This manual provides detailed instructions for the safe installation, operation, and maintenance of your ProCom Dual Fuel Ventless Gas Fireplace System with Mantle. This system is designed to operate efficiently using either Natural Gas (NG) or Liquid Propane (LP) and features a thermostat control for consistent heating. Please read all instructions carefully before installation and use.

ProCom Dual Fuel Ventless Gas Fireplace System with Mantle, Antique White

Imej: Depan view of the ProCom Dual Fuel Ventless Gas Fireplace System in Antique White, showcasing the mantle and the firebox with realistic logs and flames.

Maklumat Keselamatan

AMARAN: Pemasangan, pelarasan, pengubahan, servis atau penyelenggaraan yang tidak betul boleh menyebabkan kecederaan atau kerosakan harta benda. Rujuk manual ini. Untuk mendapatkan bantuan atau maklumat tambahan, rujuk pemasang yang berkelayakan, agensi perkhidmatan atau pembekal gas.

Persediaan dan Pemasangan

Membongkar dan Pemeriksaan

Carefully remove all components from the packaging. Inspect for any shipping damage. If any damage is found, contact your retailer immediately. Ensure all parts listed in the "What's in the Box" section are present.

Perhimpunan

Some assembly is required for the mantle and the fireplace insert. Refer to the general assembly instructions provided with the product. Ensure the fireplace insert is securely placed within the mantle.

ProCom Fireplace System installed in a living room

Image: The ProCom fireplace system integrated into a living room setting, demonstrating its aesthetic appeal.

Fuel Type Selection (Dual Fuel Technology)

This fireplace system is designed for use with either Natural Gas (NG) or Liquid Propane (LP). It is crucial to select the correct fuel type and ensure the appliance is configured accordingly before connecting to a gas supply.

Penting: Conversion between NG and LP must be performed by a qualified service technician. Incorrect conversion can lead to unsafe operation and void the warranty.

Gas inlet ports for Natural Gas (NG) and Liquid Propane (LP) with blue cap

Image: Close-up of the gas inlet ports, labeled NG (Natural Gas) and LP (Liquid Propane), showing the blue cap for LP. This indicates the current configuration or the port for LP connection.

Gas inlet ports for Natural Gas (NG) and Liquid Propane (LP) with yellow and blue caps

Image: Close-up of the gas inlet ports, labeled NG (Natural Gas) and LP (Liquid Propane), showing both yellow and blue caps. This illustrates the dual fuel capability and the distinct caps for each gas type.

Sambungan Gas

Connect the fireplace to the appropriate gas supply (Natural Gas or Liquid Propane) using approved gas connectors and fittings. Ensure all connections are tight and leak-free. A gas pressure test must be performed by a qualified technician.

Arahan Operasi

Permulaan Awal

  1. Pastikan injap bekalan gas terbuka.
  2. Press and hold the control knob (refer to image below) to the "PILOT" position.
  3. While holding the knob, press the Piezo ignitor button repeatedly until the pilot flame ignites.
  4. Continue to hold the control knob for approximately 30-60 seconds after the pilot ignites to allow the thermocouple to heat up.
  5. Release the control knob. If the pilot flame extinguishes, repeat steps 2-4.
Control knob for pilot and temperature settings, and Piezo ignitor button

Image: Close-up of the control panel showing the main control knob with settings for "OFF", "PILOT", and numbered temperature settings (1-5), alongside the Piezo ignitor button.

Thermostat Control Operation

Once the pilot is lit, turn the control knob to the desired temperature setting (1-5). The thermostat will automatically cycle the main burner on and off to maintain the set room temperature. Setting 1 is the lowest heat output, and setting 5 is the highest.

Shutting Down the Fireplace

  1. To turn off the main burner, turn the control knob to the "PILOT" position. The pilot flame will remain lit.
  2. To completely turn off the fireplace, turn the control knob to the "OFF" position. This will extinguish both the main burner and the pilot flame.
  3. For extended periods of non-use, it is recommended to close the main gas supply valve.

Penyelenggaraan

Pembersihan Am

Log Set Care

The ceramic fiber logs are designed for durability. Handle them carefully to avoid breakage. Do not rearrange the logs from their factory-set positions, as this can affect flame appearance and efficiency.

Pemeriksaan Tahunan

It is recommended to have the fireplace inspected annually by a qualified service technician to ensure proper operation and safety.

Menyelesaikan masalah

MasalahKemungkinan PuncaPenyelesaian
Juruterbang tidak akan menyala
  • Tanpa bekalan gas
  • Udara dalam talian gas
  • Pilot orifice clogged
  • Pencucuh tidak menyala
  • Ensure gas valve is open
  • Bleed air from line (consult technician)
  • Clean pilot orifice (consult technician)
  • Check ignitor wire connection, replace battery if applicable
Pilot lights but main burner will not ignite
  • Control knob not set to a temperature setting
  • Thermocouple not heating properly
  • ODS system activated
  • Turn control knob to a numbered setting
  • Hold pilot knob longer, ensure pilot flame engulfs thermocouple
  • Ensure adequate ventilation, clear any obstructions
Fireplace produces odors
  • New appliance burn-off
  • Dust or debris on burner
  • Operate at high setting for several hours (ensure ventilation)
  • Clean burner area (consult technician)

If troubleshooting steps do not resolve the issue, contact a qualified service technician or ProCom customer support.

Spesifikasi

CiriPerincian
JenamaProCom
Nama ModelDuel Fuel
Nombor Model ItemPCS150T-1-AW
Keluaran Haba15,000 Unit Terma British (BTU)
Liputan PemanasanSehingga 600 kaki persegi.
Jenis Bahan ApiGas Asli (NG) atau Propana Cecair (LP)
Kecekapan99.9% Vent Free
Jenis KawalanKawalan Termostat
Jenis PencucuhanBattery-assisted Piezo ignition
Ciri KeselamatanOxygen Depletion Sensor (ODS)
Dimensi Produk12.5"D x 28"W x 36.5"H
Berat Barang84.5 paun
bahanWood (mantle), Concrete (logs)
warnaPutih Antik
Komponen yang DisertakanBurner, Log Set, Mantel
Perhimpunan DiperlukanYes (General assembly instructions provided)

Maklumat Waranti

This ProCom Dual Fuel Ventless Gas Fireplace System is covered by a Waranti Terhad 1 Tahun. For specific terms and conditions, please refer to the warranty documentation included with your product or contact ProCom customer support.

Sokongan Pelanggan

For technical assistance, parts, or warranty claims, please contact ProCom customer support. Have your model number (PCS150T-1-AW) and purchase date available when contacting support.

Pengeluar: ProCom

Refer to the product packaging or the official ProCom webtapak untuk maklumat hubungan terkini.