1. Pengenalan
The ANMEATE FC-IR100 is a versatile digital infrared thermometer designed for quick and accurate temperature measurement. It offers both non-contact forehead and in-ear measurement modes, making it suitable for adults, children, and babies. Additionally, it can measure the temperature of objects and ambient room temperature, providing a comprehensive solution for various needs.

Figure 1: ANMEATE FC-IR100 Digital Infrared Thermometer.
2. Ciri-ciri Utama
- Pengukuran Mod Dwi: Easily switch between forehead (non-contact) and ear (contact) modes.
- Cepat dan Tepat: Provides temperature readings in approximately 1 second.
- Intelligent Fever Indicator: Color-coded backlight (green, orange, red) indicates temperature status.
- Ingat Ingatan: Stores up to 35 previous readings for tracking temperature changes.
- Skrin LCD Besar: Clear and easy-to-read display with backlight for low-light conditions.
- Mute/Unmute Function: Option to silence the beeping sound for quiet measurements, especially useful for sleeping infants.
- Object and Room Temperature Measurement: Capable of measuring surface temperatures of objects and ambient room temperature.
- Suis Fahrenheit/Celsius: Togol antara unit suhu dengan mudah.

Gambar 2: Lebihview of thermometer features and uses.

Figure 3: Features for ease of use, especially with babies.
3. Persediaan
3.1 Pemasangan Bateri
The thermometer requires 2 AAA batteries (included). To install or replace batteries:
- Cari penutup petak bateri di bahagian belakang peranti.
- Luncurkan penutup ke bawah untuk membuka petak.
- Masukkan 2 bateri AAA, pastikan kekutuban (+/-) yang betul.
- Luncurkan penutup semula ke tempatnya sehingga ia mengklik dengan selamat.
3.2 Menukar Unit Suhu (°C/°F)
Untuk bertukar antara Celsius (°C) dan Fahrenheit (°F):
- Buka petak bateri.
- Locate the small toggle switch inside the compartment.
- Move the switch to select your desired unit (°C or °F).
- Tutup penutup petak bateri.

Figure 4: Location of the temperature unit toggle switch.
4. Arahan Operasi
4.1 Forehead Mode (Non-Contact)
This mode is ideal for quick and hygienic temperature checks without physical contact.
- Ensure the probe cover is attached to the thermometer.
- Press the "SCAN" button to turn on the device.
- Hold the thermometer approximately 0-3 cm (0-1.2 inches) from the center of the forehead.
- Press and release the "SCAN" button. The reading will appear on the LCD screen within 1 second.
- The backlight color will indicate the temperature status (see Section 5).

Figure 5: Forehead and Ear measurement modes.
4.2 Ear Mode (Contact)
For accurate in-ear measurements, ensure the probe is clean.
- Gently remove the probe cover from the thermometer. The device will automatically switch to ear mode.
- Carefully insert the probe into the ear canal.
- Press and release the "SCAN" button. The temperature reading will be displayed.
- The backlight color will indicate the temperature status (see Section 5).
- After use, clean the probe as described in Section 7.
4.3 Object Temperature Measurement
This mode allows you to measure the surface temperature of various objects, such as bath water or baby formula.
- With the device OFF, press and hold the "M" (Memory/Mute) button for a few seconds until the object mode icon appears on the screen.
- Point the thermometer at the object you wish to measure.
- Press and release the "SCAN" button. The object's surface temperature will be displayed.

Figure 6: Measuring object temperatures.
Nota: No official seller videos were available for direct embedding in this manual. Please refer to the detailed instructions above for operation.
5. Intelligent Fever Indicator
The ANMEATE FC-IR100 features a color-coded backlight system to quickly indicate temperature status:
- Lampu Hijau: Indicates a normal temperature (89.6°F - 99.2°F / 32°C - 37.3°C).
- Cahaya Jingga: Indicates a lighter fever (99.3°F - 100.3°F / 37.4°C - 37.9°C).
- Lampu Merah: Indicates a high fever (100.4°F - 109.2°F / 38°C - 42.9°C).

Figure 7: Visual representation of the Intelligent Fever Indicator.
6. Ingatan Ingatan
The thermometer can store up to 35 previous temperature readings, allowing you to monitor changes over time.
- To access stored readings, turn on the thermometer.
- Press the "M" (Memory/Mute) button repeatedly to cycle through the stored readings. Each press will display the next reading in chronological order, from most recent to oldest.
7. Penyelenggaraan
7.1 Pembersihan
- Thermometer Body: Wipe the body of the thermometer with a soft, dry cloth. If necessary, use a cloth lightly dampdisapu dengan air atau detergen lembut.
- Siasatan: The most critical part to clean is the probe. After each use, especially for ear measurements, gently wipe the probe with an alcohol swab or a cotton swab moistened with 70% isopropyl alcohol. Allow it to air dry completely before storing.
- Jangan rendam termometer dalam air atau sebarang cecair lain.
- Do not use abrasive cleaning agents or thinners.
7.2 Penyimpanan
- Simpan termometer di tempat yang sejuk dan kering, jauh dari cahaya matahari langsung dan suhu yang melampau.
- Jauhkan ia daripada kanak-kanak.
- If not in use for an extended period, remove the batteries to prevent leakage.
- Utilize the included pouch for protection during storage or travel.
8. Penyelesaian masalah
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Inaccurate/Inconsistent Readings | Incorrect measurement distance (forehead mode); dirty probe (ear mode); rapid temperature changes in environment; recent physical activity. | Ensure correct distance (0-3cm) for forehead. Clean probe thoroughly for ear. Allow device to acclimate to room temperature for 30 minutes. Avoid taking temperature immediately after strenuous activity or bathing. Take multiple readings for accuracy. |
| "Lo" atau "Hai" dipaparkan | Temperature is outside the measurable range; low battery. | Ensure proper technique. Check battery level and replace if low. |
| Peranti tidak dihidupkan | Bateri mati atau tidak dipasang dengan betul. | Check battery polarity. Replace batteries with new AAA batteries. |
| No sound/beeping | Mute function is activated. | Press the "M" (Memory/Mute) button to unmute the device. |
9. Spesifikasi
- Nombor Model: FC-IR100
- Julat Pengukuran:
- Body: 89.6°F - 109.2°F (32°C - 42.9°C)
- Object: 32°F - 212°F (0°C - 100°C)
- Ketepatan: ±0.4°F (±0.2°C) for body temperature
- Masa Pengukuran: Lebih kurang 1 saat
- Ingatan: Sehingga 35 bacaan
- Sumber Kuasa: 2 x bateri AAA (termasuk)
- Matikan automatik: After approximately 30 seconds of inactivity
- Dimensi: 6.65 x 1.97 x 1.93 inci
- Berat: 4.66 auns
- Bahan: plastik
- Jenis Paparan: LCD
- Ciri Khas: Penggera
- Komponen yang Disertakan: Thermometer, pouch
10. Waranti dan Sokongan
ANMEATE offers a 90-day money-back guarantee for this product. If you encounter any issues or have questions regarding the operation, maintenance, or performance of your FC-IR100 thermometer, please contact ANMEATE customer support. They are committed to providing assistance and ensuring customer satisfaction.
For support, please refer to the contact information provided with your product packaging or visit the official ANMEATE webtapak.




