1. Pengenalan
Thank you for choosing the Cata CIB 6021 BK Gas Hob. This appliance is designed to provide efficient and reliable cooking performance with its three high-power burners and elegant black glass finish. This manual provides essential information for the safe installation, operation, maintenance, and troubleshooting of your new gas hob. Please read it thoroughly before use and keep it for future reference.
2. Maklumat Keselamatan
Your safety and the safety of others are paramount. Please observe all safety warnings and instructions to prevent personal injury or property damage.
- Keselamatan Gas: This appliance is designed for use with Butane Gas. Ensure proper ventilation in the kitchen area. Do not store flammable materials near the hob. In case of a gas leak, immediately shut off the gas supply, open windows, and do not operate electrical switches or appliances.
- Pemasangan: Installation must be performed by a qualified technician in accordance with local regulations and standards. Incorrect installation can lead to gas leaks, fire, or electric shock.
- Kanak-kanak dan Haiwan Kesayangan: Keep children and pets away from the appliance during operation and when it is hot.
- Permukaan Panas: Burners and pan supports become very hot during use. Always use oven mitts or pot holders when handling hot cookware or components.
- Pembersihan: Always allow the hob to cool down completely before cleaning. Disconnect from the power supply if possible before cleaning.
- Pengudaraan: Ensure adequate ventilation in the kitchen when the hob is in use to prevent the build-up of combustion products.
- Terlalu panas: Do not leave cooking unattended, especially when frying with oil or fat, as overheating can lead to fire.
3. Komponen Produk
The Cata CIB 6021 BK Gas Hob consists of the following main components:
- Permukaan Kaca: Durable black glass surface for easy cleaning and modern aesthetics.
- Pembakar: Three gas burners, including one triple crown burner (3.5 kW), one semi-rapid burner (1.75 kW), and one auxiliary burner (1 kW).
- Enameled Pan Supports: Robust enameled grates designed to support cookware securely over the burners.
- Tombol Kawalan: Three control knobs with integrated electronic ignition for precise flame adjustment.
- Safety Valves: Integrated safety valves that cut off the gas supply if the flame accidentally extinguishes.

Rajah 3.1: Sudut hadapan view of the Cata CIB 6021 BK Gas Hob.

Figure 3.2: Key features of the Cata CIB 6021 BK Gas Hob.
4. Pemasangan
Proper installation is crucial for the safe and efficient operation of your gas hob. It must be carried out by a qualified and authorized technician.
4.1. Pemeriksaan Pra-Pemasangan
- Verify that the gas supply type (Butane Gas) matches the appliance's specifications.
- Ensure the kitchen area has adequate ventilation.
- Check that the countertop material is heat-resistant.
4.2. Countertop Cut-out Dimensions
Refer to the diagram below for the precise cut-out dimensions required for your countertop. The hob dimensions are approximately 59 cm (width) x 51 cm (depth).

Figure 4.1: Installation dimensions and gas inlet location.
4.3. Sambungan Gas
The gas inlet is located on the rear right side of the appliance. Use appropriate gas fittings and ensure all connections are leak-free. Butane gas injectors are included in the box for proper adaptation.
4.4. Sambungan elektrik
The hob requires an electrical connection for the electronic ignition system. Ensure the voltage and frequency match your household supply. A dedicated circuit is recommended.
5. Operasi
Operating your Cata gas hob is straightforward. Follow these steps for safe and effective use.
5.1. Lighting a Burner
- Place your cookware centrally on the desired pan support.
- Push down the corresponding control knob and turn it counter-clockwise to the maximum flame position (large flame symbol).
- Hold the knob down for a few seconds (typically 3-5 seconds) to allow the thermocouple to heat up and activate the safety valve. You will hear a clicking sound as the electronic ignition sparks.
- Once the flame is stable, release the knob. If the flame extinguishes, repeat the process, holding the knob down slightly longer.

Figure 5.1: Gas hob with burners ignited.
5.2. Adjusting the Flame
Once the burner is lit, you can adjust the flame intensity by rotating the control knob between the maximum and minimum flame positions. Do not force the knob beyond these limits.
5.3. Turning Off a Burner
To turn off a burner, rotate the control knob clockwise until it clicks into the "off" position (dot symbol).
6. Pembersihan dan Penyelenggaraan
Pembersihan dan penyelenggaraan yang kerap akan memastikan jangka hayat dan prestasi optimum dapur gas anda.
6.1. Pembersihan Harian
- Biarkan dapur sejuk sepenuhnya sebelum dibersihkan.
- Wipe the glass surface with a soft cloth and a mild detergent or glass cleaner. Avoid abrasive cleaners or scouring pads.
- Clean spills immediately to prevent them from drying and becoming harder to remove.
6.2. Cleaning Enameled Pan Supports and Burners
- Remove the pan supports and burner caps/crowns when they are cool.
- Wash them with warm soapy water. For stubborn stains, a non-abrasive cleaner can be used.
- Ensure all parts are thoroughly dry before reassembling them. Moisture can affect ignition.
6.3. Penyelenggaraan Am
- Periodically check the gas hose and connections for any signs of wear or leaks.
- Ensure the burner holes are not clogged. Use a fine brush or needle to clear any debris if necessary.
7. Penyelesaian masalah
Sebelum menghubungi perkhidmatan pelanggan, sila rujuk kepada isu biasa berikut dan penyelesaiannya:
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Pembakar tidak menyala. | No gas supply, clogged burner, faulty ignition, or not holding knob long enough. | Check gas supply. Clean burner holes. Hold knob down for 3-5 seconds. If issue persists, contact a technician. |
| Flame is irregular or yellow. | Clogged burner holes or incorrect gas pressure. | Clean burner holes. If the problem continues, contact a qualified technician to check gas pressure. |
| Bau gas dikesan. | Kebocoran gas. | Immediately shut off gas supply. Open windows. Do not operate electrical switches. Contact emergency services and a qualified technician. |
| Electronic ignition continuously clicks. | Moisture on burner, faulty ignition switch. | Ensure burner parts are dry. If problem persists, contact customer service. |
8. Spesifikasi
Detailed technical specifications for the Cata CIB 6021 BK Gas Hob:
| Ciri | Spesifikasi |
|---|---|
| Nombor Model | CIB 6021 BK (8068402) |
| Jenama | Cata |
| Bilangan Pembakar | 3 |
| Burner Types & Power | Left: 1 Triple Crown (3.5 kW) Right Top: 1 Semi-Rapid (1.75 kW) Right Bottom: 1 Auxiliary (1 kW) |
| Jumlah Kuasa | 6.25 kW |
| Jenis Bahan Api | Butane Gas (Natural Gas conversion possible with appropriate injectors, but product is prepared for Butane) |
| Jenis Pencucuhan | Electronic ignition integrated into control knobs |
| Ciri Keselamatan | Safety valves (gas cut-off system) |
| Bahan Permukaan | Seramik Kaca |
| warna | Hitam |
| Dimensi Produk (L x W x H) | 51 x 58.39 x 10.01 cm (approx. 59 cm width) |
| Berat badan | 2 kg |
| Termasuk Aksesori | Enameled grates/burners, Butane Gas injectors |
9. Waranti dan Sokongan
For warranty information, technical support, or service requests, please contact Cata customer service or refer to the warranty card included with your product. Ensure you have your model number (CIB 6021 BK) and purchase date available when contacting support.
You can visit the official Cata webtapak untuk maklumat lanjut dan sumber sokongan: www.cata.es