Cisa 82750

CISA DGT Vision Electronic Safe 82750 Instruction Manual

Model: 82750 | Brand: CISA

pengenalan

This manual provides essential instructions for the installation, operation, and maintenance of your CISA DGT Vision Electronic Safe, model 82750. Please read this manual thoroughly before using the safe to ensure proper function and security.

Maklumat Keselamatan

Kandungan Pakej

CISA DGT Vision Electronic Safe packaging box

Image: The CISA DGT Vision Electronic Safe as it appears in its packaging box, secured with white straps.

Persediaan dan Pemasangan

The CISA DGT Vision safe is designed for secure installation within furniture or anchored to a wall/floor. Proper installation is crucial for security.

Memilih Lokasi Pemasangan

Anchoring the Safe

The safe features pre-drilled holes for anchoring.

  1. Letakkan peti besi di lokasi yang dikehendaki.
  2. Mark the drilling points through the pre-drilled holes on the back or bottom of the safe onto the mounting surface.
  3. Move the safe and drill appropriate holes in the marked positions.
  4. Insert suitable anchors (not always included, check package contents) into the drilled holes.
  5. Reposition the safe and secure it using the provided or appropriate screws. Tighten all screws firmly.
Dalaman view of the CISA DGT Vision Electronic Safe showing pre-drilled mounting holes

Imej: Dalaman view of the CISA DGT Vision Electronic Safe, showing the pre-drilled holes on the back and bottom for secure mounting.

Diagram showing dimensions of the CISA DGT Vision Electronic Safe

Image: Technical diagram illustrating the external dimensions of the CISA DGT Vision Electronic Safe: 420mm (width) x 300mm (height) x 350mm (depth).

Arahan Operasi

Initial Battery Installation

The electronic keypad requires 1.5V alkaline button cell batteries.

  1. Cari petak bateri, biasanya di bahagian dalam pintu selamat.
  2. Masukkan bateri, pastikan polariti yang betul.
  3. Tutup penutup petak bateri.
Close-up of the CISA DGT Vision electronic keypad

Imej: A terperinci view of the CISA DGT Vision electronic keypad, featuring numerical buttons and function keys.

Membuka Peti besi buat Kali Pertama

Upon initial setup, the safe typically has a factory-set default code (e.g., "1234" or "0000"). Refer to the specific instructions provided with your safe for the exact default code.

  1. Enter the default code on the keypad.
  2. Press the confirmation button (often marked with a key or checkmark symbol).
  3. The lock will disengage, and you can open the door.
Hand interacting with the CISA DGT Vision electronic keypad

Image: A hand pressing buttons on the CISA DGT Vision electronic keypad, demonstrating user interaction.

Setting/Changing Your Personal Code

It is highly recommended to change the default code immediately after the first opening.

  1. With the safe door open, locate the internal reset button (often a small button on the inside of the door or near the battery compartment).
  2. Press the reset button. The keypad will usually emit a beep or light up to indicate it's ready for a new code.
  3. Enter your new personal code (typically 4-8 digits).
  4. Tekan butang pengesahan.
  5. Re-enter your new personal code and press the confirmation button again to confirm.
  6. Uji kod baharu dengan pintu terbuka sebelum menutupnya.

Menutup dan Mengunci Peti besi

To lock the safe, simply close the door. The locking bolts will automatically engage.

Close-up of the CISA DGT Vision safe's locking bolts

Imej: Dari dekat view of the robust nickel-plated steel locking bolts of the CISA DGT Vision safe, extended from the door edge.

Penyelenggaraan

Penggantian Bateri

The keypad features indicator lights to warn of low battery power. Replace batteries promptly when this warning appears to avoid being locked out.

  1. Open the safe using your code.
  2. Cari petak bateri di bahagian dalam pintu.
  3. Tanggalkan bateri lama dan buang dengan bertanggungjawab.
  4. Insert new 1.5V alkaline button cell batteries, observing correct polarity.
  5. Tutup petak bateri.

External Emergency Power

If batteries completely drain and you cannot open the safe, use the external emergency power cable.

  1. Locate the external power input port on the keypad (often a small socket).
  2. Connect the emergency power cable to this port and to a fresh 9V battery (not included).
  3. While holding the emergency power, enter your code to open the safe.
  4. Replace the internal batteries immediately after opening.

Penjagaan Am

Menyelesaikan masalah

Safe Does Not Open with Code

Pad kekunci Tidak Bertindak balas

Safe Door Does Not Close Properly

Spesifikasi

CiriPerincian
Model82750
JenamaCISA
Dimensi (L x H x P)420 mm x 300 mm x 350 mm
Berat badan17.55 kg (38.7 lbs)
bahanKeluli Aloi
Jenis KunciPapan kekunci elektronik
Sumber Kuasa1.5V Alkaline Button Cell Batteries (internal), 9V Battery (external emergency)
warnaAntrasit

Waranti dan Sokongan

For warranty information and technical support, please refer to the documentation provided at the time of purchase or contact CISA customer service directly. Keep your purchase receipt as proof of purchase.

For further assistance, visit the official CISA webtapak atau hubungi pusat perkhidmatan mereka yang dibenarkan.

Dokumen Berkaitan - 82750

Praview CISA Mito Sensor: Installation and User Manual
Comprehensive guide for the CISA Mito Sensor lock, detailing installation, operation, maintenance, safety, and troubleshooting. Includes technical specifications and accessories.
Praview CISA Push Microswitch Installation Guide - Model 06A95060
Official installation instructions for the CISA Push Microswitch (Model 06A95060), a component for panic exit devices. Includes steps for securing to bracket and checking operation.
Praview CISA Touch Microswitch Installation Guide
Official installation instructions for the CISA Touch Microswitch (Art. 06A95050), detailing arm bracket dismantling, microswitch assembly, and operational checks.
Praview Guida all'Installazione CISA: Comandi Esterni per Maniglioni Antipanico (Art. 07A78.xx)
Istruzioni dettagliate per l'installazione dei comandi esterni CISA per maniglioni antipanico, modello Art. 07A78.xx. Include configurazioni, montaggio e specifiche tecniche.
Praview CISA Electric Strikes Cover Installation Guide
Instruction sheet for CISA electric strikes covers (Art. 06A98120.XX), detailing installation configurations and mounting procedures for various door edge types. Includes guidance on selecting appropriate plates and screws.
Praview CISA 06A98910 Adapter for Fast Access Devices Retrofit - Installation Guide
This document provides installation instructions for the CISA 06A98910 Adapter for Fast Access Devices Retrofit. It covers assembly, cutting specifications, and final checks for various door configurations.