Ghost Controls AXXV

Ghost Controls Vehicle Sensor (AXXV) Instruction Manual

Model: AXXV | Brand: Ghost Controls

1. Pengenalan

The Ghost Controls AXXV Wired Vehicle Sensor is designed to enhance the functionality of your automatic gate opener system. This sensor detects the presence of a moving vehicle and automatically triggers the gate to open, providing convenient exit from your property without the need for a remote control.

It is compatible with all Ghost Controls gate opener systems and can also work with many other brands that provide 10-16 Volt AC or DC Accessory Power.

2. Produk Lebihview

The AXXV Wired Vehicle Sensor consists of a durable sensor unit and a 55-foot cable designed for underground installation. Its primary function is to detect large metallic objects, such as vehicles, to automate gate operation.

Ghost Controls AXXV Wired Vehicle Sensor with coiled cable

Figure 2.1: Ghost Controls AXXV Wired Vehicle Sensor with its 55-foot cable coiled.

Ghost Controls AXXV Wired Vehicle Sensor with straight cable

Figure 2.2: The AXXV Wired Vehicle Sensor showing the sensor unit and the extended cable.

Ciri-ciri Utama:

3. Persediaan dan Pemasangan

Proper installation is crucial for the optimal performance of your AXXV Wired Vehicle Sensor. Follow these steps carefully.

3.1 Pemasangan Fizikal

  1. Pemilihan Lokasi: Choose a location for the sensor where vehicles will pass directly over it when exiting the property. Ensure the sensor is placed at least 20 feet from the gate itself to allow ample time for the gate to open.
  2. Penggalian: Dig a trench 12-18 inches deep next to your driveway where the sensor will be buried. The trench should extend from the chosen sensor location to your gate opener's control panel.
  3. Peletakan Sensor: Place the sensor unit within the trench. Ensure it is level and securely positioned.
  4. Penghalaan Kabel: Route the 55-foot cable from the sensor unit through the trench to the gate opener's control panel. Ensure the cable is protected from damage during backfilling.
  5. Pengisian semula: Carefully backfill the trench, ensuring the sensor and cable remain at the specified depth.
Ghost Controls AXXV Wired Vehicle Sensor buried in the ground

Figure 3.1: The AXXV Wired Vehicle Sensor installed underground next to a driveway.

Diagram showing wired vehicle sensor placement relative to gate

Figure 3.2: Recommended placement of the wired vehicle sensor, at least 20 feet from the gate.

3.2 Sambungan Elektrik

Connect the sensor's wires to the appropriate terminals on your gate opener's control board. Refer to your gate opener's manual for specific wiring diagrams. The AXXV sensor requires 10-16 Volt AC or DC Accessory Power.

Diagram of Ghost Controls gate accessories including wired vehicle sensor

Gambar 3.3: Lebihview of Ghost Controls accessories, showing the wired vehicle sensor (AXXV) connection point.

4. Arahan Operasi

Once installed and connected, the AXXV Wired Vehicle Sensor operates automatically. When a vehicle passes over the buried sensor, it detects the metallic mass and sends a signal to the gate opener's control board, triggering the gate to open.

This feature provides a hands-free exit solution, eliminating the need to use a remote control or keypad when leaving your property.

Image showing a vehicle approaching a gate with the sensor's detection zone highlighted

Figure 4.1: The vehicle sensor detects approaching vehicles, allowing for automatic gate opening.

5. Penyelenggaraan

The AXXV Wired Vehicle Sensor is designed for minimal maintenance. Since it is buried underground, it is largely protected from environmental elements.

6. Penyelesaian masalah

If your AXXV Wired Vehicle Sensor is not functioning as expected, consider the following troubleshooting steps:

6.1 Sensor Not Triggering Gate

Sensor Recalibration Procedure:

  1. Disconnect both the RED and WHITE wires of the vehicle sensor from the gate opener's control board.
  2. Wait approximately 15 minutes to allow any residual power to drain from the sensor.
  3. Reconnect only the WHITE wire to the control board.
  4. Tunggu lagi 15 minit.
  5. Reconnect the RED wire.
  6. During this entire recalibration process, ensure there are no vehicles or any other large metal objects in the vicinity of the sensor. The sensor should also be placed approximately 20 feet from the fence and buried 10-12 inches into the ground for optimal performance.

6.2 Gate Remaining Open (False Trigger)

7. Spesifikasi

AtributPerincian
Nombor ModelAXXV
JenamaGhost Controls
Dimensi Produk16.25 x 4.5 x 2.75 inci
Berat Barang2.8 paun
Panjang Kabel55 Kaki
Sumber KuasaHardwired Electrical Connection (10-16V AC or DC)
Recommended Burial Depth12-18 inci
Tarikh Mula-mula Tersedia3 Oktober 2016

8. Maklumat Waranti

Ghost Controls products are designed for durability and reliability. For specific warranty details regarding your AXXV Wired Vehicle Sensor, please refer to the warranty documentation included with your gate opener system or visit the official Ghost Controls webtapak.

Generally, Ghost Controls offers a limited lifetime warranty on certain components. Please retain your proof of purchase for warranty claims.

9. Sokongan

For technical assistance, troubleshooting, or any questions regarding your Ghost Controls AXXV Wired Vehicle Sensor, please contact Ghost Controls customer support.

Ikon Sokongan Teknikal

Figure 9.1: Technical Support resources are available online.

Dokumen Berkaitan - AXXV

Praview Sensor Kenderaan Kawalan Hantu dengan Panduan Pemasangan Kabel 55'
Panduan pemasangan komprehensif untuk Sensor Kenderaan Kawalan Hantu dengan Kabel 55' (AXXV-55). Termasuk arahan pendawaian, petua penempatan, amaran keselamatan dan maklumat jaminan untuk sistem pembuka pintu automatik.
Praview Manual Pemasangan dan Pemilik Pembuka Pintu Ghost Controls HDP2
Panduan komprehensif untuk memasang dan mengendalikan sistem pembuka pintu automatik Ghost Controls HDP2 Dual Kit, termasuk keselamatan, persediaan dan penyelesaian masalah.
Praview Pembuka Pintu Automatik Ghost Controls DS1U(M): Manual Pemasangan dan Pemilik
This comprehensive installation and owners manual for the Ghost Controls DS1U(M) Automatic Gate Opener system guides users through proper setup, operation, and safety. Covers pull-to-open and push-to-open installations, power options (solar, AC), troubleshooting, and accessory integration for residential gate automation.
Praview Panduan Pemasangan dan Operasi Sensor Kenderaan Kawalan Hantu
Panduan komprehensif untuk memasang dan mengendalikan Sensor Kenderaan Kawalan Hantu dengan kabel 55', termasuk arahan pendawaian, petua penempatan dan maklumat jaminan.
Praview HANTU KAWALAN Pad Kekunci Tanpa Wayar AXWK: Arahan dan Panduan Pengaturcaraan
Arahan komprehensif untuk Pad Kekunci Tanpa Wayar GHOST CONTROLS AXWK, meliputi pemasangan, persediaan PIN, pengaturcaraan jauh, ciri khas dan penyelesaian masalah.
Praview Arahan Ghost Multi Connect Kit AXMC-R
Arahan untuk memasang dan menggunakan Ghost Multi Connect Kit (AXMC-R) untuk mengawal pintu masuk anda dengan peranti mudah alih melalui aplikasi Remootio.