pengenalan
This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Champion Power Equipment 100165 9375/7500-Watt Dual Fuel Portable Generator. This generator is designed for versatility and convenience, capable of operating on either gasoline or propane. It features an electric start, Cold Start Technology for reliable starting in cold weather, and an Intelligauge to monitor key operational parameters.

Imej: The Champion Power Equipment 100165 Dual Fuel Portable Generator, showcasinreka bentuk dan panel kawalannya yang teguh.
Maklumat Keselamatan
Always operate the generator outdoors in a well-ventilated area, far from windows, doors, and vents. Carbon monoxide is a colorless, odorless gas that can be fatal. Never operate the generator indoors, in a garage, or in any enclosed space. Ensure proper grounding of the generator before operation to prevent electrical shock.
For more tips on portable generator safety, visit TakeYourGeneratorOutside.com.
Persediaan
1. Membongkar dan Memasang
Carefully remove the generator from its packaging. Attach the wheels and the foldaway U-shaped handle as per the instructions in the included assembly guide. The never-flat tires and handle facilitate easy transport.
2. Menambah Minyak
The unit includes 1.2-quarts of 10W-30 oil. Locate the oil fill cap/dipstick, remove it, and carefully pour the oil into the engine. Do not overfill. The generator is equipped with a low oil shut-off sensor to protect the engine.
3. Pengisian
Your dual-fuel generator can operate on either gasoline or propane. Ensure the generator is off and cooled before adding fuel.
- petrol: Isi tangki bahan api 6.1 gelen dengan petrol tanpa plumbum yang baharu. Jangan isi secara berlebihan.
- Propana: Connect the included 3.3-foot propane hose with a built-in regulator to a 20-pound propane tank and to the generator's propane inlet.

Image: The generator positioned with a gasoline can and a propane tank, illustrating its dual-fuel capability.
4. Sambungan Bateri
For electric start functionality, ensure the included battery is properly connected. Refer to the detailed instructions in your owner's manual for correct battery connection procedures.
Arahan Operasi
1. Memulakan Penjana
The generator features a convenient electric start with Cold Start Technology for quick starts in cold weather. A manual pull start is also available as a backup.
- Permulaan Elektrik: Ensure the fuel selector is set to the desired fuel type (gasoline or propane). Turn the engine switch to the 'ON' position. Press and hold the electric start button until the engine starts.
- Permulaan Manual: If the electric start battery is low or for manual preference, use the pull cord.
2. Pemilihan Bahan Api
Use the patented fuel selector switch to easily switch between gasoline and propane. This allows for safe transitions between fuel sources during operation.

Image: Close-up of the generator's control panel highlighting the dual-fuel selector switch.
3. Memantau Output Kuasa
The Intelligauge allows you to easily monitor power output and track maintenance intervals. It displays voltage, hertz dan jam masa jalan.

Imej: Terperinci view of the generator's control panel, showing the Intelligauge display and various outlets.
4. Connecting Loads
The generator provides multiple outlets for various power needs:
- Satu soket pengunci 120V 30A (L5-30R)
- Satu soket pengunci 120/240V 30A (L14-30R)
- Empat soket isi rumah yang dilindungi GFCI 120V 20A (5-20R)
The Volt Guard built-in surge protector prevents overloads and keeps your equipment safe.

Image: The generator in use at a construction site, powering various tools.
5. Mematikan
To shut down the generator, first disconnect all loads. Allow the generator to run for a few minutes without load to cool down. Then, turn the engine switch to the 'OFF' position.
Penyelenggaraan
Regular maintenance is crucial for the longevity and optimal performance of your generator. Always refer to your owner's manual for a detailed maintenance schedule.
- Perubahan Minyak: Tukar minyak enjin selepas 5 jam pertama operasi, kemudian setiap 50 jam atau setiap tahun selepas itu.
- Penapis Udara: Periksa dan bersihkan penapis udara dengan kerap. Gantikan jika rosak.
- Palam Pencucuh: Periksa dan bersihkan palam pencucuh secara berkala. Gantikan jika haus.
- Storan: For long-term storage, ensure the fuel tank is empty (run until dry for gasoline) and the battery switch is turned off to prevent drain.
Menyelesaikan masalah
If your generator encounters issues, consult the troubleshooting section of your comprehensive owner's manual. Common issues may include starting difficulties, power output problems, or unusual noises. Always ensure proper fuel levels, oil levels, and clean air filters before troubleshooting.
Spesifikasi
| Ciri | Spesifikasi |
|---|---|
| Jenama | ChampPeralatan Kuasa ion |
| Nama Model | 9375/7500-Watt Dual Fuel Portable Generator |
| Memulakan Wattage (Petrol) | 9375 Watt |
| Lari Wattage (Petrol) | 7500 Watt |
| Memulakan Wattage (Propana) | 8400 Watt |
| Lari Wattage (Propana) | 6750 Watt |
| Jenis Bahan Api | Petrol, Propana (LPG) |
| Jenis Enjin | 4 Lejang, 439cc |
| Isipadu Tangki | 6.1 gelen |
| Masa Jalan (Petrol, beban 50%) | 8 jam |
| Run Time (Propane, 50% load) | 5.5 hours (with 20-pound tank) |
| Tahap Kebisingan | 74 dBA (dari ketinggian 23 kaki) |
| Outlet | 1x 120V 30A (L5-30R), 1x 120/240V 30A (L14-30R), 4x 120V 20A GFCI (5-20R) |
| Dimensi (L x W x H) | 28.7" x 27.8" x 26.4" |
| Berat Barang | 202.4 paun |

Imej: Penjana dengan dimensi utamanya (panjang, lebar, tinggi) yang ditunjukkan.
Waranti dan Sokongan
Champion Power Equipment 100165 generator comes with a 3-year limited warranty. Additionally, you receive FREE lifetime technical support from dedicated experts. For assistance, please contact ChampSokongan ion.