BFT BFT-ICARO-SLIDE-GATE-OPENER-EM

BFT ICARO Slide Gate Opener Instruction Manual

Model: BFT-ICARO-SLIDE-GATE-OPENER-EM

1. Pengenalan

This manual provides essential instructions for the safe installation, operation, and maintenance of your BFT ICARO Slide Gate Opener. The ICARO series is designed for intensive use, offering robust performance and reliability for sliding gates. Please read this manual thoroughly before proceeding with any installation or operation to ensure proper function and to prevent damage or injury.

The BFT ICARO Slide Gate Opener features a monoblock gear motor structure, ensuring maximum resistance and performance in various environmental conditions. It includes proximity limit switches for accurate gate positioning and a control unit with a programming display and D-Track torque, speed, and position management system. An incorporated dual-channel radio receiver simplifies remote control integration.

BFT ICARO Slide Gate Opener main unit

Figure 1: BFT ICARO Slide Gate Opener main unit. This image shows the compact design and robust casing of the gate opener.

2. Maklumat Keselamatan

AMARAN: Failure to follow these safety instructions could result in serious injury or death, and/or damage to the product or property.

  • Installation and repair must be performed by qualified personnel only.
  • Ensure the power supply is disconnected before performing any maintenance or repair work.
  • Keep hands, feet, and clothing clear of the gate and opener while the system is in operation.
  • Jangan benarkan kanak-kanak bermain atau mengendalikan alat kawalan pembuka pintu pagar.
  • Periksa pintu pagar dan pembuka secara berkala untuk tanda-tanda haus, kerosakan atau ketidaksejajaran.
  • Pasang peranti keselamatan seperti fotosel dan tepi keselamatan untuk mengelakkan terperangkap.
  • Ensure the gate moves freely and is properly balanced before installing the opener.

3. Persediaan dan Pemasangan

This section outlines the general steps for installing the BFT ICARO Slide Gate Opener. For detailed diagrams and specific wiring instructions, refer to the separate installation guide provided with your product.

3.1 Penyediaan Tapak

  1. Ensure the gate track is clean and free of obstructions.
  2. Verify the gate slides smoothly by hand and is properly aligned.
  3. Prepare a stable concrete base for mounting the opener unit, ensuring it is level and positioned correctly relative to the gate.

3.2 Memasang Pembuka

  1. Securely fasten the opener unit to the prepared concrete base using appropriate anchor bolts.
  2. Ensure the pinion gear is correctly aligned with the gate's rack, maintaining a small clearance (approx. 1-2 mm) to allow for thermal expansion.

3.3 Sambungan Elektrik

  • Connect the main power supply (230 V, 60 Hz single-phase) to the control unit, ensuring all connections comply with local electrical codes.
  • Wire all safety devices (photocells, safety edges) to the control unit as per the wiring diagram.
  • Connect any accessories such as remote receivers or keypads.

3.4 Pengaturcaraan Awal

  • Power on the unit. The integrated LEO B CBB control panel will display programming options.
  • Follow the on-screen instructions to perform an auto-setup cycle, which will detect the gate's travel limits and adjust motor parameters.
  • Test all safety devices to ensure they function correctly before operating the gate automatically.

4. Arahan Operasi

The BFT ICARO Slide Gate Opener can be operated using various methods, including remote controls, keypads, or other access control systems connected to the integrated dual-channel radio receiver.

4.1 Operasi Automatik

  • Press the designated button on your remote control or keypad to initiate gate movement.
  • The gate will open or close to its programmed limit. A second press during movement will typically stop the gate. A third press will reverse its direction.
  • The D-Track system continuously monitors torque, speed, and position, ensuring smooth and safe operation.

4.2 Keluaran Manual

Sekiranya berlaku gangguan bekalan elektrik atau kerosakan, pintu pagar boleh dikendalikan secara manual.

  1. Locate the manual release knob on the opener unit.
  2. Insert the provided key (if applicable) and turn the knob to disengage the motor.
  3. Pintu pagar kini boleh ditolak atau ditutup dengan tangan.
  4. To re-engage the motor, turn the knob back to its original position and remove the key.

5. Penyelenggaraan

Regular maintenance ensures the longevity and reliable operation of your BFT ICARO Slide Gate Opener. Perform these checks periodically.

5.1 Monthly Checks

  • Pergerakan Pintu: Manually slide the gate to ensure it moves freely without excessive friction or binding.
  • Peralatan keselamatan: Test photocells and other safety sensors by obstructing their path during gate operation. The gate should stop or reverse.
  • Perkakasan Pemasangan: Inspect all mounting bolts and fasteners for tightness.

5.2 Bi-Annual Checks (Recommended by Qualified Technician)

  • Pelinciran: Lubricate the gate wheels, bearings, and any moving parts of the gate itself. The opener's internal gears are typically self-lubricating.
  • Sambungan Elektrik: Inspect all wiring for signs of wear, corrosion, or loose connections.
  • Suis Had: Verify the proper functioning and adjustment of the electromechanical limit switches.
  • D-Track System: A technician can verify the optimal performance of the D-Track torque management system.

