This manual provides essential information for the safe and efficient operation, installation, and maintenance of your PEDROLLO JSWm/2CX self-priming water pump. Please read these instructions carefully before installation or use and retain them for future reference.

Rajah 1: PEDROLLO JSWm/2CX Self-Priming Water Pump. This image shows the blue-colored pump unit with its motor housing and pump body, designed for efficient water transfer.
Maklumat Keselamatan
Sentiasa patuhi langkah berjaga-jaga keselamatan berikut untuk mengelakkan kecederaan atau kerosakan pada pam:
- Ensure the pump is installed by a qualified professional.
- Putuskan sambungan kuasa sebelum melakukan sebarang penyelenggaraan atau servis.
- Jangan kendalikan pam dengan cecair mudah terbakar atau menghakis.
- Lindungi pam daripada suhu beku.
- Ensure proper grounding of the electrical connection.
Produk Selesaiview
The PEDROLLO JSWm/2CX is a self-priming centrifugal pump designed for reliable water transfer. It is suitable for pumping clean water and liquids that are not chemically aggressive to the pump's components. Its self-priming capability allows it to draw water even when air is present in the suction line, making it ideal for domestic water supply, small to medium autoclave tank systems, and garden irrigation.
Ciri-ciri Utama:
- Self-priming design for efficient operation.
- Suitable for clean water and non-aggressive liquids.
- Robust construction with stainless steel components.
- Designed for continuous duty in domestic and garden applications.
Persediaan dan Pemasangan
Proper installation is crucial for the pump's performance and longevity. Consult a qualified technician for installation.
- lokasi: Install the pump in a dry, well-ventilated area, protected from direct sunlight and freezing temperatures. Ensure adequate space for maintenance.
- Pemasangan: Securely fasten the pump to a stable, level surface using appropriate bolts to minimize vibration.
- Paip:
- Use pipes of adequate diameter to minimize friction losses.
- Ensure all connections are airtight, especially on the suction side, to prevent air ingress.
- Install a foot valve with a strainer at the end of the suction pipe to prevent debris from entering the pump and to maintain prime.
- Install a gate valve on both the suction and discharge sides for isolation during maintenance.
- Sambungan Elektrik:
- Connect the pump to a suitable power supply (220-230V, 50Hz) as indicated on the motor's data plate.
- Ensure the electrical circuit is protected by a residual current device (RCD) and an appropriately rated circuit breaker.
- Verify proper grounding according to local electrical codes.
- Penyebuan: Before initial startup, completely fill the pump casing and the suction line with clean water through the priming port. This is essential for self-priming pumps to initiate operation.
Arahan Operasi
- Permulaan permulaan: After installation and priming, open the discharge valve fully. Switch on the power supply. The pump should start and begin to draw water.
- Operasi Berterusan: Monitor the pump for unusual noises or vibrations. Ensure the pump is not running dry, as this can cause severe damage.
- Menutup: To stop the pump, switch off the power supply. If the pump is part of an automatic system (e.g., with a pressure switch), it will start and stop automatically based on demand.
- Had Suhu:
- Liquid temperature: up to +40 °C.
- Ambient temperature: -10 °C to +40 °C.
Penyelenggaraan
Penyelenggaraan yang kerap memastikan prestasi optimum dan memanjangkan jangka hayat pam. Sentiasa putuskan bekalan elektrik sebelum penyelenggaraan.
- Pemeriksaan biasa: Inspect the pump and piping for leaks, corrosion, or damage.
- Pembersihan Penapis: Periodically clean the foot valve strainer to prevent blockages and maintain flow.
- Musim sejuk: In areas prone to freezing, drain the pump completely and store it in a warm, dry place, or insulate it adequately to prevent damage from ice expansion.
- Pemeriksaan Motor: Ensure the motor's cooling fins are free from dust and debris to prevent overheating.
Menyelesaikan masalah
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Pam tidak bermula | No power supply; Motor overload; Seized impeller. | Check power connection and circuit breaker; Reset thermal overload; Contact service technician. |
| Pam berjalan tetapi tiada air yang dihantar | Pump not primed; Air leak in suction line; Foot valve clogged; Suction lift too high. | Re-prime the pump; Check all suction connections for leaks; Clean foot valve strainer; Reduce suction lift if possible. |
| Aliran atau tekanan berkurangan | Partial blockage in piping; Worn impeller; Air in system. | Inspect and clear piping; Contact service technician for impeller replacement; Bleed air from system. |
| Bunyi atau getaran yang berlebihan | Cavitation (air in water); Loose mounting; Bearing wear. | Check for air leaks and ensure proper priming; Tighten mounting bolts; Contact service technician. |
Spesifikasi
| Parameter | Nilai |
|---|---|
| Model | JSWm/2CX |
| Jenama | Pedrollo |
| Kuasa (HP) | 1 HP |
| Voltage / Kekerapan | 220-230V / 50Hz |
| Kadar Aliran Maks | 70 Liter seminit |
| Julat Suhu Cecair | Sehingga +40 °C |
| Julat Suhu Ambien | -10 °C hingga +40 °C |
| bahan | Stainless Steel (pump body components) |
| ASIN | B07HMZ2DKQ |
| Kod Artikel Antarabangsa | 08052230012515 |
Note: The specification for "Power: 220 Watts" found in some product listings may refer to a specific component or a different metric. The pump's performance is rated at 1 HP.
Waranti dan Sokongan
For warranty information, technical support, or spare parts, please contact your authorized Pedrollo dealer or visit the official Pedrollo webtapak. Simpan resit pembelian anda sebagai bukti pembelian.
Pengeluar: PEDROLLO