1. Pengenalan
This manual provides essential information for the safe and efficient operation of your LEESKY 2000W Pure Sine Wave Power Inverter. Please read these instructions thoroughly before installation and use. Retain this manual for future reference.
Kandungan Pakej:
- 1x LEESKY 2000 Watt Pure Sine Wave Power Inverter
- 2x Battery Cables (black and red)
- 1x 15ft Remote Controller
- 1x Earth Wire
- 8x Shockproof Pads
- 1x Manual Pengguna (dokumen ini)

Image 1.1: The LEESKY 2000W Pure Sine Wave Power Inverter with its included battery cables, remote controller, and GFCI outlet.
2. Maklumat Keselamatan
Observe the following safety precautions to prevent injury or damage to the inverter and connected devices:
- JANGAN exceed the inverter's rated power of 2000 Watts. Overloading can cause damage to the inverter and connected appliances.
- JANGAN leave the power inverter in the ON position while your vehicle's engine is off to prevent battery drain.
- Always disconnect the positive battery terminal before performing any wiring or maintenance on the inverter.
- Install the inverter in a cool, dry environment, away from direct sunlight, moisture, and flammable materials.
- Ensure proper ventilation around the inverter to prevent overheating. Do not block cooling fan vents.
- This inverter is designed for 12V DC input. Connecting to other voltage sources may cause severe damage.
3. Persediaan dan Pemasangan
3.1 Menyambung kepada Bateri
- Pastikan suis kuasa inverter berada dalam kedudukan OFF.
- Sambungkan kabel bateri merah ke terminal positif (+) bateri 12V anda.
- Connect the other end of the red battery cable to the positive (+) input terminal on the inverter.
- Sambungkan kabel bateri hitam ke terminal negatif (-) bateri 12V anda.
- Connect the other end of the black battery cable to the negative (-) input terminal on the inverter.
- Pastikan semua sambungan adalah ketat dan selamat.
- Connect the included earth wire to the ground terminal on the inverter and to a suitable ground point.
Nota: For optimal performance and safety, use a 12V battery with a capacity of 400 Ah or above. Always use the provided cables or cables of equivalent gauge suitable for 2000W applications.
3.2 Pemasangan Alat Kawalan Jauh
The remote controller allows for convenient monitoring and control of the inverter from a distance.
- Locate the RJ10 port on the inverter.
- Connect one end of the 15ft remote controller cable to the RJ10 port on the inverter.
- Connect the other end of the cable to the remote controller unit.
The inverter can also be turned on/off using the power switch directly on the unit if the remote controller is not connected or desired.

Imej 3.1: Selesaiview of inverter components including positive/negative terminals, GFCI outlets, USB ports, LCD display, and remote controller port.
4. Operasi
4.1 Menghidupkan Penyongsang
- After ensuring all connections are secure, switch the inverter's power button to the ON position.
- The LCD display on the inverter (or remote controller) will illuminate, showing input voltage, output wattage, and battery status.
4.2 Menyambungkan Peranti AC
The LEESKY 2000W inverter provides clean, stable pure sine wave electricity, suitable for sensitive electronics.
- Plug your AC devices into the two 110-120V AC GFCI outlets.
- For charging USB devices, use the two 2.4A USB ports.
- Pastikan jumlah wattage daripada semua peranti yang disambungkan tidak melebihi 2000W.

Image 4.1: The inverter's LCD display provides real-time information, and the GFCI outlets offer enhanced safety.
4.3 LCD Display and Remote Control
The LCD display provides critical operational data:
- Input Voltage: Memaparkan volum DC semasatage daripada bateri.
- Output Wattage: Shows the real-time power consumption of connected AC devices.
- Status Bateri: Menunjukkan tahap cas bateri.
- Kod Perlindungan: Displays error codes if a protection mechanism is triggered.
- Suhu: Menunjukkan suhu dalaman penyongsang.
The remote controller mirrors this information and allows for convenient power control. It also features a backlight switch for visibility in various lighting conditions.

