Came 8K01MP-012 AXI20K05

Came 8K01MP-012 AXI20K05 Swing Gate Kit Instruction Manual

For Swing Gates up to 2 Meters

1. Pengenalan

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Came 8K01MP-012 AXI20K05 Swing Gate Kit. This kit is designed for automating swing gates up to 2 meters in length per leaf, operating on a 24V DC system. Please read this manual carefully before proceeding with any installation or operation to ensure safe and correct use of the product.

The Came Axi motor combines advanced technical solutions with sophisticated electronics, ensuring consistent movement and linear slowdowns. This system is engineered for high performance, even under intensive use, providing a secure and reliable automation solution.

Came 8K01MP-012 AXI20K05 Swing Gate Kit components

Gambar 1: Lebihview of the Came 8K01MP-012 AXI20K05 Swing Gate Kit components.

2. Maklumat Keselamatan

WARNING: Improper installation or use can lead to serious injury or property damage. Always follow safety guidelines.

3. Kandungan Pakej

The Came 8K01MP-012 AXI20K05 kit includes the following components:

4. Panduan Pemasangan

This section outlines the general steps for installing the Came 8K01MP-012 AXI20K05 swing gate kit. Refer to the detailed diagrams and specific instructions provided with each component for precise measurements and connections.

4.1 Pemeriksaan Pra-Pemasangan

4.2 Motor Installation (001SWN20 AXI20DGS)

  1. Mount the motor brackets securely to the gate post and gate leaf according to the provided template. Ensure correct alignment for optimal gate movement.
  2. Attach the motors to the brackets. The motors should be level and allow for the full range of gate motion.
  3. Connect the motor cables to the control panel, following the wiring diagram.

Figure 2: Illustration of motor mounting on a gate post and leaf. (Image not provided, refer to product manual for detailed diagram).

4.3 Control Panel Installation (002ZL65)

  1. Install the control panel in a protected, easily accessible location, away from direct weather exposure.
  2. Connect the main power supply to the control panel.
  3. Connect the motor cables, photocells, flasher, and radio frequency board to the designated terminals on the control panel.

4.4 Photocell Installation (001DIR10)

  1. Mount the transmitter and receiver photocells opposite each other, ensuring a clear line of sight across the gate opening.
  2. Connect the photocell wiring to the control panel as per the wiring diagram.
  3. Test the photocells to ensure they detect obstructions correctly.

4.5 LED Flasher Installation (001KLED24)

  1. Mount the LED flasher in a visible location using the 001KIAROS wall mounting bracket.
  2. Connect the flasher to the control panel.

4.6 Gambarajah Pendawaian

A detailed wiring diagram is crucial for correct installation. Please refer to the specific diagram included with your 002ZL65 Control Panel. Ensure all connections are secure and correctly polarized.

Gambar 3: Cthample wiring diagram for the 002ZL65 control panel. (Image not provided, refer to product manual for detailed diagram).

5. Arahan Operasi

Once installed and configured, the gate system can be operated using the provided transmitters.

5.1 Programming Transmitters (001TOP-432EE)

To program the 001TOP-432EE transmitters with the 002ZL65 control panel:

  1. Access the programming mode on the 002ZL65 control panel (refer to the control panel manual for specific button sequences).
  2. Press the desired button on the 001TOP-432EE transmitter. The control panel will confirm successful programming (e.g., via an LED indicator or sound).
  3. Repeat for all desired transmitters.
  4. Exit programming mode on the control panel.

5.2 Operasi Asas

6. Penyelenggaraan

Regular maintenance ensures the longevity and safe operation of your Came swing gate kit.

7. Penyelesaian masalah

This section addresses common issues you might encounter. For more complex problems, contact a qualified technician.

