Please read and understand all safety warnings and instructions before operating this heater. Failure to follow these instructions may result in fire, explosion, serious injury, or death.
- Pengudaraan: This heater requires adequate ventilation. Always operate in a well-ventilated area to prevent carbon monoxide poisoning. Do not use in unventilated spaces.
- Bahan api: Use only liquid propane (LP) gas. Ensure the propane tank is securely connected and free of leaks. Never use gasoline or other flammable fuels.
- Pembersihan: Maintain minimum clearances from combustible materials. Keep the heater clear of curtains, clothing, and other flammable objects.
- Outdoor/Well-Ventilated Indoor Use: This heater is designed for outdoor use or in well-ventilated indoor spaces such as construction sites, workshops, garages, and barns. It is not suitable for residential living areas.
- Ciri-ciri Keselamatan: This unit is equipped with advanced safety features including a thermocouple, high-temperature limit shut-off, and flame-out fuel cut-off. Do not bypass or modify these features.
- Amaran Proposisi 65: Produk ini mengandungi bahan kimia yang diketahui oleh Negeri California untuk menyebabkan kanser dan kecacatan kelahiran atau bahaya pembiakan lain.
- Sambungan Elektrik: Ensure the electrical supply matches the heater's requirements (120 Volts). The power cord is short; use an appropriate extension cord if necessary, ensuring it is rated for outdoor use and the heater's wattage.
WARNING: Risk of Fire or Explosion. Keep flammable materials away from the heater.
2. Produk Lebihview
The Remington REM-60V-GFA-O is a portable 60,000 BTU liquid propane forced air heater designed to warm spaces up to 1,500 square feet. Its heavy-duty steel construction ensures durability for demanding environments.
Figure 2.1: Remington REM-60V-GFA-O 60,000 BTU LP Forced Air Heater. This image shows the overall design of the heater, featuring its black body, yellow handle, and control panel.
Ciri-ciri Utama:
- Keluaran Haba: 60,000 BTUs, capable of heating up to 1,500 sq. ft.
- Pembinaan: Durable steel for job site resilience.
- mudah alih: Lightweight design (approximately 11 lbs) with a convenient carry handle.
- Tetapan Boleh Laras: Variable heat settings and adjustable heat angle.
- Pencucuhan: Electronic ignition for quick starting.
- Aksesori yang disertakan: 10-foot LP cylinder hose and regulator.
3. Arahan Persediaan
Follow these steps to safely set up your Remington LP Forced Air Heater.
- Bongkar: Carefully remove the heater and all components from the packaging. Verify all parts are present: heater unit, 10-foot LP cylinder hose, and regulator.
- Kedudukan: Place the heater on a firm, level surface in a well-ventilated area. Ensure adequate clearance from walls, ceilings, and combustible materials as specified in the safety section.
- Sambungkan Tangki Propana:
- Pastikan tombol kawalan pemanas berada dalam kedudukan "MATI".
- Connect the regulator end of the hose to a standard 20-pound (or larger) liquid propane tank (not included). Turn the connection counter-clockwise to tighten. Ensure a secure, leak-free connection.
- Sambungkan hujung hos yang satu lagi ke saluran masuk propana pada pemanas.
- Ujian Kebocoran: After connecting the propane tank, open the tank valve slowly. Apply a soap and water solution to all connections. If bubbles appear, there is a leak. Close the tank valve immediately and re-tighten connections. Repeat the test. Do not operate the heater if a leak is detected.
- Sambungan Elektrik: Plug the heater's power cord into a grounded 120V AC electrical outlet.
Figure 3.1: Close-up of the propane gas inlet on the heater. This image highlights the connection point for the LP cylinder hose and regulator, along with a warning label.
Figure 3.2: The Remington heater positioned in an outdoor environment, demonstrating a typical setup for operation.
4. Arahan Operasi
Once the heater is properly set up and connected, follow these steps to operate it.
- Open Propane Valve: Slowly open the valve on the propane tank fully.
- Mulakan Pemanas: Turn the control knob on the heater to the desired heat setting (e.g., '1' for low, '2' for medium, '3' for high). The electronic ignition will automatically attempt to light the burner.
- Verify Ignition: Confirm that the burner has ignited and a flame is present. If the heater does not ignite within 15 seconds, turn the control knob to 'OFF', wait 5 minutes, and repeat the ignition process.
