HACH 2893300

Manual Pengguna Set Piawaian Gel Sekunder Hach SpecCheck

Model: 2893300 | Brand: HACH

1. Pengenalan

The Hach 2893300 SpecCheck Secondary Gel Standards Set, DPD Chlorine - HR, is designed for the instrument performance verification of Hach colorimeters and spectrophotometers. These stable and convenient gel standards provide a reliable method to check the accuracy and calibration of your analytical instruments for DPD Chlorine measurements.

Hach SpecCheck Secondary Gel Standards Set with packaging box and four vials

An image showing the Hach SpecCheck Secondary Gel Standards Set. The set includes a white and blue cardboard box labeled 'SPEC/COLOR STANDARD DPD-CHLORINE-HR SECONDARY STANDARDS KIT' and four small glass vials. Three vials contain a pink gel, labeled 'DPD-CHLORINE HR STD 1', 'STD 2', and 'STD 3'. The fourth vial contains a clear or white gel, likely a blank or zero standard. The box also displays the Hach Company logo and contact information.

2. Persediaan

  1. Membuka kotak: Carefully remove the standards set from its packaging.

  2. Pemeriksaan: Inspect all vials for any signs of damage or leakage. Do not use if damage is observed.

  3. Initial Storage: Store the kit in an upright position at a temperature between 10°C and 25°C (50°F and 77°F) to maintain stability and accuracy. Avoid exposure to direct sunlight or extreme temperatures.

3. Arahan Operasi

These standards are intended for instrument verification purposes only and should not be used for direct sampanalisis.

  1. Prepare Instrument: Ensure your Hach colorimeter or spectrophotometer is clean and properly warmed up according to its own operating manual.

  2. Prepare Standards: Gently invert each standard vial several times to ensure homogeneity before use. Do not shake vigorously, as this may introduce air bubbles.

  3. Zero Instrument: Insert the blank or zero standard (typically the clear vial) into the instrument's sample compartment and zero the instrument as per its instructions.

  4. Measure Standards: Insert the DPD Chlorine HR standards (pink vials) one by one into the instrument. Record the readings for each standard.

  5. Verify Readings: Compare the instrument readings with the expected values provided with your specific instrument or in the kit documentation. Significant deviations indicate a need for instrument calibration or service.

  6. Storan Selepas Penggunaan: After use, return the standards to their original packaging and store them upright under the recommended conditions.

4. Penyelenggaraan

  • Pembersihan: Wipe the exterior of the vials with a soft, lint-free cloth if necessary. Do not use abrasive cleaners or solvents, as these may damage the vial or affect the gel.

  • Pengendalian: Handle vials carefully to prevent breakage. Avoid touching the optical surfaces of the vials that will be inserted into the instrument to prevent fingerprints or smudges that could affect readings.

  • Storan: Always store the standards in their original packaging, upright, and within the specified temperature range (10°C - 25°C) to preserve their integrity and extend their shelf life. Ensure the caps are securely tightened.

5. Penyelesaian masalah

  • Bacaan Tidak Tepat: If instrument readings deviate significantly from expected values, ensure the standards are stored correctly and are within their expiration date. Verify that the instrument is clean, properly warmed up, and calibrated. Check for any air bubbles or particulate matter within the gel standards.

  • Standards Appear Degraded: If the gel appears cloudy, discolored, or shows signs of separation, the standards may be compromised and should be replaced. Ensure proper storage conditions were consistently maintained.

6. Spesifikasi

AtributPerincian
Nombor Model Item2893300
PengeluarSYARIKAT HACH
Tarikh Mula-mula Tersedia28 Ogos 2014
ASINB00N40EFR2

7. Waranti dan Sokongan

For technical assistance, product support, or information regarding the limited warranty for your Hach SpecCheck Secondary Gel Standards Set, please contact Hach Company directly. Refer to the contact details provided on the product packaging or visit the official Hach webtapak untuk maklumat sokongan terkini.

Dokumen Berkaitan - 2893300

Praview Penganalisis Klorin Kolorimetrik Julat Ultra Rendah CL17sc Hach: Teknikal Lebih Lanjutview
Komprehensif berakhirview of the Hach Ultra Low Range CL17sc online colorimetric chlorine analyser. Details its applications in water quality monitoring, technical specifications, principle of operation, dimensions, and ordering information for industrial and utility use.
Praview Arahan Kit Ujian Klorin Hach: Panduan Ringkas untuk Pengujian Kualiti Air
Panduan ringkas ini menyediakan arahan untuk menggunakan Kit Ujian Klorin Hach bagi mengukur paras klorin bebas atau jumlah keseluruhan dalam air. Ia merangkumi langkah penyediaan, prosedur terperinci dan notis penting untuk ujian kualiti air yang tepat.
Praview Cara Memprogram Semula Hach DR-3000 untuk Vial COD Accu-TEST
Arahan dan perkhidmatan untuk memprogram semula spektrofotometer atau kolorimeter Hach DR-3000 untuk menggunakan vial accu-TEST COD Bioscience, Inc. Termasuk sokongan dan butiran perkhidmatan pemprograman semula daripada Bioscience, Inc.
Praview AS950 Controller Operations Manual - HACH
Comprehensive operations manual for the HACH AS950 Controller, detailing setup, configuration, operation, calibration, and troubleshooting for AWRS, refrigerated, and portable samplers.
Praview Piawaian ABS Hach DR/Check™: Maklumat Am dan Arahan Kawalan Kualiti
Panduan komprehensif untuk Piawaian ABS Hach DR/Check™, yang memperincikan maklumat umum, penyimpanan, prosedur penjajaran dan arahan kawalan kualiti langkah demi langkah untuk digunakan dengan spektrofotometer DR/800 dan Odyssey.
Praview Manual Pengguna Penganalisis HACH CL17sc - Pengukuran Kepekatan Klorin
Manual pengguna untuk penganalisis HACH CL17sc, yang memperincikan spesifikasi, pemasangan, operasi, penyelenggaraan dan penyelesaian masalah untuk mengukur kepekatan klorin total dalam air. Bersambung dengan Pengawal SC.