pengenalan
The Elitech WJL-6000S is a highly sensitive halogen refrigerant gas leak detector designed for HVAC systems. It is capable of detecting all halogenated refrigerants, including HFCs, CFCs, HCFCs, and blends such as R22, R134A, R404A, R410A, and R1234YF. This manual provides detailed instructions for the proper setup, operation, and maintenance of your leak detector to ensure accurate and reliable performance.
Figure 1: Elitech WJL-6000S Freon Leak Detector with flexible probe.
Persediaan
1. Pemasangan Bateri
The WJL-6000S requires four AAA Lithium Metal batteries (not included). To install the batteries:
- Locate the battery compartment on the back of the detector.
- Luncurkan buka penutup bateri.
- Insert four AAA batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
- Tutup penutup bateri dengan selamat.
Rajah 2: Petak bateri untuk bateri AAA.
2. Penghidupan dan Penentukuran Awal
Before first use, or after prolonged storage, allow the detector to warm up and self-calibrate in a clean, refrigerant-free environment.
- Turn the sensitivity knob from 'off' to 'on'. The detector will begin a warm-up sequence.
- The warm-up time is approximately 6 seconds. The unit will beep to indicate it is ready for use.
- Ensure the probe tip is in an area free of refrigerants during this calibration phase to ensure accurate readings.
Video 1: Demonstrates the beeping sound of the WJL-6000 leak detector when it detects a leakage, also shows initial power on and calibration.
Arahan Operasi
1. Melaraskan Sensitiviti
The WJL-6000S features 7 adjustable sensitivity levels. Turn the knob to select the appropriate sensitivity for your detection needs. Higher sensitivity levels (e.g., 7) are for detecting very small leaks, while lower levels (e.g., 1) are for larger leaks or to avoid false positives in contaminated areas.
Figure 3: Sensitivity adjustment knob.
2. Leak Detection Process
Once calibrated, slowly move the flexible probe tip around suspected leak areas. The detector responds within 3 seconds to the presence of halogenated refrigerants.
- Penunjuk Boleh Didengar: The ticking sound will increase in frequency and turn into a sharp siren in the presence of a refrigerant leak.
- Penunjuk Visual: The LED indicator lights will flash increasingly as the concentration of refrigerant increases.
- Probe Fleksibel: The 7.9-inch flexible probe allows for easy access to difficult and hard-to-reach areas.
Figure 4: Detector showing audible and visual alarms during operation.
3. Refrigerant Types Detected
The WJL-6000S is designed to detect a wide range of halogenated refrigerants, including:
- HFCs: R134A, R404A, R410A, R1234YF, R407C, R417A, R507, R23, R508A, R508B, R152a, R32, etc.
- HCFCs: R22, R123, R124, R141b, R142b, R402A, R402B, R408A, R409A, etc.
- CFC: R11, R12, R13, R502, R503, etc.
- PFCs: PFC-14, PFC-116, PFC-218, etc.
- HFO: R-1234YF
Figure 5: Comprehensive list of detectable refrigerants.
4. UV Light Functionality
The detector includes a UV light feature, useful for identifying leaks when a fluorescent agent has been added to the refrigerant system. It also functions as a white flashlight for illuminating dark and small spaces.
Figure 6: UV light and white flashlight capabilities.
Penyelenggaraan
1. Cleaning the Sensor Tip
To ensure optimal performance and prevent false alarms, keep the sensor tip clean and free from contaminants such as compressor oil, dirt, moisture, or other solvents. Avoid touching the sensor tip with bare hands.
2. Penggantian Bateri
When the battery indicator shows low power, replace all four AAA batteries following the installation steps in the Setup section.
Menyelesaikan masalah
1. False Alarms or Inconsistent Readings
- Bahan cemar: Ensure the sensor tip is clean and not in contact with any liquids, oils, or dirt.
- Penentukuran semula: If the ticking tone becomes inconsistent or you suspect false readings, move the detector to a clean, fresh air environment and allow it to recalibrate. Adjust the sensitivity knob to a suitable degree.
- Halangan aliran udara: Avoid pressing the probe tip directly against surfaces that might block airflow to the sensor, as this can cause false alarms.
2. No Detection
- Pemeriksaan Bateri: Verify that the batteries are correctly installed and have sufficient charge. Replace if necessary.
- Tetapan Sensitiviti: Ensure the sensitivity is set to an appropriate level for the expected leak size. For very small leaks, use the highest sensitivity setting.
- Penempatan Probe: Ensure the probe is moved slowly and methodically around the suspected leak area to allow the sensor sufficient time to detect the refrigerant.
Spesifikasi
| Ciri | Perincian |
|---|---|
| Jenama | Elitech |
| Model | WJL-6000S |
| Sumber Kuasa | 4 AAA Lithium Metal batteries (not included) |
| Kepekaan Maks | 0.21 oz/yr |
| Masa Prapemanasan | 6 saat |
| Masa Tindak Balas | 3 saat |
| Suhu Bekerja | 0°C hingga 52°C (32°F hingga 125.6°F) |
| Kelembapan Operasi | 95% RH (tidak pemeluwapan) |
| Panjang Probe | 7.9 inches (flexible) |
| Berat Barang | 7.2 auns |
| Dimensi Produk | 1.37"D x 1.37"W x 5.9"H |
| Penggera | Audible, Visual |
Figure 7: Detailed specifications and dimensions of the detector.
Waranti & Sokongan