BWT 812195

BWT Aquameter LF Water Filter Meter 3/8" Instruction Manual

Model: 812195

pengenalan

The BWT Aquameter LF (Low Flow) is designed to precisely monitor the volume of water that has passed through your water filter system. This device helps ensure timely filter replacement, maintaining optimal water quality for applications such as espresso machines. It features an LCD display for real-time capacity tracking and is compatible with various BWT water filters, including Bestmax and Besttaste series.

Produk Selesaiview

BWT Aquameter LF control unit and flow sensor

Rajah 1: BWT Aquameter LF control unit with LCD display and separate flow sensor, connected by a cable. This image shows the main components of the Aquameter LF system.

BWT Aquameter LF product packaging

Rajah 2: The packaging for the BWT Aquameter LF, indicating its 3/8" connection and NSF certification. The packaging also displays the product number 812136 and GTIN 04250266700169.

Persediaan dan Pemasangan

  1. Buka Pembungkusan Komponen: Carefully remove the BWT Aquameter LF control unit, flow sensor, and connecting cable from the packaging.
  2. Identify Flow Direction: The flow sensor has an arrow indicating the direction of water flow. Ensure this aligns with your water line.
  3. Connect Flow Sensor: Install the 3/8" flow sensor into the water line before your BWT water filter. Use appropriate plumbing fittings to ensure a secure, leak-free connection.
    BWT Aquameter LF installed with water filter

    Rajah 3: The BWT Aquameter LF control unit mounted on a wall, connected to a BWT Bestmax water filter installed under a sink. This illustrates a typical installation setup.

  4. Unit Kawalan Sambung: Plug the cable from the flow sensor into the designated port on the BWT Aquameter LF control unit.
  5. Unit Kawalan Gunung: Mount the control unit in a convenient location using the provided mounting hardware. Ensure the display is easily visible.
    Close-up of BWT Aquameter LF control unit installed

    Rajah 4: Satu jarak dekat view of the BWT Aquameter LF control unit mounted, showing the LCD display, "PROG." and "RESET" buttons, and the CE mark. The cable connecting to the flow sensor is visible.

  6. Pengaturcaraan Awal:
    • Press and hold the "PROG." button to enter programming mode.
    • Use the "PROG." button to cycle through settings (e.g., total filter capacity in liters).
    • Use the "RESET" button to adjust the values for each setting.
    • Confirm settings by pressing "PROG." again or waiting for the unit to exit programming mode automatically.
    • Set the filter capacity according to your specific BWT filter model and local water hardness.

Arahan Operasi

Penyelenggaraan

Menyelesaikan masalah

MasalahKemungkinan PuncaPenyelesaian
Paparan kosong atau malap.Bateri rendah atau kehabisan bateri.Contact BWT support for battery replacement.
Capacity not decreasing.Flow sensor incorrectly installed or faulty. No water flow detected.Check flow sensor installation, ensuring correct flow direction. Verify water flow through the system.
Incorrect capacity reading after filter change.Meter not reset after filter replacement.Press and hold the "RESET" button for 3 seconds to reset the meter.
Water leakage at connections.Loose fittings or improper sealing.Ensure all plumbing connections are tight and properly sealed with appropriate thread sealant or tape.

Spesifikasi

Maklumat Waranti

For detailed warranty information regarding your BWT Aquameter LF, please refer to the warranty card included with your product or visit the official BWT webtapak. Terma dan syarat waranti mungkin berbeza mengikut wilayah.

Sokongan

If you require further assistance, technical support, or have questions about your BWT Aquameter LF, please contact BWT customer service or visit the official BWT store online.

Visit the BWT Store on Amazon

Dokumen Berkaitan - 812195

Praview Manual Pemasangan dan Operasi Sistem Penapis Air BWT R1 RSF & HWS
Manual pemasangan, pentauliahan, operasi dan penyelenggaraan yang komprehensif untuk sistem penapis air BWT R1 RSF dan BWT R1 HWS. Termasuk spesifikasi teknikal, penyelesaian masalah dan maklumat keselamatan.
Praview BWT Multi C Point of Entry Manual Pemasangan dan Pengendalian Penapis
Manual ini menyediakan arahan pemasangan dan pengendalian untuk Penapis Masuk BWT Multi C Point, termasuk jenis 1000, 2000, dan 3000. Ia merangkumi skop penghantaran, tujuan penggunaan, fungsi, kegagalan kuasa elektrik, keadaan pemasangan, tetapan kilang, prosedur permulaan, penyelenggaraan, waranti, tanggungjawab operator dan spesifikasi teknikal.
Praview BWT FISPA VAC Manual Pengguna Kolam Renang & Spa Vakum Boleh Dicas semula | Operasi, Penyelenggaraan & Penyelesaian Masalah
Manual pengguna yang komprehensif untuk kolam boleh dicas semula BWT FISPA VAC dan vakum spa. Termasuk persediaan, operasi, penyelenggaraan, amaran keselamatan, penyelesaian masalah dan maklumat waranti.
Praview BWT Multi C Point of Entry Media-Filter Installation and Operating Manual
Comprehensive installation and operating manual for the BWT Multi C Point of Entry Media-Filter, covering safety, installation, operation, maintenance, and troubleshooting for models 1000, 2000, 3000, and 7000. Includes technical specifications and disposal guidelines.
Praview BWT Multipur M Backwash Filter Installation and Operating Manual
This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of the BWT Multipur M backwash filter, covering models DN 65 through DN 150.
Praview BWT pro-soft 11 Arahan Pemasangan dan Operasi
Panduan komprehensif untuk pelembut air BWT pro-soft 11, meliputi pemasangan, operasi, penyelenggaraan dan penyelesaian masalah. Ketahui cara untuk melembutkan bekalan air domestik anda dengan berkesan.