This manual provides essential information for the installation, operation, and maintenance of your Vaillant ECOTEC PURE VMW 246/7-2 condensing boiler. Please read this manual thoroughly before attempting any installation or operation to ensure safe and efficient use of the appliance.
The Vaillant ECOTEC PURE VMW 246/7-2 is a methane-powered condensing boiler designed for both central heating and instantaneous domestic hot water production. It features an intuitive user interface, a high-efficiency modulating pump, and a durable primary steel exchanger.

Rajah 1: Depan view of the Vaillant ECOTEC PURE VMW 246/7-2 condensing boiler. The unit is white with the Vaillant logo prominently displayed. A digital display shows '50' and control buttons are visible below it.
2. Arahan Keselamatan
Penting: Failure to follow these safety instructions could result in property damage, personal injury, or death. Keep this manual in a safe place for future reference.
- Installation and maintenance must only be carried out by a qualified and certified technician in accordance with local regulations and standards.
- Jangan simpan bahan mudah terbakar berhampiran dandang.
- Ensure adequate ventilation in the room where the boiler is installed.
- If you smell gas, immediately shut off the gas supply, open windows and doors, and contact a qualified technician. Do not operate any electrical switches.
- Jangan tamper with the boiler's internal components.
- Jauhkan kanak-kanak dan haiwan peliharaan dari perkakas.
3. Pemasangan dan Persediaan
3.1 Pemeriksaan Pra-Pemasangan
- Verify that the gas supply type (methane) matches the boiler's requirements.
- Ensure the installation site meets all local building codes and ventilation requirements.
- Confirm that the electrical supply is compatible with the boiler's specifications.
- Unpack the boiler carefully and inspect for any shipping damage.
3.2 Mounting the Boiler
- Select a suitable wall location capable of supporting the boiler's weight (approximately 20 kg).
- Use the provided mounting template (if applicable) to mark drilling points for the wall bracket.
- Securely fasten the wall bracket to the wall using appropriate fixings.
- Carefully lift and hang the boiler onto the wall bracket.
3.3 Connecting Utilities
- Sambungan Gas: Connect the methane gas supply line to the boiler's gas inlet, ensuring all connections are gas-tight and tested for leaks.
- Sambungan Air: Connect the central heating flow and return pipes, and the domestic hot water inlet and outlet pipes. Ensure proper isolation valves are installed.
- Longkang Kondensat: Connect the condensate drain line to an appropriate waste system, ensuring a continuous downward slope.
- Sistem asap: Install the flue system according to manufacturer instructions and local regulations for safe exhaust gas discharge.
- Sambungan Elektrik: Connect the boiler to the electrical supply, ensuring proper grounding and circuit protection.
3.4 Initial Filling and Venting
- Fill the heating system with water to the recommended pressure (typically 1.0-1.5 bar), monitoring the pressure gauge.
- Vent all radiators and the boiler itself to remove air from the system.
- Check for any leaks in the entire system.
4. Arahan Operasi
4.1 Antara Muka Pengguna Overview
The ECOTEC PURE VMW 246/7-2 features an intuitive user interface with a digital display and control buttons. The display shows current operating status, temperature settings, and error codes.
- Paparan Digital: Shows temperature, pressure, and status codes.
- Butang Mod: Toggles between heating, hot water, or standby modes.
- Butang Pelarasan Suhu (+/-): Used to increase or decrease desired heating or hot water temperatures.
- Butang Tetapkan Semula: Used to clear certain error codes after rectifying the fault.
4.2 Memulakan Dandang
- Ensure the gas supply is open and the electrical supply is connected.
- Check that the system pressure is within the recommended range (1.0-1.5 bar).
- Press the power button (if present) or ensure the boiler is switched on at the mains.
- Select the desired operating mode (e.g., heating and hot water).
- Set the desired heating and hot water temperatures using the adjustment buttons.
4.3 Connecting a VSMART Thermostat
The Vaillant ECOTEC PURE VMW 246/7-2 is compatible with the Vaillant VSMART thermostat for enhanced control and energy efficiency. Refer to the VSMART thermostat's separate instruction manual for detailed pairing and operation instructions.
5. Penyelenggaraan
Regular maintenance is crucial for the safe, efficient, and long-lasting operation of your Vaillant boiler. Only qualified technicians should perform maintenance tasks.
5.1 Annual Servicing
- It is recommended to have your boiler serviced annually by a Vaillant-certified technician.
- Annual servicing includes checking combustion efficiency, gas pressure, safety devices, and cleaning internal components.
5.2 User Checks
- Tekanan Sistem: Regularly check the system pressure on the boiler's display. If it falls below 1.0 bar, repressurize the system according to the instructions in Section 3.4 or consult a technician.
- Pemeriksaan Visual: Periodically inspect the boiler for any visible leaks, unusual noises, or changes in performance.
- Longkang Kondensat: Ensure the condensate drain is clear and not blocked.
6. Penyelesaian masalah
This section provides solutions to common issues. For complex problems or if an error persists, contact a qualified service technician.
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Tiada pemanasan atau air panas | Low system pressure, no gas supply, power outage, thermostat setting too low. | Check system pressure and repressurize if needed. Ensure gas valve is open. Check electrical supply. Adjust thermostat settings. |
| Boiler displaying an error code | Various internal faults. | Note the error code and consult the full technical manual or contact a qualified technician. Try pressing the Reset button once. |
| Unusual noises from the boiler | Udara dalam sistem, masalah pam, pembentukan kerak kapur. | Vent radiators. If noise persists, contact a qualified technician. |
| Kebocoran air | Sambungan longgar, komponen rosak. | Immediately turn off the water supply to the boiler and contact a qualified technician. |
| Pilot light (if applicable) not igniting | No gas supply, ignition fault. | Check gas supply. If problem persists, contact a qualified technician. |
| Reduced hot water flow or temperature | Limescale buildup, faulty sensor, low water pressure. | Check water pressure. Contact a qualified technician for inspection and descaling if necessary. |
7. Spesifikasi Teknikal
| Ciri | Spesifikasi |
|---|---|
| Model | ECOTEC PURE VMW 246/7-2 |
| Nombor Bahagian | 0010019985 |
| Jenama | Vaillant |
| Jenis Bahan Api | Metana (Gas Asli) |
| Output Pemanasan | 24 kW |
| Domestic Hot Water Output | 28 kW (Instantaneous) |
| Jenis Pam | Modulating 1:4 (Class A) |
| Primary Exchanger Material | Keluli |
| Kapasiti Kapal Pengembangan | 8 Liter |
| Dimensi (H x W x D) | 80 sm x 50 sm x 40 sm (anggaran) |
| Berat badan | 20 kg |
| Penilaian Kecekapan Tenaga | A |
| Keserasian | VSMART Thermostat |
8. Waranti dan Sokongan
8.1 Maklumat Waranti
Vaillant products are covered by a manufacturer's warranty. The specific terms and duration of the warranty may vary by region and purchase date. Please refer to the warranty card included with your product or visit the official Vaillant webtapak untuk maklumat terperinci.
Nota: Improper installation, unauthorized repairs, or failure to perform regular maintenance may void your warranty.
8.2 Sokongan Teknikal
For technical assistance, spare parts, or to schedule a service appointment, please contact your local Vaillant service center or authorized dealer. Contact details can typically be found on the Vaillant official webtapak atau dalam dokumentasi produk anda.