Masalah Kemungkinan Punca Penyelesaian
Gate does not respond to transmitter. No power to control panel; Transmitter battery low/dead; Transmitter not programmed; Photocell obstruction. Check power supply; Replace transmitter battery; Reprogram transmitter; Clear photocell path.
Pintu berhenti atau berundur tanpa diduga. Photocell obstruction; Safety edge activated; Motor overload. Clear photocell path; Check safety edges; Reduce gate friction or consult technician.
LED flasher does not operate. Loose connection; Faulty bulb/LED; Control panel issue. Check wiring connections; Replace flasher unit; Consult control panel manual.
Pintu bergerak perlahan atau dengan kesukaran. Mechanical friction; Low voltage; Masalah motor. Lubricate gate hinges/moving parts; Check power supply; Contact technician.

8. Spesifikasi Teknikal

Ciri Spesifikasi
Product Model (Kit) 8K01MP-012 AXI20K05
Pengeluar datang
Gate Length (Max per leaf) 2 meter
Vol Operasitage 24V DC
Kekerapan Pemancar 433.92 MHz
Julat Photocell 10 meter
Component Model Number (e.g., control panel) 88001-0067 (Note: This may refer to a specific component within the kit, not the entire kit.)
Component Dimensions (e.g., control panel) 24 x 16 x 7 cm (Note: This may refer to a specific component within the kit.)
Component Weight (e.g., control panel) 240 g (Note: This may refer to a specific component within the kit.)
Bateri Diperlukan Yes (for transmitters)
Tarikh Tersedia Pertama 9 Mac 2019

9. Waranti dan Sokongan

For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact Came customer support directly. Warranty periods typically cover manufacturing defects under normal use.

For technical assistance, spare parts, or professional service, please contact your authorized Came dealer or visit the official Came website. Ensure you have your product model number and purchase date available when seeking support.

No official product videos from the seller were found in the provided data. For visual guides, please check the manufacturer's official channels or consult your installer.

Dokumen Berkaitan - 8K01MP-012 AXI20K05

Praview CAME ATS 8K01MP-0400 Panduan Persediaan Pantas Kit Automasi Gerbang Ayun
Panduan persediaan pantas yang komprehensif untuk kit automasi pintu swing CAME ATS 8K01MP-0400, memperincikan pemasangan, pentauliahan, ciri keselamatan dan aksesori pilihan untuk sistem pagar automatik.
Praview CAME ATS 8K01MP-0402 Panduan Persediaan Pantas Kit Automasi Gerbang Ayun
This guide provides a quick setup for the CAME ATS 8K01MP-0402 swing gate automation kit. It covers kit contents, safety instructions, typical gate setup, geometry, manual release, wiring, SIM card information, power-on, commissioning via app and panel, safety options, SIM replacement, and optional accessories. Designed for gates up to 400kg per leaf and 5m width.
Praview Manual Pemasangan Panel Kawalan CAME ZLX24SA/ZLX24SR
Manual pemasangan untuk panel kawalan CAME ZLX24SA dan ZLX24SR, direka untuk motor gear 24V dalam sistem pintu automatik. Menyediakan garis panduan keselamatan penting, spesifikasi teknikal, gambar rajah pendawaian dan arahan pengaturcaraan.
Praview Kit CAME ATS-P5 - Panduan Persediaan Pantas untuk Pintu Ayunan
Panduan persediaan ringkas yang komprehensif untuk Kit CAME ATS-P5, yang memperincikan pemasangan, keselamatan, pendawaian, pengaturcaraan dan aksesori untuk pintu pagar buaian sehingga 400kg setiap daun dan lebar 5m.
Praview Manual Pemasangan Panel Kawalan CAME ZLJ24
Manual pemasangan komprehensif untuk panel kawalan CAME ZLJ24, direka untuk pengendali pintu ayun 24V DC. Meliputi ciri teknikal, sambungan elektrik, pengaturcaraan, keselamatan dan penyelesaian masalah.
Praview Automasi Pintu Gelongsor CAME SDN4-SDN10 - Manual Pemasangan
Manual pemasangan komprehensif untuk sistem automasi pintu gelangsar CAME SDN4, SDN6, SDN8 dan SDN10, merangkumi keselamatan, pemasangan, pendawaian, pengaturcaraan dan penyelesaian masalah. Termasuk spesifikasi teknikal dan panduan operasi.