TASER 22149

TASER X2 Pro Series Replacement Cartridges User Manual

Brand: TASER | Model: X2 Pro Series Replacement Cartridges (Part No. 22149)

pengenalan

This user manual provides essential information for the safe and effective use of TASER X2 Pro Series Replacement Cartridges. These cartridges are designed specifically for use with TASER X2 devices, ensuring continued protection and operational readiness. It is crucial to read and understand all instructions before handling or installing the cartridges.

Produk Selesaiview

The TASER X2 Pro Series Replacement Cartridges are vital components for your TASER X2 device, enabling its primary function as a conducted electrical weapon. Each cartridge contains compressed nitrogen to propel two probes up to 15 feet, delivering an incapacitating electrical pulse. The cartridges are designed for quick and easy replacement, ensuring minimal downtime for your device.

Single TASER X2 Pro Series Replacement Cartridge

Image: A single TASER X2 Pro Series Replacement Cartridge, showing its black and yellow casing and the probe deployment area.

Two TASER X2 Pro Series Replacement Cartridges

Image: Two TASER X2 Pro Series Replacement Cartridges, shown side-by-side, highlighting their compact design.

Persediaan dan Pemasangan

Proper installation of the replacement cartridges is critical for the safe and effective operation of your TASER X2 device. Always ensure the device is disarmed and pointed in a safe direction before handling cartridges.

  1. Pastikan Keselamatan: Verify your TASER X2 device is in the "SAFE" position and the safety switch is engaged.
  2. Remove Used Cartridge: Press the cartridge release button (if applicable) or firmly pull the used cartridge straight out from the front of the device. Dispose of used cartridges according to local regulations.
  3. Inspect New Cartridge: Before installation, visually inspect the new cartridge for any damage or defects. Ensure the protective blast doors are intact.
  4. Masukkan Kartrij Baharu: Align the new cartridge with the cartridge bay on the front of your TASER X2 device. Push the cartridge firmly into the bay until it clicks securely into place. Do not force the cartridge.
  5. Sahkan Pemasangan: Gently tug on the cartridge to ensure it is seated properly and does not wobble. The device should now be ready for use once the safety is disengaged.
TASER X2 Cartridges with clear protective covers

Image: Two TASER X2 Pro Series Replacement Cartridges with clear protective covers over the probes, indicating they are new and ready for installation.

Arahan Operasi

These cartridges are designed to be used with TASER X2 devices. Refer to your TASER X2 device's primary user manual for complete operating instructions. The following outlines the general use of the cartridges:

  1. Bertujuan: Point the TASER X2 device at the target, ensuring a clear line of sight. The 15-foot range allows for a safe distance.
  2. Kerahan: Disengage the safety and press the trigger. The cartridge will deploy two probes, which attach to the target and deliver an electrical pulse.
  3. Susulan: After deployment, assess the situation. If the threat is neutralized, re-engage the safety and secure the device. If necessary, a second cartridge can be deployed if your X2 device is equipped with two bays.

For a better understanding of TASER technology and its benefits, please watch the following informational video:

Video: "The Taser Difference | Explore the Future of Personal Safety". This video explains the core benefits and operational principles of TASER devices, including the safety distance provided by cartridges.

Penyelenggaraan dan Penyimpanan

To ensure the longevity and reliability of your TASER X2 Pro Series Replacement Cartridges, follow these maintenance and storage guidelines:

Menyelesaikan masalah

If you encounter issues with your TASER X2 Pro Series Replacement Cartridges, consider the following:

MasalahKemungkinan PuncaPenyelesaian
Cartridge does not seat properly.Salah jajaran atau halangan.Ensure proper alignment and clear any debris from the cartridge bay. Push firmly until it clicks.
Prob tidak berfungsi.Expired cartridge, faulty cartridge, or device issue.Check cartridge expiration date. Replace with a new, unexpired cartridge. If issue persists, consult your TASER X2 device manual or contact TASER support.
Device indicates cartridge error.Improperly seated cartridge or internal device error.Remove and re-insert the cartridge. If the error persists, try a different cartridge. If the problem continues, refer to your TASER X2 device manual.

Spesifikasi

CiriPerincian
Nama ProdukTASER X2 Pro Series Replacement Cartridges
Nombor Model22149
KeserasianTASER X2 Devices
Julat15 kaki (4.5 meter)
Kuantiti2-Pek
Dimensi (L x W x H)5.67 x 4.13 x 1.22 inci
Berat badan0.11 Kilogram
warnaHitam/Kuning
bahanOther (as per manufacturer)
PengeluarAxon Enterprises, Inc.

Waranti dan Sokongan

These TASER X2 Pro Series Replacement Cartridges come with a Waranti 1 tahun from the manufacturer, Axon Enterprises, Inc. For warranty claims, technical support, or further inquiries, please refer to the contact information provided with your TASER X2 device or visit the official TASER webtapak.

Untuk maklumat dan sumber tambahan, anda boleh melawati TASER Store on Amazon.

Dokumen Berkaitan - 22149

Praview Panduan Penggantian Bateri HD TASER CAM
Arahan langkah demi langkah dan garis panduan keselamatan untuk menggantikan bateri dalam peranti TASER CAM HD. Termasuk bahagian yang diperlukan dan langkah berjaga-jaga pengendalian.
Praview Manual Pemasangan Dok Senjata TASER | Axon Enterprise
Manual pemasangan ini menyediakan arahan komprehensif untuk menyediakan dan mengkonfigurasi Dok Senjata TASER, yang membolehkan muat naik data yang selamat dan pengecasan semula bateri untuk peranti TASER 7 dan TASER 10 ke Axon Evidence.
Praview TASER Energieapparat: Waarschuwingen en Arahan untuk Wetshandhaving
Maklumat penting, waarschuwingen en instructions voor het gebruik van TASER-energieapparate door wetshandhavingsinstanties, met nadruk op risicobeheer and correct gebruik.
Praview Peranti Tenaga Mudah Alih TASER: Amaran dan Arahan Polis
Maklumat keselamatan dan kesihatan, amaran dan arahan penting untuk peranti tenaga mudah alih TASER untuk penguatkuasaan undang-undang. Meliputi risiko, penggunaan, penyelenggaraan dan langkah berjaga-jaga.
Praview Amaran dan Maklumat Penguatkuasaan Undang-undang Senjata Tenaga Pegang Tangan TASER
Dokumen ini menyediakan amaran keselamatan yang penting, arahan dan maklumat untuk penguatkuasaan undang-undang penggunaan peranti tenaga pegang tangan TASER. Ia meliputi risiko, penggunaan yang betul, penyelenggaraan, dan potensi bahaya untuk meminimumkan bahaya kepada pengguna dan subjek.
Praview Amaran dan Arahan Peranti Kawalan Elektronik TASER untuk Penguatkuasaan Undang-undang
Amaran keselamatan yang komprehensif, arahan dan maklumat untuk penggunaan peranti kawalan elektronik TASER oleh kakitangan penguatkuasa undang-undang. Meliputi potensi risiko, prosedur operasi yang selamat dan penyelenggaraan.