Sub-Zero SZ-7501

Manual Pengguna Pengawal/Penunjuk Suhu Sub-Zero SZ-7501 Proses Digital

Model: SZ-7501

1. Pengenalan

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Sub-Zero SZ-7501 Digital Process Controller/Temperature Indicator. This device is designed for precise temperature control across a wide range of applications, including incubators, water heaters, floor heating systems, aquariums, refrigerators, greenhouses, and various industrial cold storage facilities.

The SZ-7501 is a versatile thermostat sensor capable of operating within a 110V-220V power supply, offering both cooling and heating output functionalities.

2. Ciri-ciri Utama

  • Cooling & Heating Output: Supports both heating and cooling modes for flexible temperature management.
  • Julat Suhu Luas: Operates effectively from -50°C to +99°C.
  • Pengekalan Memori: Mengekalkan tetapan walaupun selepas kehilangan kuasa.
  • Perlindungan Pemampat: Features a time delay function to protect connected compressors.
  • Output geganti: SZ – 7510 P – 8 (3) A for reliable switching.
  • Bekalan Kuasa: Compatible with 230VAC power sources.

3. Produk Lebihview

The Sub-Zero SZ-7501 features a clear digital display and intuitive control buttons for easy operation.

Depan view of Sub-Zero SZ-7501 Digital Process Controller display showing 25 degrees Celsius

Rajah 1: Depan view of the Sub-Zero SZ-7501 Digital Process Controller. The display shows "25°C" with indicators for cooling, alarm, and a clock. Control buttons include 'Up', 'RST', 'PRG', 'Down', and 'SET'.

sebelah view of Sub-Zero SZ-7501 Digital Process Controller with sensor chord connected

Rajah 2: sebelah view of the Sub-Zero SZ-7501 controller, illustrating the compact design and the connected sensor chord. The transparent purple casing mendedahkan komponen dalaman.

4. Persediaan dan Pemasangan

Proper installation is crucial for the accurate and safe operation of the SZ-7501 controller. Ensure all power is disconnected before proceeding with installation.

4.1 Gambarajah Pendawaian (Panduan Umum)

While a specific wiring diagram is not provided in this manual, typical connections for a digital temperature controller include:

  1. Bekalan Kuasa: Connect the 230VAC power input to the designated terminals. Refer to the label on the device for exact terminal identification.
  2. Sambungan Sensor: Connect the temperature sensor chord to the sensor input terminals. Ensure a secure connection for accurate readings.
  3. Load Output (Heating/Cooling): Connect your heating or cooling device (e.g., compressor, heater) to the relay output terminals. Observe polarity and maximum current ratings.

Awas: Incorrect wiring can damage the device or connected equipment and poses an electrical hazard. If you are unsure about wiring, consult a qualified electrician.

4.2 Pemasangan

The controller is designed for panel mounting. Ensure adequate ventilation around the unit to prevent overheating. Cut an appropriate opening in the panel and secure the controller using the provided clips or mounting hardware.

5. Arahan Operasi

The SZ-7501 controller features a user-friendly interface for setting and monitoring temperature.

5.1 Hidupkan/Mati Kuasa

Connect the device to a 230VAC power source. The display will illuminate, showing the current temperature.

5.2 Setting the Desired Temperature (Set Point)

  1. Tekan ke SET button once. The display will flash, showing the current set point temperature.
  2. Gunakan ATAS (▲) dan TURUN (▼) buttons to adjust the set point to your desired temperature.
  3. Tekan ke SET button again to confirm and save the new set point. The display will return to showing the current temperature.

5.3 Programming Parameters (PRG)

The PRG button is used to access advanced settings such as temperature differential (hysteresis), compressor delay time, and calibration. Specific parameter codes and their functions are typically detailed in a separate programming guide or on the device itself.

  1. Tekan dan tahan butang PRG button for several seconds to enter programming mode.
  2. Gunakan ATAS (▲) dan TURUN (▼) buttons to navigate through the parameter codes (e.g., F1, F2, F3).
  3. Tekan SET kepada view the value of a selected parameter.
  4. guna ATAS (▲) dan TURUN (▼) to modify the parameter value.
  5. Tekan SET untuk menyimpan nilai baru.
  6. Tekan dan tahan PRG again, or wait for a timeout, to exit programming mode.

Nota: Refer to the specific parameter list for your model to understand each setting's function and appropriate range.

5.4 Reset Function (RST)

The RST button is typically used to reset alarms or to initiate a manual defrost cycle in certain applications. Consult the device's specific functionality for its exact use.

