Remco 5517-1E1-82B

Manual Pengguna Pam Permintaan Remco 5.3 GPM

Model: 5517-1E1-82B

1. Pengenalan

The Remco 5500 series 5.3 GPM Demand Pump (Model: 5517-1E1-82B) is a professional-grade solution designed for performance and efficiency in various applications, particularly agricultural spray applications. This pump features a 60 PSI pressure setting and a sealed 12-volt electric motor, engineered to operate reliably even in harsh environments.

Constructed with durable components, the 5500 Series pump is built to withstand long and continuous duty cycles. Its materials are compatible with common agricultural chemicals, including herbicides, fertilizers, and insecticides. This manual provides essential information for the safe and effective setup, operation, and maintenance of your Remco pump.

Ciri-ciri Utama:

  • Professional Grade Quality
  • 5.3 GPM (20.06 LPM) flow rate, 60 PSI (4.1 Bar) on Demand
  • Made In the U.S.A.
  • 6" length 14 AWG wire leads with SAE 2 pin connector
  • Highest flow rate and lowest operating temperature at spray pressures
  • Chemically compatible with common Agricultural chemicals
  • 100% Factory Tested
  • Completely Sealed Motor
  • Low Heat and Power Consumption
  • Superior Vertical Priming
Remco 5.3 GPM Demand Pump, side view

Figure 1: Remco 5.3 GPM Demand Pump (Model 5517-1E1-82B)

2. Maklumat Keselamatan

Always read and understand all instructions before operating the pump. Failure to follow safety guidelines can result in injury or damage to the equipment.

  • Ensure the power source is disconnected before performing any maintenance or installation.
  • Wear appropriate personal protective equipment (PPE) when handling chemicals or operating the pump.
  • Do not exceed the maximum liquid temperature of 140°F (60°C).
  • For optimal performance and motor life, ensure the motor surface temperature does not exceed 150°F (66°C). The motor is not equipped with thermal protection.
  • Verify chemical compatibility before use to prevent damage to the pump components.
  • Keep the pump away from flammable materials and open flames.
  • Pastikan pengudaraan yang betul semasa operasi.

3. Persediaan dan Pemasangan

Proper installation is crucial for the optimal performance and longevity of your Remco pump. Follow these steps carefully:

3.1 Memasang Pam

  • Mount the pump in a secure, dry location, protected from direct weather exposure.
  • Ensure adequate space around the pump for ventilation and access for maintenance.
  • The pump can self-prime up to 14 feet (4.0 m) vertically. Position it as close as possible to the fluid source for best results.

3.2 Sambungan Elektrik

  • The pump operates on 12 VDC. Connect the 14 AWG wire leads (6" or 12" 2-Pin Mold / Custom Connection) to a suitable 12-volt power source.
  • Ensure correct polarity: Red wire is positive (+), Black wire is negative (-).
  • Use appropriate fusing for the electrical circuit to protect the pump and power supply.
Close-up of the pump's wire leads with SAE 2-pin connector

Figure 2: SAE 2-pin connector on the pump's wire leads

3.3 Fluid Connections

  • The pump features 3/4" Quick Attach Ports for fluid connections.
  • Connect the inlet port to your fluid supply and the outlet port to your application system.
  • Pastikan semua sambungan selamat dan bebas bocor.
Remco 5.3 GPM Demand Pump with dimensions labeled

Figure 3: Pump dimensions for installation planning

4. Arahan Operasi

The Remco 5.3 GPM Demand Pump operates in a demand mode, meaning it will run when there is a demand for fluid and shut off when the demand ceases or pressure is reached.

4.1 Permulaan Permulaan

  1. Ensure all fluid connections are tight and the pump is securely mounted.
  2. Verify the fluid source is open and available to the pump.
  3. Connect the pump to the 12 VDC power supply. The pump may run briefly to prime itself.
  4. Open the discharge valve or nozzle to allow fluid to flow. The pump will start automatically.
  5. Once the system is primed and air is purged, the pump will operate smoothly.

4.2 Chemical Application

This pump is designed for use with various agricultural chemicals, including herbicides, fertilizers, and insecticides. Always ensure the chemicals used are compatible with Viton valves and Santoprene diaphragms to prevent damage.

  • Refer to the chemical manufacturer's guidelines for proper mixing ratios and application rates.
  • Avoid running the pump dry for extended periods, as this can cause damage. The pump has dry run capability for short durations.

5. Penyelenggaraan

Regular maintenance will extend the life and ensure the reliable operation of your Remco pump.

5.1 Post-Use Cleaning

  • After every use, especially when pumping chemicals, it is highly recommended to rinse the pump thoroughly with clean water.
  • Run clean water through the pump for several minutes to flush out any residual chemicals.

