1. Pengenalan
This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of your Evergreen Genteq X-13 Furnace Blower Motor. Please read this manual thoroughly before attempting any installation or operation. Retain this manual for future reference.
2. Maklumat Keselamatan
WARNING: Risk of Electric Shock and Injury.
- Always disconnect power to the furnace or air handler before installing, servicing, or removing the motor. Failure to do so can result in severe personal injury or death.
- Pemasangan dan servis hanya boleh dilakukan oleh juruteknik HVAC yang berkelayakan atau juruelektrik berlesen.
- Pastikan semua sambungan pendawaian selamat dan mematuhi kod elektrik tempatan.
- Do not operate the motor if it is damaged or if any electrical components are exposed.
- Pakai peralatan pelindung diri (PPE) yang sesuai, termasuk cermin mata dan sarung tangan keselamatan, semasa pemasangan dan penyelenggaraan.
- Jauhkan tangan dan pakaian longgar daripada bahagian yang bergerak semasa operasi.
3. Kandungan Pakej
Sahkan bahawa semua komponen ada dan tidak rosak semasa membongkar. Jika ada barang yang hilang atau rosak, hubungi pembekal anda dengan segera.
- Evergreen Genteq X-13 Furnace Blower Motor (Model: CECOMINOD085195)

Image of the Evergreen Genteq X-13 Furnace Blower Motor, showing its compact design and electrical connections.
4. Persediaan dan Pemasangan
This motor is designed as a replacement for existing X-13 type furnace blower motors. Professional installation is highly recommended.
4.1 Pemeriksaan Pra-Pemasangan
- Ensure the replacement motor specifications (voltage, horsepower, frame size) match the original motor. This motor is 3/4 HP, 230 Volt.
- Periksa motor untuk sebarang kerosakan yang boleh dilihat yang mungkin berlaku semasa penghantaran.
- Gather necessary tools: screwdrivers, wire strippers, multimeter, safety glasses, gloves.
4.2 Langkah Pemasangan
- Putuskan Kuasa: Locate the main power switch for your furnace or air handler and turn it OFF. Verify power is off using a multimeter.
- Akses Petak Peniup: Open the access panel to the blower compartment of your furnace or air handler.
- Putuskan Sambungan Pendawaian: Carefully disconnect the electrical wiring from the old motor. Note the position and color of each wire for correct re-connection. Take photos if necessary.
- Keluarkan Motor Lama: Unmount and remove the old blower motor. This may involve removing mounting bolts or clamps.
- Pasang Motor Baru: Position the new Evergreen Genteq X-13 motor in the blower housing. Secure it using the original mounting hardware. Ensure the motor is firmly seated and aligned.
- Sambungan Pendawaian: Reconnect the electrical wiring to the new motor, matching the connections noted from the old motor. Ensure all connections are tight and secure. Refer to the wiring diagram on the motor label if available.
- Tutup Petak: Tutup dan selamatkan panel akses petak blower.
- Pulihkan Kuasa: Turn the main power switch for the furnace or air handler back ON.
5. Arahan Operasi
The Evergreen Genteq X-13 Furnace Blower Motor operates automatically in conjunction with your furnace or air conditioning system's control board. Once properly installed and powered, the motor will engage and disengage as required by the system's thermostat and operational cycles.
- Permulaan permulaan: After installation and power restoration, initiate a heating or cooling cycle from your thermostat to test the motor's operation.
- Operasi Biasa: The motor should run smoothly with minimal noise. Airflow should be consistent through your ductwork.
- Operasi tidak normal: If you observe unusual noises, vibrations, or lack of airflow, immediately shut off power to the unit and refer to the Troubleshooting section.
6. Penyelenggaraan
The Evergreen Genteq X-13 Furnace Blower Motor is designed for long-term, maintenance-free operation. It features permanently lubricated bearings and does not require periodic oiling.
- Pemeriksaan Tahunan: It is recommended to have a qualified technician inspect the motor and blower assembly annually as part of routine HVAC system maintenance.
- Pembersihan: Ensure the blower wheel and motor exterior remain free of dust and debris. Accumulation of dirt can reduce efficiency and lead to overheating. Always disconnect power before cleaning. Use a soft brush or vacuum cleaner to remove dust. Do not use liquids directly on the motor.
- Penapis Udara: Regularly check and replace your furnace's air filter. A clogged filter can restrict airflow, causing the blower motor to work harder and potentially overheat.
7. Penyelesaian masalah
Before performing any troubleshooting steps, ensure power to the unit is disconnected.
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Motor tidak hidup | Tiada bekalan kuasa Pendawaian yang salah Papan kawalan yang rosak | Check circuit breaker and power switch. Verify wiring connections against diagram. Rujuk juruteknik yang berkelayakan. |
| Motor makes unusual noise or vibrates | Pemasangan longgar Serpihan dalam roda peniup Bearing motor rosak | Ketatkan bolt pemasangan. Inspect and clean blower wheel. Consult a qualified technician for motor replacement. |
| Motor terlalu panas dan mati | Restricted airflow (clogged filter) Lebihan beban Pengudaraan yang tidak mencukupi | Gantikan penapis udara. Pastikan voltage dan beban. Ensure blower compartment is clear. |
| Aliran udara lemah atau tiada | Penapis udara tersumbat Blower wheel obstruction Motor running slowly | Gantikan penapis udara. Inspect and clean blower wheel. Rujuk juruteknik yang berkelayakan. |
If troubleshooting steps do not resolve the issue, or if you are unsure about any procedure, contact a qualified HVAC service professional.
8. Spesifikasi
- Jenama: malar hijau
- Pengeluar: Genteq
- Nombor Model: CECOMINOD085195
- Kuasa kuda: 0.75 HP (3/4 HP)
- Voltage: 230 Volt
- Bahan: Tembaga
- Dimensi Produk: 9 x 9 x 17 inci
- ASIN: B00STPY9MS
- Tarikh Mula-mula Tersedia: 27 Januari 2015
9. Waranti dan Sokongan
For warranty information and technical support, please refer to the documentation provided at the point of purchase or contact the manufacturer directly. Keep your purchase receipt as proof of purchase for warranty claims.