersion in fresh or saltwater, which circulates water through the chiller.

4. Arahan Persediaan

Follow these steps for proper installation of your aquarium chiller.

  1. Positioning the Chiller: Place the chiller on a flat, stable surface near your aquarium or hydroponic system. Ensure there is at least 6 inches (15 cm) of clear space around all sides for optimal airflow and heat dissipation.
  2. Prepare Connectors: Gather the provided connectors, including the white sealing washers.
  3. Install Inlet/Outlet Nozzles:
    • Insert a white sealing washer onto each inlet/outlet nozzle.
    • Place the pipe joint into the black nut cap.
    • Tighten the black nuts onto the chiller's inlet and outlet ports.
  4. Sambungkan Pam Air: Attach one end of the water pipe to the outlet of the submersible water pump. Secure it with a clamp jika perlu.
  5. Connect Chiller to System:
    • Connect the other end of the water pipe from the pump to the chiller's inlet port.
    • Connect a second water pipe from the chiller's outlet port back to your aquarium or hydroponic system.
    • Pastikan semua sambungan selamat dan kedap air untuk mengelakkan kebocoran.
  6. Pam Tenggelam: Place the submersible water pump into your aquarium or hydroponic reservoir. Ensure it is fully submerged and positioned to draw water effectively.
  7. Sambungan Kuasa: Plug the chiller's power cord into a GFCI-protected electrical outlet. Plug in the water pump's power cord.
Step-by-step diagram for connecting the chiller hoses and pump

Figure 6: Chiller installation steps. This diagram illustrates the process of preparing accessories, installing sealing washers, attaching pipe joints, and tightening the black nuts for secure hose connections.

Fitnet Aquarium Chiller connected to a fish tank, showing dimensions

Figure 7: Chiller setup with an aquarium. This image shows the chiller unit connected to a small fish tank, illustrating the hose routing and the overall footprint of the chiller (dimensions: 12.6" H x 11.4" W x 11.4" D).

5. Arahan Operasi

The chiller features a digital control panel for temperature setting and calibration.

5.1. Hidupkan/Mati Kuasa

Locate the power switch on the back of the unit. Flip the switch to the 'ON' position to power on the chiller. The digital display will illuminate.

Close-up of the power switch on the back of the chiller unit

Figure 8: Power switch. This image shows the main power switch located on the rear panel of the chiller unit.

5.2. Temperature Setting (Assumed Target Temperature Range: 75-79°F)

The chiller will begin cooling after a 2-3 minute power-on delay. To adjust the target temperature:

  1. Set Shutdown Temperature: Tekan ke Tetapkan kunci. Menggunakan (atas) atau (down) arrow keys to adjust the desired shutdown temperature (e.g., 77°F). Press the Rst kunci untuk disimpan.
  2. Set Starting Temperature (F1 Code): Tekan lama Tetapkan kunci sehingga F1 code appears. Then, press the Tetapkan key again. Use the or arrow keys to adjust the temperature difference (e.g., to 4°F for a working range of 4°F).
Diagram showing temperature setting and calibration steps on the chiller's control panel

Figure 9: Temperature setting and F2 calibration. This image provides a visual guide to setting the shutdown temperature and adjusting the F1 code for the working temperature range, as well as the F2 calibration process.

5.3. F2 Calibration Setting

If the chiller's displayed temperature does not match an external thermometer, you can calibrate it:

  1. Tekan lama Tetapkan kunci untuk dipaparkan F1. Tekan ke kunci untuk dipaparkan F2. Tekan Tetapkan sekali lagi.
  2. Gunakan or arrow keys to adjust the offset value (e.g., to 5 if the chiller reads 77°F and the actual temperature is 72°F, meaning a -5 adjustment is needed). Press Rst untuk kembali ke paparan suhu semasa.

6. Penyelenggaraan

Regular maintenance ensures optimal performance and extends the lifespan of your chiller.

7. Penyelesaian masalah

If you encounter issues with your chiller, refer to the following common problems and solutions.