Nota: Always disconnect power before performing any maintenance that requires opening the opener's casing.

6. Penyelesaian masalah

This section provides solutions to common issues you might encounter. For more complex problems, contact a qualified technician.

Masalah Kemungkinan Punca Penyelesaian
Pintu gerbang tidak bergerak. No power; Safety device activated; Manual release engaged; Remote battery dead. Check power supply and circuit breaker; Inspect safety sensors for obstructions; Disengage manual release; Replace remote battery.
Pintu pagar berhenti tanpa diduga. Obstruction detected by safety device; Motor overload; Limit switch issue. Clear obstructions; Check gate for free movement; Consult technician for motor or limit switch issues.
Alat kawalan jauh tidak berfungsi. Dead battery; Out of range; Remote not programmed. Replace battery; Move closer to the receiver; Refer to programming instructions for your remote.
Gate opens/closes partially. Limit switches misaligned; Obstruction. Check for obstructions; Re-adjust limit switches (refer to setup section or technician).

7. Spesifikasi Teknikal

Ciri Perincian
Nombor Model BFT-ICARO-SLIDE-GATE-OPENER-EM
Panel Kawalan LEO B CBB (incorporated)
Jenis Operator Tak boleh balik
Bekalan Kuasa 230 V, 60 Hz single-phase
Kuasa Menyerap 1 hp (750 W)
Perlindungan Terma Bersepadu
Pinion Pitch 4 mm (25 gigi)
Leaf Speed 7.9 inci sesaat
Output Rotational Speed 37 rpm
Impact Reaction Electronic clutch with encoder (D-Track)
Suis Had Elektromekanikal
Pelepasan Manual Mechanical release with knob
Kitaran Operasi Penggunaan intensif
Keadaan Persekitaran 5°F hingga 140°F (-15°C hingga 60°C)
Darjah Perlindungan IP24
Berat Operator 56 paun (25.4 kg)
Kekerapan Penggunaan Very intensive

8. Waranti dan Sokongan

8.1 Maklumat Waranti

For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official BFT website. Warranty coverage typically includes defects in materials and workmanship under normal use for a specified period from the date of purchase.

Simpan bukti pembelian anda untuk sebarang tuntutan waranti.

8.2 Sokongan Teknikal

If you encounter issues that cannot be resolved using the troubleshooting guide, or require professional assistance, please contact your authorized BFT dealer or the manufacturer's technical support department.

Pengeluar: BFT

Please have your model number (BFT-ICARO-SLIDE-GATE-OPENER-EM) and purchase date ready when contacting support.

Dokumen Berkaitan - BFT-ICARO-SLIDE-GATE-OPENER-EM

Praview Penggerak BFT ICARO UL untuk Pemasangan dan Manual Pengguna Pintu Gelongsor Rak
Manual pemasangan dan pengguna yang komprehensif untuk penggerak BFT ICARO UL, direka bentuk untuk pintu gelangsar rak. Meliputi garis panduan umum, langkah berjaga-jaga keselamatan, pelepasan manual, spesifikasi teknikal, langkah pemasangan, pendawaian dan penyelesaian masalah.
Praview BFT Mitto 2M/4M Arahan Pengekodan Jauh: Panduan Komprehensif
Ketahui cara memprogram alat kawalan jauh BFT Mitto 2M dan 4M anda untuk pembuka garaj dan pintu pagar. Panduan ini merangkumi pengekodan untuk penerima dengan dan tanpa skrin digital, termasuk amaran keselamatan yang penting.
Praview Manual Pemasangan dan Penggunaan BFT GIOTTO 30-60 S BT / GIOTTO 30-60 BT
Panduan lengkap untuk pemasangan dan penggunaan penghalang automatik BFT GIOTTO 30-60 S BT dan GIOTTO 30-60 BT. Sertakan teknik khusus, konfigurasi dan pengendalian.
Praview BFT MITTO 2B Arahan Pengekodan Jauh | Alat Kawalan Jauh Retro
Panduan langkah demi langkah untuk pengekodan alat kawalan jauh BFT MITTO 2B untuk pembuka pintu pagar, meliputi kaedah skrin LCD jauh dan penerima sedia ada. Termasuk petua penyelesaian masalah.
Praview Panduan Pemasangan Sistem Kawalan Radio BFT CLONIX1-2 & MITTO 2-4 433MHz
Panduan pemasangan komprehensif untuk penerima BFT CLONIX1-2 dan pemancar kawalan radio MITTO 2-4 433MHz, meliputi pengaturcaraan, pengklonan, keselamatan dan spesifikasi teknikal untuk automasi pintu pagar dan pintu.
Praview Pemancar Alat Kawalan Jauh BFT MITTO COOL C4 - Spesifikasi Teknikal dan Keselamatan
Spesifikasi teknikal rasmi, amaran keselamatan dan maklumat pematuhan untuk pemancar alat kawalan jauh BFT MITTO COOL C4, yang beroperasi pada 433.92 MHz. Termasuk maklumat bateri dan pematuhan FCC/Industri Kanada.