Mobiclinic Mobi 1

Manual Arahan Tilam Anti-Dekubitus Udara Bergantian Mobiclinic Mobi 1

Model: Mobi 1 | Brand: Mobiclinic

1. Pengenalan dan Lebihview

The Mobiclinic Mobi 1 Alternating Air Anti-Decubitus Mattress is designed to assist in the prevention and management of pressure ulcers (also known as bedsores or decubitus ulcers) for individuals who spend extended periods in bed. This system utilizes 130 individual air cells that alternately inflate and deflate, providing continuous pressure redistribution and promoting blood circulation.

Pressure ulcers are localized injuries to the skin and/or underlying tissue, usually over a bony prominence, as a result of pressure, or pressure in combination with shear. The Mobi 1 mattress aims to reduce the risk of these injuries by constantly changing the pressure points on the patient's body.

Mobiclinic Mobi 1 Alternating Air Anti-Decubitus Mattress with Compressor

Figure 1: Mobiclinic Mobi 1 Anti-Decubitus Mattress and Compressor Unit.

2. Maklumat Keselamatan

Please read all instructions and warnings carefully before using this product. Failure to follow instructions may result in injury or product damage. Always refer to the product label and any additional warnings provided with the packaging.

  • Ensure the mattress is placed on a stable, flat surface or a suitable articulated bed frame.
  • Do not use the mattress near open flames or sources of ignition. The mattress material is fire-retardant, but caution is always advised.
  • Keep the compressor unit away from water or excessive moisture.
  • Do not attempt to repair the compressor or mattress yourself beyond minor patching. Contact qualified personnel for repairs.
  • Ensure the patient's weight does not exceed the maximum recommended capacity of 135 kg.

3. Apa yang ada di dalam Kotak

Your Mobiclinic Mobi 1 package includes the following components:

  • Mobiclinic Mobi 1 Alternating Air Anti-Decubitus Mattress
  • Unit Pemampat
  • Air Hoses for connection
  • Repair Kit (includes patches)
  • Manual Arahan

4. Arahan Persediaan

Follow these steps to correctly set up your Mobiclinic Mobi 1 mattress system:

  1. Sediakan Katil: Place the mattress on top of a standard bed mattress. Ensure the bed surface is clean and free from sharp objects.
  2. Unfold the Mattress: Carefully unfold the anti-decubitus mattress over the existing bed mattress. Position it so that the air cells are facing upwards. The mattress features adaptable flaps on the sides to secure it under the main mattress, preventing slippage.
  3. Letakkan Pemampat: Hang the compressor unit securely at the foot end of the bed using the integrated hooks. Ensure it is stable and not prone to falling.
  4. Sambungkan Hos Udara: Connect the two air hoses from the mattress to the corresponding air outlets on the compressor unit. Ensure a snug fit to prevent air leakage.
  5. Sambungan Kuasa: Plug the compressor's power cord into a suitable electrical outlet.
Mobiclinic Mobi 1 mattress placed on a bed, showing side flaps for securing

Figure 2: Mattress placement on a bed, highlighting the adaptable side flaps for secure fitting.

Close-up of Mobiclinic Mobi 1 compressor unit showing power switch, pressure regulator, air outlets, and hanging hooks

Figure 3: Compressor unit with labeled controls and hanging hooks.

Video Persediaan dan Operasi

Video 1: Demonstrates the quick installation and operation of the Mobiclinic Mobi 1 mattress system, including compressor connection and pressure adjustment.

5. Arahan Operasi

Once the mattress system is set up, follow these steps for operation:

  1. Hidupkan kuasa: Turn on the compressor unit using the power switch (usually marked 'ON/OFF'). The compressor will begin to inflate the mattress.
  2. Laraskan Tekanan: Use the pressure regulator dial on the compressor to adjust the firmness of the mattress according to the patient's weight and comfort. Refer to the markings on the dial for guidance (e.g., 40 kg to 135 kg).
  3. Alternating Cycle: The mattress cells will inflate and deflate in an alternating pattern, typically every 6 minutes. This cycle ensures that pressure is continuously redistributed, preventing prolonged pressure on any single area of the body.
  4. Patient Placement: Once the mattress is adequately inflated and the pressure is set, the patient can be carefully placed on the mattress.
Close-up of Mobiclinic Mobi 1 mattress cells showing alternating inflation and deflation, suitable for Grade I pressure ulcers

Figure 4: Alternating air cells providing pressure relief, ideal for Grade I pressure ulcer prevention.

The compressor is designed for quiet operation, ensuring minimal disturbance to the patient. Its noise level is approximately 33-34 dB, comparable to a quiet conversation.

Illustration showing a sleeping dog and a decibel scale, indicating the quiet operation of the compressor at 30-40 dB

Figure 5: The compressor operates quietly, ensuring a peaceful environment.

6. Penyelenggaraan dan Pembersihan

Proper maintenance and cleaning will extend the life of your Mobiclinic Mobi 1 mattress system.

