pengenalan
This manual provides essential information for the safe and efficient operation of your Danby DPA050E2BDB-6 Portable Air Conditioner. Please read all instructions carefully before using the appliance and retain this manual for future reference. This unit is designed to provide cooling, dehumidification, and fan functions for indoor spaces.

Rajah 1: Depan view of the Danby DPA050E2BDB-6 Portable AC.
Ciri-ciri Produk
- Convenient 3-in-1 design: air conditioner, fan, and dehumidifier.
- 7,500 BTU (5,000 SACC) portable air conditioner cools spaces up to 150 square feet.
- R32 refrigerant: environmentally friendly, R32’s GWP (Global Warming Potential) is 3x lower than R410a.
- Powerful 2-speed fan.
- Dehumidifier mode with direct drain for continuous operation.
Maklumat Keselamatan
Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury to persons. Read all instructions before using the appliance. Do not operate any appliance with a damaged cord or plug, or after the appliance malfunctions or has been dropped or damaged in any manner. Return appliance to the nearest authorized service facility for examination, repair, or electrical or mechanical adjustment. Use only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
Kandungan Pakej
Please ensure all items are present and in good condition upon unpacking.
- Danby DPA050E2BDB-6 Portable AC Unit
- Alat Kawalan Jauh
- Hos Ekzos
- Window Installation Kit (adjustable panels)
- Manual Pemilik
Persediaan & Pemasangan
Penempatan
Place the unit on a flat, stable surface. Ensure there is at least 20 inches (50 cm) of space around the unit for proper air circulation. Do not place the unit near heat sources or in direct sunlight.

Figure 2: Unit dimensions for proper placement.
Pemasangan Kit Tingkap
The window kit is designed to fit most standard vertical or horizontal windows. Adjust the panels to fit your window opening, ensuring a secure and sealed fit to prevent air leakage. Use the provided screws to secure the panels in place if necessary.
Sambungan Hos Ekzos
Attach the exhaust hose to the designated outlet on the back of the unit. Extend the hose to reach the window kit, ensuring it is not kinked or bent sharply, which can restrict airflow and reduce efficiency. Secure the hose to the window kit adapter.
Arahan Operasi
Panel Kawalan
The unit features an intuitive top-mounted control panel with a digital display for easy operation.

Rajah 3: Atas view daripada panel kawalan.
Alat Kawalan Jauh
All functions available on the control panel can also be operated using the included remote control. Ensure the remote has working batteries and is pointed towards the unit for optimal response.
Modes: Cool, Fan, Dehumidifier
- Mod Sejuk: Select this mode for cooling. Adjust the desired temperature using the up/down arrows.
- Mod Kipas: Operates as a fan to circulate air without cooling. Choose between two fan speeds.
- Mod Penyahlembapan: Removes excess moisture from the air. This mode may require continuous drainage in high humidity environments.
Fungsi Pemasa
The 24-hour programmable timer allows you to set the unit to turn on or off automatically, helping to save energy and ensure comfort when needed.
Penyelenggaraan
Pembersihan Penapis
The unit is equipped with a reusable and washable filter. Regularly check and clean the filter to maintain optimal performance and air quality. To clean, remove the filter, rinse it under running water, and allow it to air dry completely before reinserting.

Rajah 4: Sisi view indicating filter access.
Saliran
The unit features an automatic water evaporation system, reducing the need for frequent manual drainage. However, in high humidity conditions or when using dehumidifier mode, manual drainage or continuous drainage via a hose may be required. Consult the manual for specific instructions on connecting a continuous drain hose.
Penyimpanan
Before storing the unit for an extended period, ensure it is completely drained of water and the filter is clean and dry. Store the unit in a cool, dry place, preferably in its original packaging or covered to protect it from dust.
Menyelesaikan masalah
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Unit tidak dihidupkan | No power supply; Power cord damaged | Check power outlet; Contact service for cord replacement |
| Unit tidak menyejukkan dengan berkesan | Dirty air filter; Room too large; Doors/windows open | Clean air filter; Ensure room size is within capacity; Close doors/windows |
| Kebocoran air | Drain plug not properly inserted; Unit tilted | Ensure drain plug is secure; Place unit on a level surface |
| Bunyi yang tidak biasa | Unit not on level surface; Obstruction in fan | Place unit on level surface; Check for obstructions and remove |
Spesifikasi
| Ciri | Perincian |
|---|---|
| Dimensi Produk | 12.6 x 12.6 x 26.36 inci |
| Berat Barang | 52.2 paun |
| Pengeluar | Danby |
| Nombor Model Item | DPA050E2BDB-6 |
| Faktor Bentuk | Mudah alih |
| Kapasiti | 25.9 Liter |
| Luas Lantai | 150 Kaki Persegi |
| Voltage | 115 Volt |
| Tahap Kebisingan | 54 Desibel |
| Kuasa Penyejukan | 7500 Unit Terma British |
| Ciri Khas | Auto-restart, Electronic controls |
| Nisbah Kecekapan Tenaga Bermusim (SEER) | 6.1 |
| warna | Hitam |
Waranti dan Sokongan
This product comes with 24 months parts and labor coverage. Installation and/or yearly maintenance (cleaning) are not covered under warranty. For support or warranty claims, please refer to the contact information provided in your purchase documentation or visit the Danby webtapak.