Beckhoff KL2622

Beckhoff KL2622 Relay Output Terminal: 2-Channel, 2A, 230VAC User Manual

Model: KL2622

1. Pengenalan

This user manual provides essential information for the safe and efficient installation, operation, and maintenance of the Beckhoff KL2622 Relay Output Terminal. The KL2622 is a 2-channel digital output terminal designed for industrial control applications, providing two independent relay outputs capable of switching up to 2 Amps at 230 V AC/DC.

Please read this manual thoroughly before commencing any work with the device to ensure proper handling and to prevent potential hazards or damage.

2. Arahan Keselamatan

  • Installation and commissioning must only be carried out by qualified personnel familiar with electrical engineering and the relevant safety regulations.
  • Disconnect power from the system before performing any installation, wiring, or maintenance work.
  • Pastikan bahawa vol operasitage and current ratings of the KL2622 are not exceeded.
  • Lindungi peranti daripada kelembapan, habuk dan suhu yang melampau.
  • Do not open the housing of the terminal. There are no user-serviceable parts inside.
  • Proper grounding must be ensured for all connected components.

3. Produk Lebihview

The Beckhoff KL2622 is a Bus Terminal that provides two relay outputs. It is designed for direct connection to a bus coupler or other Bus Terminals within a Beckhoff Bus Terminal system. Each output features an LED indicator for status visualization.

Beckhoff KL2622 Relay Output Terminal, angled view

Rajah 3.1: bersudut view of the Beckhoff KL2622 Relay Output Terminal. This image shows the overall form factor, the terminal block connections, and the product labeling on the side.

The terminal features a compact design for DIN rail mounting and integrates seamlessly into existing Beckhoff I/O systems. The wiring diagram and specific product information are printed directly on the device housing for quick reference.

Atas view of Beckhoff KL2622 showing wiring diagram and product labels

Rajah 3.2: Atas view of the KL2622, highlighting the integrated wiring diagram for Output 1 and Output 2, along with the power supply connections and protective earth (PE). The product model number and serial number are also visible.

4. Spesifikasi

ParameterNilai
ModelKL2622
Bilangan Saluran2
Jenis OutputOutput Geganti
Menukar ArusUp to 2 A per channel
Penukaran VoltageUp to 230 V AC/DC
Pendawaian4-wire connection (for power and outputs)
PengeluarBeckhoff
Dimensi ProdukKira-kira 3 x 4 x 1 inci (7.6 x 10.2 x 2.5 cm)
Berat badanLebih kurang 1.51 paun (0.68 kg)

5. Persediaan dan Pemasangan

5.1 Pemasangan

The KL2622 terminal is designed for mounting on a standard 35 mm DIN rail. It should be snapped onto the DIN rail alongside a bus coupler and other Bus Terminals, ensuring proper mechanical and electrical connection.

5.2 Pendawaian

Before wiring, ensure all power supplies are disconnected. The KL2622 features screwless terminals for quick and secure wiring. Refer to the diagram printed on the terminal and Figure 5.1 for connection details.

sebelah view of Beckhoff KL2622 showing terminal block connections

Rajah 5.1: sebelah view of the KL2622, illustrating the terminal block connections. Wires are inserted into the openings and secured by pressing down the orange tab.

  1. Bekalan Kuasa: Connect the 230 V AC/DC power supply to the designated terminals. Ensure correct polarity if using DC.
  2. Output 1: Connect the load for Output 1 to the corresponding terminals.
  3. Output 2: Connect the load for Output 2 to the corresponding terminals.
  4. Protective Earth (PE): Ensure the protective earth connection is properly made to the PE terminal, if applicable to your system.

The terminal supports 4-wire connections, meaning separate connections for the power supply and each output, allowing for independent control and isolation.

6. Operasi

Once installed and wired correctly, the KL2622 operates under the control of the connected bus coupler and the higher-level control system (e.g., PLC). The relay outputs are switched based on the digital commands received from the control system.

6.1 Penunjuk LED

Each output channel on the KL2622 is equipped with an LED indicator:

  • DIPERLUKAN: Indicates that the corresponding relay output is active (closed).
  • LED MATI: Indicates that the corresponding relay output is inactive (open).