6. Penyelenggaraan

Regular maintenance ensures the longevity and accurate performance of your Sub-Zero SZ-7501 controller.

  • Pembersihan: Lap paparan dan casing dengan kain lembut dan kering. Jangan gunakan pembersih atau pelarut yang melelas.
  • Penjagaan Sensor: Ensure the temperature sensor is clean and free from debris. Avoid bending or damaging the sensor chord.
  • Sambungan: Periksa secara berkala semua sambungan elektrik untuk kesesakan dan tanda-tanda kakisan.
  • Persekitaran: Operate the controller within its specified environmental conditions (temperature, humidity) to prevent damage.

7. Penyelesaian masalah

This section addresses common issues you might encounter with your SZ-7501 controller.

MasalahKemungkinan PuncaPenyelesaian
Paparan kosongNo power supply; loose connection; internal fault.Check power connection (230VAC). Verify wiring. If problem persists, contact support.
Bacaan suhu tidak tepatSensor faulty; sensor not properly placed; calibration error.Check sensor connection and placement. Ensure sensor is not damaged. Consider recalibration if available in PRG settings.
Controller not switching load (heating/cooling)Incorrect set point; faulty relay; wiring error; compressor delay active.Verify set point and temperature differential. Check load wiring. Wait for compressor delay to expire.
Alarm indicator activeTemperature outside set limits; sensor error.Check current temperature and set limits. Verify sensor functionality. Press RST to clear alarm.

8. Spesifikasi

Nombor ModelSZ-7501
JenamaSub-Zero (Manufacturer)
Bekalan Kuasa230VAC (110V-220V compatible)
Julat Suhu-50°C hingga +99°C
Output GegantiSZ – 7510 P – 8 (3) A
Dimensi Produk (LxWxH)9 x 4 x 9 cm
Berat Barang62 g
warnaBlack and Purple
Negara AsalIndia

9. Waranti dan Sokongan

For warranty information and technical support, please refer to the documentation provided with your purchase or contact the retailer. Keep your purchase receipt as proof of purchase.

For further assistance, you may also visit the manufacturer's webtapak atau hubungi bahagian perkhidmatan pelanggan mereka.

Dokumen Berkaitan - SZ-7501

Praview SubZero SZ-PPA2 Pro Phono PraampManual Pengguna yang lebih hidup
Manual pengguna untuk SubZero SZ-PPA2 Pro Phono Praamplifier, memperincikan ciri, operasi dan spesifikasinya. Ketahui cara menyambung dan menggunakan peranti untuk prestasi audio yang optimum.
Praview Manual Pengguna Pakej Rakaman Rumah SubZero BASE-2
Manual pengguna untuk Pakej Rakaman Rumah SubZero BASE-2, yang menampilkan antara muka audio SZ-AI2, mikrofon SZC-300 dan fon kepala SZ-MH200. Ketahui tentang persediaan, ciri dan spesifikasi.
Praview Manual Pengguna Fon Kepala Pembatal Bunyi SubZero SZ-NH300BT
Manual pengguna yang komprehensif untuk Fon Kepala Pembatal Bunyi SubZero SZ-NH300BT, yang memperincikan ciri, persediaan, operasi, langkah berjaga-jaga keselamatan dan spesifikasi teknikal.
Praview Manual Pengguna Pek Antara Muka Audio SubZero BASE1
Manual pengguna yang komprehensif untuk Pek Antara Muka Audio SubZero BASE1, meliputi persediaan, fungsi, ciri dan spesifikasi teknikal antara muka audio (SZ-AI1), mikrofon pemeluwap (SZC-1) dan fon kepala pemantauan (SZ-MH1). Termasuk maklumat keselamatan dan butiran hubungan.
Praview Manual Pengguna Fon Kepala Pembatalan Bunyi Bluetooth Wayarles SZ-NH500BT SubZero
User manual for the SubZero SZ-NH500BT Wireless Bluetooth Noise Cancelling Headphones, covering important safety information, features, what's in the box, overview of components, operation of Active Noise Cancellation and Bluetooth, battery information, technical specifications, and support contact details.
Praview Manual Pengguna Fon Kepala Pembatal Bunyi SubZero NH300BT
Manual pengguna yang komprehensif untuk Fon Kepala Pembatal Hingar Bluetooth SubZero NH300BT, merangkumi ciri, fungsi, pengecasan, aplikasi dan spesifikasi.