The CORNING GOSSELIN LC150A-05 Square HDPE Storage Bottle is designed for efficient sampling and storage of various substances. Made from High-Density Polyethylene (HDPE), these bottles offer durability and chemical resistance. Their square design optimizes shelf space, providing 13% to 20% more storage efficiency compared to traditional round bottles. This particular model comes with a 37mm red screw cap and is sterile, ensuring suitability for sensitive applications.

CORNING GOSSELIN LC150A-05 Square HDPE Storage Bottle with red cap

Image: A clear, square-shaped HDPE storage bottle with a red screw cap. The bottle features volume graduations on its side, indicating measurements up to 1.5 liters.

Ciri-ciri Utama

Nota: While other sizes in this bottle series may be graduated, the 150 mL model (LC150A-05) is typically not graduated according to product specifications.

Persediaan dan Penyediaan

  1. Pemeriksaan: Upon receiving the bottles, inspect the packaging and individual bottles for any signs of damage or compromise to sterility. Do not use if the packaging is damaged or the seal is broken.
  2. Storan: Store bottles in a clean, dry environment away from direct sunlight and extreme temperatures.
  3. Pemeriksaan Pra-guna: Before use, ensure the bottle and cap are free from any particulate matter or defects.
  4. Kemandulan: These bottles are supplied sterile. Do not re-sterilize or reuse if sterility is critical for your application, as this may compromise the material integrity or sterility level.

Arahan Operasi

  1. Pengisian: Carefully pour the liquid, semi-liquid, or solid substance into the bottle. The large neck opening facilitates easy filling.
  2. Penutup: Securely screw on the red cap until hand-tight. Avoid overtightening, which can damage the cap or bottle threads.
  3. Storan: Place the filled bottle in the desired storage location. The square design allows for efficient use of space.
  4. Pengendalian: Always handle bottles with care, especially when containing hazardous materials.
  5. Julat Suhu: Ensure the contents and storage environment are within the recommended temperature range for HDPE, typically -80°C to 120°C, though specific application temperatures may vary. Consult material compatibility charts if unsure.

Penyelenggaraan dan Penjagaan

These bottles are designed for single-use applications, especially when sterility is paramount. Therefore, routine maintenance and cleaning for reuse are generally not recommended.

Menyelesaikan masalah

MasalahKemungkinan PuncaPenyelesaian
Leaking from capCap not tightened sufficiently, damaged cap/bottle threads, or incompatible contents.Ensure cap is hand-tight. Inspect cap and bottle threads for damage; replace if necessary. Verify chemical compatibility with HDPE.
Bottle deformation/crackingExposure to extreme temperatures, incompatible chemicals, or physical stress.Ensure contents and storage conditions are within HDPE's temperature and chemical compatibility limits. Avoid dropping or applying excessive pressure. Dispose of damaged bottles.
Sterility compromisedPackaging seal broken, improper handling, or reuse after initial sterile use.Do not use bottles if packaging is compromised. Handle with aseptic technique if maintaining sterility. Do not reuse for sterile applications.

Spesifikasi

AtributPerincian
JenamaCorning / Gosselin
Model ProdukLC150A-05
Nombor Model Item1185L49CS
Bahan BotolPolietilena Ketumpatan Tinggi (HDPE)
Bahan TudungPolipropilena (PP)
Kapasiti150 mL
Saiz Tudung37mm Screw Cap
warnaNatural (bottle), Red (cap)
KemandulanSterile SAL 10-3
Jenis BotolSquare, Disposable
Kuantiti PakejPek 300
Dimensi Pakej3.94 x 3.94 x 3.94 inci (lebih kurang)

Dokumen Berkaitan - 1185L49CS

Praview Manual Pengguna Sistem Corning Everon 6000 MIMO: Konfigurasi, LED dan Spesifikasi RF
Manual pengguna terperinci untuk sistem MIMO siri Everon 6000 Corning Optical Communications. Meliputi konfigurasi 2x2, 2TO1 dan 4TO1 dengan komponen dLRU, DEU, DCU, RIU, BTS, dMRU dan dHRU. Termasuk definisi status LED, versi keluaran dan amaran pendedahan RF kritikal untuk pemasangan profesional.
Praview Manual Pengguna MRU & HRU Corning: Panduan Pemasangan dan Operasi
Manual pengguna ini menyediakan arahan komprehensif untuk pemasangan, konfigurasi dan pengendalian sistem MRU (Unit Jauh Kuasa Sederhana Digital) dan HRU (Unit Jauh Kuasa Tinggi) Corning, komponen penting untuk infrastruktur rangkaian wayarles.
Praview Corning Matribot Bioprinter Instruction Manual
Comprehensive instruction manual for the Corning Matribot Bioprinter, detailing setup, operation, maintenance, and troubleshooting for advanced bioprinting applications in tissue engineering and 3D cell culture.
Praview Everon 6000 G2(3500) Commissioning Instruction Manual
This manual provides detailed instructions for the commissioning and operation of the Everon 6000 G2(3500) system, covering hardware and software requirements, system connection diagrams, configuration procedures, and software upgrade processes.
Praview Corning KS500/KS250 RJ45 Keystone Cat.6A/6 Installation Instructions
Comprehensive installation guide for Corning KS500 and KS250 RJ45 Keystone Jacks (Cat.6A/6, shielded/unshielded). Covers preparation, wiring, assembly, and ordering information.
Praview Corning and Arista 40G, 100G, 400G, and 800G Cabling Reference Guide
A comprehensive guide from Corning Optical Communications detailing cabling scenarios, transceiver types, and part numbers for Arista networks supporting 40G, 100G, 400G, and 800G data rates. Includes local and across-data-center connections.