Image 4.2: The remote control provides comprehensive monitoring and control, displaying input voltage, output wattage, battery status, and protection warnings.
5. Ciri Perlindungan dan Penyelesaian Masalah
The LEESKY 2000W inverter incorporates multiple protection mechanisms to ensure safe operation and prevent damage to the unit and connected devices. The LCD display will show warning symbols and protection codes when an issue occurs.
5.1 Built-in Protections:
- Perlindungan Lebihan: Activates when output power exceeds 2000W-2200W. The inverter will shut down to prevent damage.
- Perlindungan lebih suhu: Engages if the internal temperature reaches approximately 149℉ (65℃). The intelligent cooling fan runs automatically when the temperature reaches 104℉ (40℃) or load power exceeds 40% of rated power.
- Low-input Voltage Perlindungan: Triggers an alarm at 9.8V±0.5VDC and shuts down at 9.5V±0.5VDC to protect the battery from over-discharge.
- High-input Voltage Perlindungan: Mematikan inverter jika volum inputtage exceeds 16V±0.5VDC.
- Perlindungan litar pintas: Automatically protects against output short circuits.
- Perlindungan Polariti Terbalik: Prevents damage from incorrect battery terminal connections.
- Input/Output Isolated Design: Enhances safety by electrically separating input and output circuits.

Image 5.1: The inverter's multi-protection system safeguards against common electrical faults.
5.2 Troubleshooting Common Issues:
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Inverter tidak menyala. | Sambungan bateri longgar, volum bateri rendahtage, inverter switch off. | Check battery connections, charge battery, ensure inverter switch is ON. |
| Tiada output AC. | Beban lampau, litar pintas, volum input tinggi/rendahtage, GFCI tripped. | Kurangkan beban, periksa litar pintas, sahkan volum bateritage, reset GFCI. |
| Inverter shuts down. | Overload, overheating, low/high input voltage. | Reduce load, allow inverter to cool, check battery voltage. |
| Kipas berjalan secara berterusan atau kuat. | High internal temperature, heavy load. | Ensure adequate ventilation, reduce load. This is normal operation under certain conditions. |
6. Penyelenggaraan
Regular maintenance ensures the longevity and reliable performance of your LEESKY inverter.
- Pembersihan: Bersihkan bahagian luar inverter secara berkala dengan kain kering dan lembut. Jangan gunakan pembersih cecair atau pelarut.
- Pengudaraan: Ensure the cooling vents are free from dust and debris. Blocked vents can lead to overheating.
- Sambungan: Regularly check all battery and output connections to ensure they are tight and free from corrosion.
- Storan: Jika menyimpan inverter untuk tempoh yang lama, cabutnya daripada bateri dan simpan di tempat yang sejuk dan kering.
7. Spesifikasi
| Ciri | Spesifikasi |
|---|---|
| Model | LEESKY 2000W Pure Sine Wave Inverter |
| Kuasa Dinilai | 2000W (Berterusan) |
| Bentuk Gelombang Output | Gelombang Sinus Tulen |
| Herotan Harmonik Jumlah (THD) | < 3% |
| Input Voltage | 12V DC |
| Keluaran Voltage | 110-120 VAC ± 10% |
| Kekerapan Output | 60Hz |
| Semasa Idle | Lebih kurang 1.7 Amps |
| Kecekapan | Sehingga 90% |
| Outlet | 2x Soket GFCI |
| Port USB | 2x 2.4A USB |
| Panjang Kabel Alat Kawalan Jauh | 15 kaki |
| Perlindungan lebihan beban | 2000W ~ 2200W |
| Perlindungan suhu berlebihan | Around 149°F (65°C) |
| Suhu Bekerja | -22 ° F ~ 140 ° F (-30 ° C ~ 60 ° C) |
| Lebih-voltage Penutupan | 16V ± 0.5VDC |
| Di bawah voltage Penggera | 9.8V ± 0.5VDC |
| Di bawah voltage Penutupan | 9.5V ± 0.5VDC |
| Dimensi Produk | 19.85 x 9.4 x 3.8 inci |
| Berat Barang | 13.46 paun |

Image 7.1: Physical dimensions and weight of the inverter, along with battery cable specifications.
8. Waranti dan Sokongan
8.1 Maklumat Waranti
The LEESKY 2000W Pure Sine Wave Power Inverter comes with an Tempoh penyelenggaraan 18 bulan from the date of purchase. This warranty covers manufacturing defects and ensures product reliability. Please retain your proof of purchase for warranty claims.
8.2 Sokongan Pelanggan
For technical assistance, troubleshooting, or warranty inquiries, please contact LEESKY customer support through the retailer where the product was purchased or refer to the official LEESKY weblaman web untuk maklumat hubungan.