1. Pengenalan
This manual provides comprehensive instructions for the installation, operation, and maintenance of the ELIWELL EWRC 500 NT HACCP Electronic Controller, Model RCS3UDTX20700. This device is designed for precise temperature regulation in industrial and commercial applications, particularly those requiring HACCP compliance. Please read this manual thoroughly before installation and operation to ensure safe and efficient use.
2. Maklumat Keselamatan
Sentiasa patuhi langkah keselamatan berikut:
- Pemasangan dan penyelenggaraan mesti dilakukan oleh kakitangan yang berkelayakan sahaja.
- Putuskan sambungan kuasa sebelum melakukan sebarang pendawaian atau penyelenggaraan.
- Ensure the power supply matches the controller's specifications (230V).
- Lindungi peranti daripada air, kelembapan dan suhu yang melampau.
- Jangan buka casing unless specifically instructed to do so by the manufacturer.
- Patuhi semua kod dan peraturan elektrik tempatan.
3. Produk Lebihview
The ELIWELL EWRC 500 NT is an advanced electronic controller featuring a digital display and intuitive button interface for easy parameter adjustment and monitoring. It is specifically designed for applications requiring HACCP protocol adherence.

Rajah 3.1: Depan view of the ELIWELL EWRC 500 NT HACCP Electronic Controller.
This image displays the front panel of the ELIWELL EWRC 500 NT HACCP Electronic Controller. The device is housed in a light grey, rectangular enclosure. The front panel features a dark grey rectangular display area with a digital readout, likely showing temperature or operational status. Below the display, the word "COLDFACE" is visible. To the right of the display, there are several control buttons arranged vertically. From top to bottom, these include: an "ESC" button with a snowflake icon, a "SET" button, a button with a light bulb icon, an "AUX" button with a down arrow, and an orange circular power button with a vertical line and circle icon. Above the "AUX" button, there is an up arrow button with a fan icon. The "eliwell" brand logo is visible in the upper left corner of the dark grey display area. The overall design suggests a robust and functional industrial control unit.
4. Pemasangan
4.1 Pemasangan
The controller is designed for panel mounting with dimensions of 213x318mm. Ensure adequate ventilation around the unit to prevent overheating. Secure the controller using the provided mounting clips or screws, ensuring a snug fit to prevent vibration.
4.2 Pendawaian
All wiring must comply with local and national electrical codes. Use appropriate gauge wires for the power supply and load connections. Refer to the wiring diagram below for correct terminal connections.
Note: A detailed wiring diagram is typically provided on the device itself or in a separate technical sheet. For specific terminal assignments, consult the product's technical documentation.
General Wiring Guidelines:
- Connect the 230V AC power supply to the designated power input terminals.
- Connect temperature probes to the sensor input terminals.
- Connect controlled loads (e.g., compressors, fans, heaters) to the relay output terminals.
- Pastikan semua sambungan selamat dan terlindung.
5. Persediaan
After successful installation and wiring, proceed with the initial setup:
- Hidupkan kuasa: Apply power to the controller. The display will illuminate, and the unit will perform a self-test.
- Paparan Awal: The display will typically show the current temperature reading from the primary probe.
- Accessing Parameters: Tekan dan tahan butang SET button for a few seconds to enter the parameter configuration menu.
- Navigasi: Gunakan Up dan Bawah arrow buttons to scroll through parameters.
- Melaraskan Nilai: Tekan SET to select a parameter, use Up/Bawah untuk menukar nilainya, kemudian tekan SET sekali lagi untuk mengesahkan.
- Menu Keluar: Tekan ke ESC button to exit the parameter menu and return to the main display.
6. Arahan Operasi
6.1 Operasi Asas
Once configured, the controller operates automatically based on the set parameters. The main display continuously shows the measured temperature.
- Viewing Setpoint: Tekan sebentar SET butang ke view the current temperature setpoint. Press ESC untuk kembali ke paparan utama.
- Manual Defrost (if applicable): Tekan dan tahan butang Pencairan button (often combined with ESC or a dedicated button with a snowflake icon) to initiate a manual defrost cycle.
- Fungsi Bantu: The AUX button may activate an auxiliary output or function, depending on configuration. Refer to parameter settings for details.
6.2 Parameter Configuration (Advanced)
The EWRC 500 NT offers a wide range of configurable parameters to fine-tune its operation. These include setpoints, differentials, defrost cycles, alarm thresholds, and probe calibration. Access these parameters as described in the "Setup" section.
Consult the detailed parameter list in the full technical manual for specific codes and their functions. Incorrect parameter settings can lead to improper operation or damage.
7. Penyelenggaraan
Regular maintenance ensures the longevity and accuracy of your controller.
- Pembersihan: Bersihkan panel hadapan dengan lembut, damp kain. Jangan gunakan pembersih atau pelarut yang melelas.
- Pemeriksaan: Periodically inspect wiring connections for looseness or corrosion.
- Probe Check: Verify that temperature probes are securely connected and free from damage.
- Kemas Kini Perisian: Semak pengeluar website for any available firmware updates. (Requires specialized tools and knowledge).
All internal maintenance or repairs should only be performed by authorized service personnel.
8. Penyelesaian masalah
Bahagian ini menyediakan penyelesaian kepada isu biasa. Untuk masalah yang tidak disenaraikan di sini, hubungi sokongan teknikal.
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Paparan kosong | No power supply; Incorrect wiring; Blown fuse. | Check power connections; Verify wiring against diagram; Replace fuse if necessary. |
| Bacaan suhu tidak tepat | Faulty probe; Incorrect probe type selected; Probe not properly installed. | Check probe connection; Verify probe type in parameters; Reinstall probe. |
| Controller not switching load | Incorrect setpoint/differential; Relay fault; Wiring issue to load. | Adjust parameters; Check load wiring; Contact service if relay is faulty. |
| Kod ralat dipaparkan | Specific system fault (e.g., probe error, memory error). | Refer to the full technical manual for specific error code meanings and remedies. |
9. Spesifikasi
| Ciri | Perincian |
|---|---|
| Model | EWRC 500 NT HACCP (RCS3UDTX20700) |
| Jenama | ELIWELL |
| Bekalan Kuasa | 230 V AC |
| Dimensi Pemasangan | 213 x 318 mm (Panel Mount) |
| Permohonan | Electronic Temperature Regulation, HACCP Compliant |
| Rujukan Pengeluar | 4251759903357 |
10. Waranti dan Sokongan
For warranty information, please refer to the terms and conditions provided at the time of purchase or contact your distributor. Technical support can be obtained through the manufacturer or authorized service centers.
Pengeluar: Gastroteileshop
ASIN: B07Z5LXQWH