These LEDs provide a visual confirmation of the output status, aiding in commissioning and troubleshooting.

7. Penyelenggaraan

The Beckhoff KL2622 is designed for maintenance-free operation. However, periodic inspection of the wiring connections and the terminal's physical condition is recommended to ensure continued reliable performance.

  • Pembersihan: If necessary, clean the exterior of the terminal with a soft, dry, lint-free cloth. Do not use abrasive cleaners or solvents.
  • Semakan Sambungan: Periodically verify that all wire connections are secure and free from corrosion.
  • Keadaan Persekitaran: Pastikan persekitaran operasi kekal dalam julat suhu dan kelembapan yang ditetapkan.

No internal maintenance or user-serviceable parts are present. Any repairs should be handled by authorized Beckhoff service personnel.

8. Penyelesaian masalah

This section addresses common issues that may arise during the operation of the KL2622 terminal.

MasalahKemungkinan PuncaPenyelesaian
Output LED does not illuminate.
  • No power supply to the terminal.
  • No control signal from the bus coupler.
  • Faulty LED or internal component.
  • Periksa sambungan bekalan kuasa dan voltage.
  • Verify the control program and bus communication.
  • Replace the terminal if other checks fail.
Connected load does not switch.
  • Incorrect wiring of the load.
  • Load current/voltage exceeds specifications.
  • Damaged relay contact.
  • Inspect load wiring according to Figure 3.2.
  • Ensure load parameters are within 2A, 230V AC/DC.
  • If LED is on but load doesn't switch, the relay may be faulty; replace the terminal.
Terminal not recognized by bus coupler.
  • Improper seating on DIN rail.
  • Damaged contacts between terminals.
  • Re-seat the terminal firmly on the DIN rail.
  • Inspect the side contacts for damage.

9. Waranti dan Sokongan

Beckhoff Automation GmbH & Co. KG provides a standard warranty for its products. For specific warranty terms and conditions, please refer to the official Beckhoff website or contact your local Beckhoff sales and support representative.

For technical support, product inquiries, or service requests, please visit the official Beckhoff webtapak di www.beckhoff.com atau hubungi bahagian perkhidmatan pelanggan mereka.

Dokumen Berkaitan - KL2622

Praview Beckhoff EL3174-0090 TwinSAFE SC 4-Channel Analog Input Terminal
Datasheet for the Beckhoff EL3174-0090 TwinSAFE SC, a 4-channel analog input terminal supporting -10/0...+10 V and -20/0/+4...+20 mA signals with 16-bit resolution. Details technical specifications, features, and related products for industrial automation.
Praview EL6751 Master/Slave-Klemme für CANopen - Dokumentasi Technische Beckhoff
Dokumentasi technische umfassende für die Beckhoff EL6751 Master/Slave-Klemme für CANopen. Erfahren Sie mehr über Pemasangan, Konfigurasi, CANopen-Kommunikasi dan Fehlerbehebung für industrielle Automatisierungslösungen.
Praview Beckhoff TwinCAT 3 NC PTP TF50x0 Manual: Motion Control Configuration and Parameters
Beckhoff's TwinCAT 3 NC PTP (TF50x0) manual detailing motion control configuration, setup, and parameters for industrial automation. Covers quick start, axis configuration, motion parameters, PLC integration, and technical specifications.
Praview Beckhoff CB4055 Industrial Motherboard Manual
Detailed manual for the Beckhoff CB4055 industrial motherboard, covering features, specifications, connectors, BIOS settings, and technical data for control and automation engineering specialists.
Praview Manual Alat Perkhidmatan Beckhoff (BST) - Sandaran dan Pemulihan untuk PC Industri
Panduan komprehensif untuk menggunakan Alat Perkhidmatan Beckhoff (BST) untuk mencipta, memulihkan dan mengurus imej sistem pada PC Industri. Meliputi pemasangan, konfigurasi, akses jauh dan sokongan.
Praview Beckhoff TF4500 TwinCAT 3 Speech: Manual for Automation Speech Integration
Explore the Beckhoff TF4500 TwinCAT 3 Speech manual. Learn about integrating speech recognition (ASR) and speech output (TTS) into industrial automation systems. Covers installation, configuration, and PLC programming.