5.2 Pengurusan Suhu

  • The maximum liquid temperature is 140°F (60°C).
  • The maximum motor temperature is 180°F (82°C). However, for user safety, optimal performance, and maximum motor life, the motor surface temperature should not exceed 150°F (66°C).
  • Monitor the pump's temperature during prolonged operation. If it becomes excessively hot, allow it to cool down.

5.3 Penyimpanan

  • If storing the pump for an extended period, ensure it is thoroughly cleaned and drained of all liquids.
  • Store in a dry, frost-free environment.

6. Penyelesaian masalah

This section provides solutions to common issues you might encounter with your Remco pump. If the problem persists, contact customer support.

MasalahKemungkinan PuncaPenyelesaian
Pam tidak berjalanNo power; Loose electrical connection; Blown fuse; Motor failureCheck power supply; Secure connections; Replace fuse; Contact support
Aliran atau tekanan rendahClogged inlet/outlet; Air leak in suction line; Worn diaphragm/valves; Low voltageClear obstructions; Check for leaks; Inspect/replace components; Verify voltage
Pam berjalan secara berterusanLeak in system; Pressure switch malfunction; Air in systemCheck for leaks; Contact support; Bleed air from system
Kebisingan yang berlebihanAir in system; Loose mounting; Debris in pumpBleed air; Secure mounting; Inspect and clean pump

7. Spesifikasi Teknikal

AtributPerincian
JenamaRemco
Nombor Model5517-1E1-82B
taipPam diafragma 5 ruang
ModPermintaan
Voltage12 VDC
Kadar Aliran Maksimum5.3 GPM (20.06 LPM)
Penetapan Tekanan60 PSI (4.1 Bar)
Fluid Port3/4" Quick Attach Ports
InjapViton
DiafragmaSantoprene
Dawai Lead14 AWG - 6" OR 12" 2-Pin Mold / Custom Connection
Mementingkan DiriUp to 14' (4.0 m) vertically
Kitaran TugasSelang-seli
Dry Run Capabilityya
Suhu Cecair Maks140°F (60°C)
Max Motor Temperature180°F (82°C) (Recommended max 150°F / 66°C for optimal life)
Dimensi Produk10.8"L x 5.3"W x 6"H
Berat Barang7.96 paun

8. Waranti dan Sokongan

For warranty information, technical support, or replacement parts, please contact Remco customer service. Keep your purchase receipt and model number handy when contacting support.

For more information, visit the official Remco webtapak atau hubungi talian sokongan pelanggan mereka.

Dokumen Berkaitan - 5517-1E1-82B

Praview Katalog Produk Pam Gred Profesional REMCO
Katalog komprehensif pam diafragma gred profesional REMCO, termasuk siri seperti 3300, 3200, 5500, Zeus, SmoothFlo, RollMax dan PowerRV, berserta aksesori dan penyelesaian pam tersuai.
Praview Pam Remco 5500 Series: Garis Panduan Operasi dan Pemasangan
Garis panduan operasi dan pemasangan yang komprehensif untuk pam Remco Siri 5500, meliputi langkah berjaga-jaga keselamatan, pemasangan, paip, sambungan elektrik, prosedur pemasangan, servis, penyelesaian masalah dan alat ganti.
Praview Pam REMCO Economy Plus 2200 2400: Manual Operasi & Pemasangan
Garis panduan operasi dan pemasangan yang komprehensif, spesifikasi, dimensi dan penyelesaian masalah untuk pam siri REMCO Economy Plus 2200 dan 2400. Termasuk senarai alat ganti dan maklumat waranti untuk pam industri yang berpatutan dan berkualiti tinggi ini.
Praview REMCO Accumulator/Pulsation Dampener Tank Installation & Maintenance Manual
Detailed installation, maintenance, troubleshooting, and warranty information for the REMCO RACT820-NPT and RACT820-JG Accumulator/Pulsation Dampener Tanks. Learn how to optimize pump performance and system longevity.
Praview Remco STAR 4 dan 1: Univerzalni Daljinski Upravljač - Uputstvo dan Kodovi
Anda boleh melihat laman web ini dan koristite daripada Remco STAR 4 dan 1 univerzalni daljinski upravljač. Jangan lupa untuk menggunakan kodova, fungsi dan penyelesaian masalah pada TV, STB, SAT, DVD dan BD.
Praview Remco RollMax R440, R660, R880 Series: Operational and Installation Guidelines
Comprehensive operational and installation guidelines for Remco RollMax R440, R660, and R880 series roller pumps. Covers intended use, materials, specifications, installation, operation, troubleshooting, and warranty information.