Okin JLDQ-14 & JLDQ.14.270.114A

Okin Refined-R Model JLDQ-14 & JLDQ.14.270.114A Power Recliner Motor Actuator Replacement User Manual

For Models: JLDQ-14, JLDQ.14.270.114A, JLDQ.14.270.114F

pengenalan

This manual provides essential information for the installation, operation, maintenance, and troubleshooting of your Okin Refined-R Power Recliner Motor Actuator. This motor is designed as a direct replacement for Okin JLDQ.14.270.114A and can also replace JLDQ.14.270.114F series motors, with minor differences that do not affect functionality.

The actuator motor set includes one motor and one connector. The connector features a 2-pin plug with a clip, specifically designed for connection to the master motor or power supply.

Okin Refined-R JLDQ-14 Power Recliner Motor Actuator

Gambar 1: Lebihview of the Okin Refined-R JLDQ-14 Power Recliner Motor Actuator.

Persediaan dan Pemasangan

Before beginning installation, ensure your recliner's power is disconnected. It is crucial to verify that the replacement motor's brand and model match your existing unit to ensure compatibility with your recliner's frame, which has specific requirements for actuator dimensions, stroke, and plugs.

Pemeriksaan Keserasian:

  • Confirm your existing motor is an Okin JLDQ.14.270.114A or JLDQ.14.270.114F series.
  • Ensure the physical dimensions and plug type (2-pin with clip) are consistent with your recliner's requirements.
Close-up of Okin JLDQ-14 motor label with specifications

Rajah 2: Jarak dekat view of the motor's identification label, showing model and specifications.

Langkah Pemasangan:

  1. Putuskan Kuasa: Unplug the recliner from the wall outlet to prevent accidental operation during installation.
  2. Keluarkan Motor Lama: Tanggalkan motor lama daripada rangka kerusi malas dengan berhati-hati. Perhatikan cara ia dipasang dan disambungkan.
  3. Sambungkan Motor Baharu: Attach the new Okin motor to the recliner frame using the existing mounting points. Ensure it is securely fastened.
  4. Sambungan Palam: Connect the 2-pin plug from the new motor to the corresponding receptacle on your recliner's power supply or control box. Ensure the clip engages properly for a secure connection.
Close-up of the 2-pin power supply plug for the Okin recliner motor

Figure 3: Detail of the 2-pin plug for connecting to the power supply.

The installation process is designed to be straightforward. Once installed, the motor operates quietly.

Arahan Operasi

The Okin Refined-R motor actuator is an integral component of your power recliner, enabling smooth and controlled movement. Operation is typically controlled via the recliner's hand control or integrated buttons.

Operasi Standard:

  • Once installed and connected to power, use your recliner's standard controls (buttons or remote) to extend or retract the footrest and recline the backrest.
  • The motor is designed for intermittent use. Its operational frequency is specified as On 1 minute / Off 8 minutes. This duty cycle ensures the longevity and proper functioning of the motor by allowing it to cool down between operations. Avoid continuous operation beyond the recommended duty cycle.

Penyelenggaraan

To ensure the long-term performance and reliability of your Okin Refined-R motor actuator, periodic maintenance is recommended.

Petua Penyelenggaraan Umum:

  • Jaga kebersihan: Regularly inspect the motor and surrounding areas for dust, debris, or obstructions. Gently wipe clean with a dry cloth.
  • Semak Sambungan: Periodically inspect all electrical connections, especially the 2-pin plug, to ensure they are secure and free from damage.
  • Pelinciran: Motor ini secara amnya bebas penyelenggaraan dari segi pelinciran dalaman. Jangan cuba melincirkan komponen dalaman melainkan diarahkan secara khusus oleh sokongan Okin.
  • Elakkan Beban berlebihan: Do not exceed the recliner's weight capacity, as this can strain the motor and reduce its lifespan.