MasalahKemungkinan PuncaPenyelesaian
Chiller not cooling or insufficient cooling.
  • Insufficient airflow around the unit.
  • Water pump not operating or clogged.
  • Ambient room temperature too high.
  • Water volume too large for chiller capacity.
  • Temperature settings incorrect.
  • Ensure 6 inches (15 cm) clearance around the chiller.
  • Check pump for power and blockages; clean if necessary.
  • Reduce room temperature or consider a higher capacity chiller.
  • Reduce water volume if possible, or allow more time for cooling.
  • Verify temperature settings (Section 5.2).
Air bocor dari sambungan.
  • Sambungan hos longgar.
  • Damaged sealing washers or hoses.
  • Ketatkan semua hos clamps dan sambungan.
  • Inspect and replace any damaged washers or hoses.
Chiller making unusual noise.
  • Vibrations from compressor (normal to some extent).
  • Penghalang kipas.
  • Unit bukan aras.
  • Ensure unit is on a stable, level surface.
  • Check fan vents for obstructions and clean if necessary.
  • Some compressor noise is normal; ensure it's not excessive.
Digital display shows incorrect temperature.
  • Penentukuran diperlukan.
  • Perform F2 calibration as described in Section 5.3.

8. Spesifikasi

CiriPerincian
Nama ModelAL-300L
Kapasiti79 Gelen / 300 Liter
Dimensi (L x W x H)12.6 x 11.4 x 11.39 inci
Bahan penyejukR134a
Julat Suhu Disyorkan68°F - 79°F (20°C - 26°C)
bahanaluminium
warnaHitam
Pengeluarfitnessnet
Pump Power (Qmax)15W, 600L/H
Voltage110V/60HZ

9. Waranti dan Sokongan

Fitnet offers a Jaminan pengilang 1 tahun for this 79-gallon water chiller. This warranty covers defects in materials and workmanship under normal use.

For warranty claims, technical support, or any questions regarding your Fitnet Aquarium Chiller, please contact Fitnet customer service through your original purchase platform or the official Fitnet webtapak.

Sila simpan bukti pembelian anda untuk pengesahan waranti.

Dokumen Berkaitan - AL-300L

Praview Penyejuk Air Akuarium Poafamx 42GAL/160L AL-160G Arahan
Manual arahan untuk Penyejuk Air Akuarium Poafamx AL-160G (42GAL/160L). Ketahui tentang pemasangan, pengendalian, parameter dan penyelesaian masalah untuk mengekalkan suhu air optimum dalam akuarium dan sistem hidroponik.
Praview Baoshishan Aquarium Water Chiller Handling Instructions
This document provides handling instructions for Baoshishan Aquarium Water Chillers, covering introduction, safety precautions, parameters, installation, testing, temperature settings, cleaning, maintenance, and troubleshooting for models AL-60, AL-160, and AL-300.
Praview Manual Pengguna Pam/Penapis Air: Panduan Keselamatan dan Operasi
Manual pengguna ini menyediakan langkah berjaga-jaga keselamatan yang penting dan arahan pengendalian untuk pam air tenggelam yang digunakan dalam akuarium, kolam dan aplikasi peredaran air yang lain. Ia merangkumi garis panduan pemasangan, penggunaan dan penyelenggaraan.
Praview Adam Equipment MDW-300L Health and Fitness Scale with BMI User Manual
User manual for the Adam Equipment MDW-300L Health and Fitness Scale, detailing its features, technical specifications, setup, operation, calibration, user parameters, RS232 communications, error messages, and warranty information.
Praview Manual Pemanas Air Kospel SWPC 300L
Pemasangan, operasi dan spesifikasi teknikal untuk silinder air panas domestik Kospel SWPC 300L.
Praview Jebao AL & AK Series Aquarium Light User Manual - Setup, Features, and App Control
Comprehensive user manual for Jebao AL and AK Series aquarium lights. Covers product introduction, specifications, installation, Wi-Fi setup, app download and control, modes, and troubleshooting.