1. Pengenalan
This manual provides detailed instructions for the installation, operation, and maintenance of the 3M CFSM1254 Commercial Point-of-Entry Water Softener. Please read this manual thoroughly before installation and operation to ensure proper function and safety.

Figure 1: The 3M CFSM1254 Commercial Point-of-Entry Water Softener unit.
2. Maklumat Keselamatan
Always observe the following safety precautions to reduce the risk of injury or damage to the product.
- Ensure all local plumbing and electrical codes are followed during installation.
- Turn off the main water supply and depressurize the system before performing any maintenance or installation.
- Do not operate the softener if any parts are damaged or missing.
- Use only genuine 3M replacement parts and accessories.
- Jauhkan daripada kanak-kanak.
3. Komponen Termasuk
Sahkan bahawa semua komponen hadir sebelum memulakan pemasangan:
- 3M CFSM1254 Water Softener Unit
- Tangki Air Garam
- Installation Kit (fittings, clamps, drain hose)
- Penyesuai Kuasa (jika berkenaan)
- Manual Pengguna (dokumen ini)
4. Persediaan dan Pemasangan
Follow these steps for proper installation of your 3M water softener:
- Pilih Lokasi: Select a dry, level area near the main water supply line and a drain. Ensure adequate space for maintenance.
- Sediakan Paip: Turn off the main water supply. Install a bypass valve system to allow for softener maintenance without interrupting water service.
- Connect Softener Unit: Connect the inlet and outlet ports of the softener to the main water line using appropriate plumbing fittings. Ensure connections are secure and leak-free.
- Install Drain Line: Connect the softener's drain port to a suitable drain (e.g., floor drain, utility sink) using the provided drain hose. Ensure an air gap is maintained to prevent back-siphonage.
- Connect Brine Tank: Position the brine tank near the softener unit. Connect the brine line from the softener to the brine tank.
- Tambah Garam: Fill the brine tank with water softener salt (sodium chloride or potassium chloride) according to the manufacturer's recommendations.
- Hidupkan kuasa: If applicable, connect the power adapter to the softener unit and plug it into a grounded electrical outlet.
- Permulaan Awal: Slowly open the main water supply valve. Check for leaks. Follow the initial programming steps outlined in the operating section to set time, hardness, and regeneration cycles.
5. Arahan Operasi
Your 3M CFSM1254 water softener operates automatically once programmed. Here are key operational aspects:
5.1. Panel Kawalan Selesaiview
Panel kawalan membolehkan anda view system status and adjust settings. Refer to the display for current time, regeneration status, and remaining capacity.
5.2. Programming Initial Settings
- Set Time of Day: Navigate to the time setting and adjust to the current time.
- Kekerasan air: Input your water hardness level (grains per gallon or ppm) into the system. This is crucial for efficient regeneration.
- Masa Penjanaan Semula: Set the preferred time for automatic regeneration, typically during periods of low water usage (e.g., 2:00 AM).
- Jenis Penjanaan Semula: Choose between metered (demand-initiated) or timed regeneration based on your water usage patterns. Metered is generally more efficient.
5.3. Manual Regeneration
You can initiate a manual regeneration cycle at any time by pressing the "Regenerate" button on the control panel. This is useful if you anticipate high water usage or notice a decrease in water softness.
6. Penyelenggaraan
Regular maintenance ensures the longevity and efficiency of your water softener.
6.1. Salt Level Monitoring
Check the salt level in the brine tank monthly. Ensure the salt level is always above the water level. Refill with appropriate water softener salt as needed.
6.2. Pembersihan Tangki Air Garam
Periodically (e.g., annually), clean the brine tank to remove any salt mushing or sediment buildup. Refer to the detailed cleaning instructions in the full manual for your specific model.
6.3. Resin Bed Cleaning (Optional)
If you experience iron or other mineral fouling, a resin cleaner can be used. Consult a professional or the full manual for instructions.
7. Penyelesaian masalah
This section provides solutions to common issues. For more complex problems, contact customer support.
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Air tidak lembut | Low salt level; incorrect hardness setting; bypass valve open; power outage. | Check salt level and refill; verify hardness setting; ensure bypass valve is closed; check power connection. |
| Excessive salt usage | Incorrect hardness setting; frequent regeneration cycles. | Verify hardness setting; adjust regeneration frequency or type (metered vs. timed). |
| Air dalam tangki air garam terlalu tinggi | Clogged drain line; faulty brine valve. | Check and clear drain line; inspect or replace brine valve. |
8. Spesifikasi
Technical specifications for the 3M CFSM1254 Water Softener:
- Pengeluar: 3M
- Nombor Model: CFSM1254
- Nombor Bahagian: 16145220159
- Berat Barang: 15 paun
- Dimensi Pakej: 18 x 15 x 8 inci
- Sumber Kuasa: Dikuasakan Hidraulik
- Komponen yang Disertakan: Pelembut Air
- Tarikh Mula-mula Tersedia: 5 Mac 2020
9. Waranti dan Sokongan
For warranty information, technical support, or to purchase replacement parts, please contact 3M Customer Service or visit the official 3M webtapak. Simpan resit pembelian anda sebagai bukti pembelian.
Sokongan dalam talian: www.3m.com
Perkhidmatan Pelanggan: Refer to 3M's official webtapak untuk nombor hubungan serantau.