  • Cleaning the Mattress: The mattress is made from medical-grade PVC, which is waterproof and easy to clean. Wipe the surface with a damp cloth using a mild disinfectant solution. Ensure the mattress is completely dry before use. Do not immerse the mattress in water.
  • Membersihkan Pemampat: Wipe the exterior of the compressor unit with a dry or slightly damp kain. Jangan gunakan pembersih yang melelas atau rendam unit di dalam air.
  • Storan: If storing the mattress for an extended period, ensure it is clean and dry. Deflate the mattress completely, fold it neatly, and store it in a cool, dry place away from direct sunlight and sharp objects.
  • Kit Pembaikan: Use the provided repair patches for minor punctures in the mattress. Follow the instructions included with the repair kit.
Man resting on the mattress, with icons highlighting material properties: waterproof, easy to clean, secure, and fire retardant PVC

Figure 6: The mattress material is designed for durability, hygiene, and safety.

7. Penyelesaian masalah

If you encounter any issues with your Mobiclinic Mobi 1 mattress system, please refer to the following common troubleshooting tips:

  • Mattress not inflating or deflating properly:
    • Check if the compressor is powered on and plugged in.
    • Ensure all air hoses are securely connected to both the mattress and the compressor.
    • Inspect the mattress for any punctures or leaks. Use the repair kit for minor damages.
    • Verify the pressure regulator dial is set appropriately for the patient's weight.
  • Compressor making unusual noise:
    • Ensure the compressor is placed on a stable surface and not vibrating against anything.
    • Check if the air hoses are kinked or obstructed.
    • If the noise persists and is excessive, discontinue use and contact customer support.
  • Mattress feels too hard or too soft:
    • Adjust the pressure regulator dial on the compressor to achieve the desired firmness.
    • Allow sufficient time for the mattress to adjust to the new pressure setting.

For issues not covered here or if problems persist, please contact Mobiclinic customer support for assistance.

8. Spesifikasi

CiriSpesifikasi
ModelMobi 1
Dimensi Tilam (P x L x T)200 sm x 90 sm x 7 sm (anggaran)
Compressor Dimensions (L x W x H)23 cm x 11.15 cm x 10 cm
Jumlah Berat Produk2 kg
Compressor Weight1 kg
bahanMedical-grade PVC, Fire-retardant
Bilangan Sel Udara130
Alternating Cycle Time6 minutes (approximate)
Berat Pengguna Maksimum135 kg
Compressor Noise Level33-34 dB
Penggunaan yang DimaksudkanPrevention of Grade I pressure ulcers
Mobiclinic Mobi 1 mattress with dimensions labeled: 200 cm length, 90 cm width, 7 cm height, and maximum user weight of 135 kg

Figure 7: Key dimensions and weight capacity of the Mobi 1 mattress.

9. Waranti dan Sokongan

Mobiclinic has been providing quality healthcare products since 1985. We are committed to designing, innovating, and ensuring the safety of our products. For any questions, technical support, or warranty claims, please refer to the contact information provided with your purchase or visit the official Mobiclinic webtapak.

Sila simpan bukti pembelian anda untuk sebarang pertanyaan berkaitan waranti.

Dokumen Berkaitan - Mobi 1

Praview MOBICLINIC Coliseo Rollator: Manual Arahan dan Panduan Pengguna
Manual arahan yang komprehensif untuk rollator MOBICLINIC Coliseo, meliputi pemasangan, operasi, petua keselamatan dan penyelenggaraan. Direka untuk membantu warga emas dan individu yang mengalami kesukaran berjalan.
Praview Manual de Instrucciones Mesa Ajustable Auxiliar CUMBRE
Guía completa for el montaje, uso y mantenimiento de la mesa ajustable auxiliar CUMBRE de Mobiclinic. Menjelaskan ciri-ciri, faedah dan penyelesaian masalah komunes.
Praview Manual de Instrucciones Nebulizador de Malla NEBUMOBI 1
Este manual proporciona instrucciones detalladas para el uso seguro y eficaz del nebulizador de malla NEBUMOBI 1, un dispositivo médico diseñado para la administración de medicamentos por inhalación para el tratamiento de afecciones respiratorias. Incluye advertencias, precauciones, características técnicas y guías de mantenimiento.
Praview Manual de Instrucciones Jaula para Pájaros NINFA
Guía completa for el montaje, uso y mantenimiento de la jaula for pájaros NINFA, incluyendo characteristicas, componentes, dimensions, consejos de security and warrantía.
Praview Andador Bariátrico MADEIRA: Manual de Instrucciones y Uso Seguro
Manual melengkapkan arahan untuk Andador Bariátrico MADEIRA de Mobiclinic. Aprenda sobre montaje, uso seguro, precauciones, mantenimiento y solutions de problems for mejorar la movilidad.
Praview Manual Pengguna Treadmill MOBICLINIC TIBET
Manual pengguna yang komprehensif untuk treadmill MOBICLINIC TIBET, perincian pemasangan, operasi, spesifikasi teknikal, penyelenggaraan dan penyelesaian masalah untuk pengguna kecergasan di rumah.