FAS MDR-U

FAS Linear MDR-U Single Channel Plug-in Receiver Instruction Manual

1. Pengenalan

The FAS Linear MDR-U Single Channel Plug-in Receiver is designed to enable compatibility between nearly any garage door or gate operator and Linear's MegaCode format transmitters. This versatile receiver offers a straightforward plug-in design and a simple two-conductor wired connection for integration into existing systems. It features a learning mode capable of storing up to 10 unique transmitter codes.

2. Maklumat Keselamatan

3. Kandungan Pakej

4. Persediaan dan Pemasangan

The MDR-U receiver is designed for simple installation. Follow these steps to integrate it with your garage door or gate operator:

  1. Pemutusan Kuasa: Before beginning, ensure the power to your garage door or gate operator is completely disconnected.
  2. Pemasangan: Plug the receiver directly into a standard 110 VAC outlet near your garage door or gate operator.
  3. Sambungan Pendawaian: Locate the two-conductor wire terminals on the receiver. Connect these terminals to the appropriate input terminals on your garage door or gate operator that are designed for external control devices (e.g., wall button terminals). Refer to your operator's manual for specific wiring instructions.
  4. Sambungan Selamat: Ensure all wire connections are tight and secure to prevent intermittent operation.
  5. Pemulihan Kuasa: Once all connections are made and secured, restore power to the garage door or gate operator.
FAS Linear MDR-U Single Channel Plug-in Receiver

This image displays the FAS Linear MDR-U Single Channel Plug-in Receiver. The device features a compact gray housing with a standard two-prong electrical plug for power. On one side, there are screw terminals for connecting the two-conductor wire to the garage door or gate operator. A small red 'LEARN' button is visible on the opposite side, used for programming transmitters. The product label with specifications and certifications is also visible.

5. Arahan Operasi

Once the receiver is installed and programmed with your MegaCode transmitters, simply press the button on your programmed transmitter. The receiver will activate its normally open contact for 0.5 seconds, signaling the garage door or gate operator to open or close, or to stop, depending on its current state and programming.

6. Programming (Learning Mode)

The MDR-U receiver can store up to 10 unique MegaCode transmitter codes. To program a transmitter:

  1. Locate the LEARN Button: Identify the small red 'LEARN' button on the side of the receiver unit (refer to the product image for location).
  2. Masukkan Mod Pembelajaran: Press and release the 'LEARN' button. The receiver will enter learning mode, typically indicated by an LED light (if present) or a specific operational state.
  3. Kod Penghantaran: Within approximately 10 seconds of pressing the 'LEARN' button, press the button on your MegaCode transmitter that you wish to program.
  4. Pengesahan: The receiver should provide a confirmation (e.g., a flash of an LED, a click, or a brief activation of the connected operator) indicating successful programming.
  5. Operasi Ujian: Test the newly programmed transmitter to ensure it operates the garage door or gate operator correctly.
  6. Program Additional Transmitters: Repeat the process for any additional transmitters, up to the maximum capacity of 10.

7. Penyelesaian masalah

8. Spesifikasi

Nombor ModelMDR-U
JenamaFAS
Input Kuasa110 VAC +/- 10%, 60 Hz
Dimensi (D x W x H)1.61" x 2.52" x 1.61"
Transmitter Capacity10 MegaCode Transmitters
Pengaktifan KeluaranNormally open contact, 0.5 seconds
Teknologi KetersambunganCordoned (Wired)
Peranti SerasiGarage Door Operators, Gate Operators
PengeluarLINEAR RESEARCH

9. Waranti dan Sokongan

For warranty information or technical support, please refer to the documentation provided with your purchase or contact the manufacturer, LINEAR RESEARCH, directly. Keep your proof of purchase for warranty claims.

Dokumen Berkaitan - MDR-U

Praview Pneumatic Solenoid Valves and Valve Islands - Product Catalog
Comprehensive catalog detailing pneumatic solenoid valves, including M8 and M12 connectors, various valve functions (2x3/2, 5/3), and advanced valve island configurations with IO-Link and fieldbus interfaces. Features technical specifications, ordering data, and accessories for industrial automation applications.
Praview FAS FNI IOL-711-006-M12 PT100 Analog Input Module User Manual
User manual for the FAS FNI IOL-711-006-M12 module, detailing its features, interface definitions, IO-Link data, safety instructions, and troubleshooting for PT100 analog input applications.
Praview FAS FNI IOL-310-S01-K024 Arahan Penggunaan Modul IO-Link
Arahan pengguna untuk modul FAS FNI IOL-310-S01-K024 IO-Link, memperincikan ciri, antara muka, pengendalian data, keselamatan dan spesifikasinya untuk sambungan rangkaian industri.
Praview FAS FNI PNT-507-105-M IO-Link Module User Manual
Comprehensive user manual for the FAS FNI PNT-507-105-M IO-Link module, covering safety, installation, technical specifications, integration with Profinet and IIoT (MQTT/OPCUA), and ordering information.
Praview FAS FNI IOL-760-004-E066 IO-Link Slave Module User Manual and Technical Guide
Comprehensive user manual for the FAS FNI IOL-760-004-E066 IO-Link Slave Module, detailing its features, installation, interface specifications (RS485, IO-Link), communication parameters, and process data handling for industrial automation applications.
Praview Modul, Kabel dan Penyambung IO-Link Automasi Industri FAS
Katalog komprehensif modul FAS IO-Link, kabel Ethernet industri dan penyambung. Menampilkan Profinet, Ethernet/IP, EtherCAT dan CC-Link IE Asas keserasian dengan penyambung M12, M8, RJ45 dan SUB-D untuk automasi industri yang mantap.