HACH LPV445.97.00110

Manual Arahan Kolorimeter Poket Hach DR300

Model: LPV445.97.00110 | Brand: HACH

1. Pengenalan

The Hach DR300 Pocket Colorimeter is a portable, waterproof instrument designed for precise and reliable water quality testing. It maintains Hach's legacy of accuracy while offering modern data transfer capabilities. This manual provides essential information for setting up, operating, maintaining, and troubleshooting your DR300 Pocket Colorimeter, ensuring optimal performance for your chlorine measurement needs.

Hach DR300 Pocket Colorimeter with product information sheet

The Hach DR300 Pocket Colorimeter, designed for reliable and accurate water quality analysis.

2. Apa yang ada di dalam Kotak

Your Hach DR300 Pocket Colorimeter kit comes ready-to-use in a sturdy custom carrying case. Please verify that all the following components are included:

Note: Reagents for testing are not included and must be purchased separately.

Hach DR300 Pocket Colorimeter kit in its carrying case

The complete Hach DR300 kit, neatly organized in its durable carrying case.

3. Persediaan

Before first use, ensure the batteries are properly installed and prepare your sample cells for accurate measurements.

3.1 Pemasangan Bateri

The DR300 operates on 4 AAA batteries, which are typically included and pre-installed. If replacement is needed, open the battery compartment on the back of the unit and insert new batteries, observing polarity.

3.2 Preparing Sample Cells

For accurate results, it is crucial to properly clean your sample cells before each test. Even new cells should be cleaned to remove any manufacturing residues.

  1. Basuh sample cells three times with deionized water.
  2. Basuh sample cells at least twice with the sample water you intend to test. This prevents dilution of low-level analytes.
  3. Wipe the exterior of the sample cell with a lint-free Kimwipe or similar cloth to remove fingerprints, dust, or fibers. This ensures light passes through cleanly during measurement.
Hach DR300 Pocket Colorimeter showing its display and buttons

The Hach DR300 Pocket Colorimeter, ready for use.

4. Operating Instructions: Chlorine Test (Free Chlorine)

This section details the procedure for performing a Free Chlorine test using the DPD Free Chlorine Reagent powder pillows and your DR300 Colorimeter.

4.1 Zeroing the Instrument

  1. Fill a clean sample cell with 10 mL of your sampair le.
  2. Tutup sample cell and wipe its exterior with a Kimwipe.
  3. Open the lid of the DR300's sample petak.
  4. Masukkan s yang telah disediakanample cell into the compartment, aligning the key on the cell with the slot in the instrument.
  5. Close the instrument lid to minimize external light interference.
  6. Tekan ke SIFAR button (blue square button). The display will show "0.00" once zeroing is complete. This step teaches the instrument what a zero reading looks like for your specific water sample.
Hand holding the Hach DR300 Pocket Colorimeter

The compact Hach DR300 fits comfortably in hand for easy operation.

4.2 Adding Reagent and Measuring

  1. Keluarkan sample cell from the instrument and open its cap.
  2. Open one DPD Free Chlorine Reagent powder pillow. Gently tap the packet to ensure all powder is at the bottom.
  3. Carefully pour the entire contents of the powder pillow into the sampsel.
  4. Tutup sample cell and gently invert it several times to mix the reagent. Avoid vigorous shaking to prevent air bubbles, which can interfere with readings. The sample should turn pink if chlorine is present.
  5. Wipe the exterior of the sample cell again with a Kimwipe.
  6. Insert the reacted sample cell back into the DR300's compartment, aligning the key.
  7. Tutup penutup instrumen.
  8. Tekan ke BACA button (green checkmark button). The instrument will display the Free Chlorine concentration in mg/L. For Free Chlorine, the reading should be taken within 60 seconds of adding the reagent.
Person using the Hach DR300 Pocket Colorimeter in an industrial setting

The DR300 is suitable for use in various field environments.

4.3 Official Product Video: Chlorine Test Demonstration

This video, provided by Hach Company, demonstrates the process of performing a chlorine test using the DR300 Pocket Colorimeter, including sample preparation, zeroing, reagent addition, and reading the results.

Person using the Hach DR300 Pocket Colorimeter in a laboratory setting

Accurate measurements can be performed efficiently in a lab environment.

5. Penyelenggaraan

Proper maintenance ensures the longevity and accuracy of your DR300 Pocket Colorimeter.

5.1 Membersihkan Instrumen

5.2 Sample Cell Care

6. Penyelesaian masalah

If you encounter issues with your DR300, refer to the following common problems and solutions:

Masalah Kemungkinan Punca Penyelesaian
Bacaan Tidak Tepat Kotor sample cells, incorrect reagent, air bubbles, improper zeroing. Ensure cells are clean and lint-free. Use correct reagent for the test and sample volume. Avoid vigorous shaking. Re-zero the instrument before adding reagent.
Instrument Not Powering On Bateri mati atau tidak dipasang dengan betul. Gantikan bateri dengan bateri AAA baharu, memastikan kekutuban yang betul.
Paparan Mesej Ralat Specific error codes indicate different issues. Consult the full instruction manual for a complete list of error codes and their corresponding troubleshooting steps.

7. Spesifikasi

8. Waranti & Sokongan

The Hach DR300 Pocket Colorimeter is manufactured by Hach Company, a trusted name in water quality analysis. For specific warranty information, technical support, or to inquire about replacement parts and reagents, please refer to the official Hach Company website or contact their customer service directly. Protection plans may also be available for extended coverage.

Dokumen Berkaitan - LPV445.97.00110

Praview Arahan Kit Ujian Klorin Hach: Panduan Ringkas untuk Pengujian Kualiti Air
Panduan ringkas ini menyediakan arahan untuk menggunakan Kit Ujian Klorin Hach bagi mengukur paras klorin bebas atau jumlah keseluruhan dalam air. Ia merangkumi langkah penyediaan, prosedur terperinci dan notis penting untuk ujian kualiti air yang tepat.
Praview Hach Methods Quick Reference Guide: Chemical Analysis Instruments and Reagents
A comprehensive guide to Hach's chemical analysis methods, detailing test parameters, EPA approvals, instrument compatibility, and product numbers for water quality testing.
Praview Manual Pengguna HACH DR300
Manual pengguna yang komprehensif untuk fotometer penapis mudah alih HACH DR300, operasi terperinci, prosedur pengujian, penentukuran, penyelenggaraan dan penyelesaian masalah untuk analisis kualiti air.
Praview Cara Memprogram Semula Hach DR-3000 untuk Vial COD Accu-TEST
Arahan dan perkhidmatan untuk memprogram semula spektrofotometer atau kolorimeter Hach DR-3000 untuk menggunakan vial accu-TEST COD Bioscience, Inc. Termasuk sokongan dan butiran perkhidmatan pemprograman semula daripada Bioscience, Inc.
Praview Manual Pengguna Fotometer Penapis Mudah Alih Hach DR300
Manual pengguna untuk fotometer penapis mudah alih Hach DR300, perincian spesifikasi, maklumat am, pemasangan, operasi dan penyelesaian masalah untuk ujian air.
Praview Penganalisis Klorin Kolorimetrik Julat Ultra Rendah CL17sc Hach: Teknikal Lebih Lanjutview
Komprehensif berakhirview of the Hach Ultra Low Range CL17sc online colorimetric chlorine analyser. Details its applications in water quality monitoring, technical specifications, principle of operation, dimensions, and ordering information for industrial and utility use.