Menyelesaikan masalah

If your recliner is not functioning correctly after motor replacement, follow these troubleshooting steps:

Isu dan Penyelesaian Biasa:

  1. No Movement/Power:
    • First, troubleshoot the recliner's switch and power supply. Ensure the recliner is properly plugged into a working electrical outlet.
    • Periksa kord kuasa untuk sebarang kerosakan yang boleh dilihat.
    • Verify that the 2-pin plug from the motor is securely connected to the power supply.
  2. Motor Tidak Bertindak balas:
    • Ensure the motor model matches your recliner's requirements. While this motor can replace JLDQ.14.270.114F, slight differences might exist.
    • Inspect the motor's wiring for any pinches, cuts, or loose connections.
  3. Bunyi Luar Biasa:
    • Check for any obstructions around the motor or linkage mechanisms that might be causing friction or binding.
    • Ensure the motor is securely mounted and not vibrating against the frame.

If these steps do not resolve the issue, it is recommended to contact Okin customer support for further assistance.

Spesifikasi

Detailed technical specifications for the Okin Refined-R JLDQ.14.270.114A motor actuator:

CiriSpesifikasi
ModelJLDQ.14.270.114A (also replaces JLDQ.14.270.114F series)
PenampilanHitam (PA), Perak Putih (Aluminium)
Strok114 mm
Minimum Dimensions (Shrink)270 mm
Maximum Dimension (Extend)384 mm
Load (Push Force)1000 N
Kekerapan OperasiHidup 1 minit / Mati 8 minit
Sambungan2-pin plug with clip for master motor/power supply
Berat Barang2.77 paun
Dimensi Pakej14.37 x 6.3 x 4.65 inci
Graphic illustrating product features including dimensions and load capacity

Figure 4: Visual summary of key product specifications.

Waranti dan Sokongan

For information regarding warranty coverage or technical support, please refer to the official Okin website or contact their customer service directly. It is recommended to have your product model number (JLDQ.14.270.114A or JLDQ.14.270.114F) and purchase details available when contacting support.

Anda boleh mendapatkan maklumat lanjut dan butiran hubungan dengan melawati Kedai Okin di Amazon.

Dokumen Berkaitan - JLDQ-14 & JLDQ.14.270.114A

Praview Arahan Pemasangan untuk Kerusi Malas Angkat Kuasa YB2213
Panduan pemasangan langkah demi langkah untuk kerusi malas lif kuasa YB2213, termasuk kandungan pakej, langkah sambungan dan arahan pendawaian untuk kuasa dan alat kawalan jauh. Menampilkan fungsi haba dan urutan.
Praview Panduan Penyelesaian Masalah Sistem Okin: Pembaikan dan Penyelenggaraan Kerusi Lif
Panduan penyelesaian masalah yang komprehensif untuk Sistem Okin yang digunakan dalam kerusi lif. Belajar untuk mendiagnosis dan menyelesaikan isu biasa dengan kawalan tangan, transformer, motor dan kacang gelendong. Termasuk petua pemasangan.
Praview Sistem Tempat Duduk OKIN: Komponen untuk Perabot Bergerak
Katalog komprehensif sistem tempat duduk OKIN, termasuk mekanisme kerusi malas manual dan kuasa, mekatronik, kerusi lif, kerusi santai, penyandar kepala, sokongan lumbar, penggerak, telefon bimbit, suis dan aksesori untuk perabot gerakan.
Praview Panduan Penggantian Alat Kawalan Jauh OKIN HSW306 5-Pin ke 7-Pin
Arahan langkah demi langkah untuk menggantikan alat kawalan jauh kerusi malas 5-pin OKIN HSW306 dengan model 7-pin, termasuk pintasan pendawaian, langkah pemasangan dan aksesori yang disyorkan.
Praview Manual Pengguna Sistem Kawalan Jauh OKIN RF.31.24.01
Manual pengguna yang komprehensif untuk sistem kawalan jauh 22 kekunci OKIN RF.31.24.01, memperincikan fungsi butang, prosedur tetapan kedudukan dan komponen sistem untuk katil boleh laras.
Praview Arahan Ujian Pemalam Bluetooth untuk Penggerak OKIN EMONS
Arahan ujian terperinci untuk sistem Pemalam Bluetooth OKIN EMONS, meliputi persediaan, pengujian fungsi aplikasi, penyimpanan dan penarikan balik kedudukan memori serta amaran keselamatan. Termasuk senarai komponen dan langkah operasi.