1. Produk Lebihview

The Suntree DC Molded Case Circuit Breaker is engineered to safeguard DC electrical installations from overloads and short circuits. It incorporates both thermal and magnetic tripping mechanisms for reliable protection. Upon detecting a fault, the circuit breaker automatically interrupts the electrical circuit, preventing wire damage and reducing fire risk. This device can also be manually opened under its full rated load for electrical maintenance without sustaining damage. Designed for reversible connection, the circuit breaker can be wired in either direction and supports bidirectional current flow. Clear markings on the handle indicate the contact position (ON/OFF) at a glance. Its design facilitates easy installation on both standard DIN rails and vertical surfaces.

Renogy Suntree 160 Amp 2-Pole DC Circuit Breaker

Figure 1: Renogy Suntree 160 Amp 2-Pole DC Circuit Breaker

2. Maklumat Keselamatan

  • Always disconnect power before installing or servicing the circuit breaker.
  • Installation should be performed by qualified personnel in accordance with local electrical codes and standards.
  • Ensure proper wire sizing and terminal connections to prevent overheating.
  • Jangan kendalikan pemutus litar jika ia kelihatan rosak.
  • Pakai peralatan pelindung diri (PPE) yang sesuai semasa bekerja dengan sistem elektrik.

3. Pemasangan

3.1 Kandungan Pakej

  • 160A 2P DC Molded Case Circuit Breaker
  • Skru Pemasangan
  • Insulation Barrier (2 pieces)
Dimensions and included components of the circuit breaker

Figure 2: Product Dimensions and Included Components

3.2 Pemasangan

The circuit breaker supports both DIN rail and vertical surface mounting. Ensure the mounting location is dry, well-ventilated, and protected from direct sunlight and extreme temperatures.

Diagram showing quick installation on DIN rail with insulation barriers

Figure 3: Quick Installation on DIN Rail

3.3 Sambungan Pendawaian

Connect the DC positive and negative cables to the corresponding terminals on the circuit breaker. The circuit breaker is designed for reversible connection and functions with bidirectional current. Ensure all connections are secure and tight. Install the provided insulation barriers between terminals for enhanced safety.

Wiring diagram showing positive and negative connections to the circuit breaker

Rajah 4: Rajah Sambungan

3.4 Sizing Tips for Circuit Breaker Selection

Proper sizing is crucial for effective protection.

  • For controller/inverter/DC device:
    1. Determine the maximum continuous operating current (current = watt/voltagdan).
    2. Calculate maximum current = 1.25 x maximum continuous operating current.
    3. Select a circuit breaker whose rated current is greater than and closest to the calculated maximum current.
  • For solar panel:
    1. Determine the short-circuit current.
    2. Calculate maximum current = Short-circuit current x 1.25 x 1.25.
    3. Select a circuit breaker whose rated current is greater than and closest to the calculated maximum current.
Diagram illustrating sizing tips for circuit breakers in solar systems

Figure 5: Circuit Breaker Sizing Guidelines

4. Operasi

4.1 Menghidupkan / Mematikan

To switch the circuit breaker ON, push the handle to the 'ON' position. To switch it OFF, push the handle to the 'OFF' position. The handle's position clearly indicates the contact status.

Image showing the ON and OFF positions of the circuit breaker handle

Figure 6: ON/OFF Markings

4.2 Protection Mechanisms

The circuit breaker provides protection against both overload and short-circuit conditions. In the event of an electrical fault, the breaker will automatically trip to protect the system.

Diagram illustrating overload and short-circuit protection features

Figure 7: Overload and Short-circuit Protection

5. Penyelenggaraan

After the circuit breaker has tripped due to a fault, it can be reset manually. No damage occurs to the breaker itself from tripping. Regular visual inspection for any signs of wear or damage is recommended. Ensure connections remain tight.

Diagram showing mechanical and electrical life cycles, and high electrical conductivity

Figure 8: Durability and Conductivity

6. Penyelesaian masalah

  • Breaker trips frequently: This indicates an overload or short circuit in the system. Identify and resolve the underlying electrical issue before resetting the breaker.
  • Breaker does not reset: Ensure the fault condition has been cleared. If the breaker still does not reset, it may be damaged and require replacement.
  • No power after installation: Verify all wiring connections are correct and secure. Check for proper input voltage and ensure the breaker is in the 'ON' position.

7. Spesifikasi

CiriSpesifikasi
JenamaRenogy
Penilaian Semasa160 Amps
Jenis Pemutus LitarStandard
Jenis PemasanganLekapan Permukaan
Bilangan Tiang2
UPC810009719694
PengeluarRenogy
Nombor BahagianSUNDCCB160MC2P
Berat Barang5.15 paun
Dimensi Produk7.9 x 3.5 x 5.3 inci
bahanTembaga
Komponen yang Disertakan160A 2P DC Molded Case Circuit Breaker, Mounting Screws, Insulation Barrier

8. Waranti dan Sokongan

Renogy offers a 1-year material and workmanship warranty for this product. For technical support or warranty claims, please visit the official Renogy webtapak atau hubungi perkhidmatan pelanggan mereka.

Untuk maklumat lanjut, lawati Renogy Store.

Dokumen Berkaitan - SUNDCCB160MC2P

Praview Manual Umum Kit Solar Luar Grid Renogy: Panduan Pemasangan dan Operasi
Manual ini menyediakan arahan komprehensif untuk memasang, memasang pendawaian dan menyelenggara Kit Solar Luar Grid Renogy. Ketahui tentang langkah berjaga-jaga keselamatan, sistem pemasangan, konfigurasi bateri dan sambungan sistem untuk kuasa luar grid yang andal.
Praview Manual Pengguna Kit Solar Luar Grid Renogy: Panduan Pemasangan, Pendawaian dan Pemasangan
Manual pengguna yang komprehensif untuk Kit Solar Luar Grid Renogy, meliputi pemasangan, pendawaian, sistem pelekap (Z-Bracket, Rel, Tiang), konfigurasi bateri, langkah keselamatan dan penggunaan fius ANL untuk RV, bot dan sistem kuasa luar grid.
Praview Manual Pengguna Renogy Battery Shunt 300
Manual pengguna yang komprehensif untuk Renogy Battery Shunt 300, yang menyediakan panduan pemasangan, operasi, konfigurasi dan penyelesaian masalah untuk pemantauan bateri pintar dalam sistem solar dan luar grid.
Praview Renogy ONE Core Quick Guide | Installation and Operation
A quick guide for the Renogy ONE Core (RSHGWSN-W02W-G3), covering installation, connection, and basic operation. Learn how to set up your Renogy ONE Core for optimal performance.
Praview Manual Pengguna Modul Bluetooth Renogy BT-2 dan Spesifikasi Teknikal
Panduan komprehensif untuk Modul Bluetooth Renogy BT-2, memperincikan cirinya, pengenalpastian bahagian, operasi, spesifikasi teknikal dan sambungan aplikasi untuk pengawal cas solar.
Praview Renogy ONE Core User Manual: Comprehensive Guide to Energy Monitoring and Smart Home Integration
This user manual provides detailed instructions for the Renogy ONE Core, covering installation, operation, features like RV leveling and smart home integration, troubleshooting, and technical specifications. Learn how to monitor and manage your energy systems effectively.