- Laraskan Haba: Use the variable heat settings on the control knob to adjust the heat output as needed.
- Laraskan Sudut: The heater's angle can be adjusted to direct heat where it is most needed.
Figure 4.1: Close-up of the heater's control knob. This knob allows users to select variable heat settings from 0 (off) to 3 (high).
Figure 4.2: This image illustrates the adjustable heat angle mechanism and the location of the electronic ignition on the Remington heater.
Untuk Mematikan:
- Turn the control knob on the heater to the "OFF" position.
- Tutup injap pada tangki propana.
- Cabut plag pemanas dari soket elektrik.
- Benarkan pemanas sejuk sepenuhnya sebelum dialihkan atau disimpan.
5. Penyelenggaraan
Penyelenggaraan yang kerap memastikan prestasi optimum dan memanjangkan jangka hayat pemanas anda.
- Pembersihan: Ensure the heater is unplugged and completely cool before cleaning. Wipe the exterior surfaces with a damp kain. Jangan gunakan pembersih atau pelarut yang melelas.
- Pemeriksaan: Periodically inspect the propane hose and connections for signs of wear, damage, or leaks. Replace any damaged components immediately.
- Storan: When not in use, store the heater in a dry, safe place, away from children and pets. Disconnect the propane tank and store it separately in a well-ventilated area.
6. Penyelesaian masalah
Jika pemanas anda tidak beroperasi dengan betul, rujuk jadual berikut untuk isu dan penyelesaian biasa.
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Pemanas tidak menyala. | No propane flow; electrical issue; ignition failure. | Check propane tank valve is open. Ensure hose connections are secure. Verify power cord is plugged in. Wait 5 minutes and retry ignition. |
| Pemanas menyala tetapi api padam. | Low propane pressure; safety shut-off activated; insufficient ventilation. | Check propane tank level. Ensure adequate ventilation. Inspect for blockages. |
| Keluaran haba yang tidak mencukupi. | Low heat setting; low propane level; heater too small for space. | Adjust control knob to a higher setting. Check propane tank level. Ensure heater is appropriate for the area size. |
| Heater is excessively noisy. | Normal operation for forced air heaters; fan obstruction. | Some noise is normal. Ensure no objects are obstructing the fan. |
Jika masalah berterusan selepas mencuba penyelesaian ini, hubungi sokongan pelanggan.
7. Spesifikasi
Technical specifications for the Remington REM-60V-GFA-O LP Forced Air Heater.
| Ciri | Perincian |
|---|---|
| Jenama | Remington |
| Nombor Model | REM-60V-GFA-O |
| Keluaran Haba | 60,000 BTU/jam |
| Liputan Pemanasan | Sehingga 1,500 kaki persegi |
| Jenis Bahan Api | Propana Cecair (LP) |
| Voltage | 120 Volt |
| Dimensi Produk | 19"D x 7.5"W x 13"H |
| Berat Barang | 13.97 paun |
| Penggunaan Dalaman/Luar | Outdoor (or well-ventilated indoor spaces) |
| Ciri Khas | High temperature limit shut-off, flame-out fuel cut, thermocouple, continuous electronic ignition |
| Komponen yang Disertakan | 10 ft. propane cylinder hose, Regulator |
Figure 7.1: Diagram illustrating key specifications and dimensions of the Remington 40-60 model, including weight, heating area, heating capacity, frequency, and voltage.
8. Maklumat Waranti
This Remington heater comes with a Waranti Terhad 1 Tahun dari tarikh pembelian. Waranti ini melindungi kecacatan pada bahan dan mutu kerja di bawah penggunaan biasa.
The warranty does not cover damage resulting from misuse, abuse, accident, unauthorized repairs, or normal wear and tear. For specific terms and conditions, please refer to the warranty card included with your product or contact Remington customer support.
9. Sokongan Pelanggan
For technical assistance, warranty claims, or questions regarding your Remington REM-60V-GFA-O heater, please contact Remington customer support.
Please have your model number (REM-60V-GFA-O) and purchase date available when contacting support.
Sumber Tambahan:
- For product registration and additional information, visit the official Remington webtapak.
- Consult the full product manual for detailed diagrams and safety warnings.
10. Video Produk
Tonton video ini untuk visual seterusnyaview of the Remington LP Forced Air Heater.
Video 10.1: An official product video demonstrating features and operation of the Remington Forced Air Heater.