Watts WATTS - 118946

Watts 0342691 Manual Pengguna Injap Pelega Tekanan 30 PSI

Model: WATTS - 118946

pengenalan

This manual provides essential information for the proper installation, operation, and maintenance of the Watts Series 335 ASME rated Boiler Pressure Relief Valve. This valve is designed for hydronic systems, specifically for boilers up to 510,000 BTU at a 30 PSI (2.11 bar) set point. Its compact, all-bronze construction makes it suitable for various OEM boiler applications.

Watts 30 PSI Pressure Relief Valve, front view

Rajah 1: Depan view of the Watts 30 PSI Pressure Relief Valve, showing the bronze body and the pressure relief lever.

Maklumat Keselamatan

Always follow local codes and regulations during installation and maintenance. Ensure the system is depressurized and cooled before attempting any work on the valve. Wear appropriate personal protective equipment (PPE).

Persediaan dan Pemasangan

The Watts 0342691 Pressure Relief Valve is designed for straightforward installation. It features a 3/4-inch female threaded inlet and a 3/4-inch FNPT outlet.

  1. Penyediaan: Ensure the boiler system is completely shut down, depressurized, and cooled. Drain any water from the system if necessary.
  2. Tanggalkan Injap Lama (jika berkenaan): Carefully unthread the existing pressure relief valve from the boiler.
  3. Sapukan Pengedap Benang: Apply an appropriate thread sealant (e.g., PTFE tape or pipe dope) to the male threads of the new Watts valve.
  4. Pasang Injap Baharu: Thread the new valve into the boiler's pressure relief valve port. Tighten securely with a wrench, ensuring not to overtighten.
  5. Connect Discharge Piping: Attach appropriate discharge piping to the valve's outlet. This piping must be sized correctly and routed to a safe discharge point, preventing scalding or property damage.
  6. Penekanan Semula Sistem: Slowly re-pressurize the boiler system and check for any leaks around the newly installed valve and connections.
Watts 30 PSI Pressure Relief Valve, side view

Rajah 2: Sisi view of the Watts 30 PSI Pressure Relief Valve, showing the compact design and connection points.

Prinsip Operasi

The Watts 0342691 is an automatic pressure relief valve designed to protect hydronic heating systems from over-pressurization. It is factory-set to open at 30 PSI (Pounds per Square Inch). When the system pressure exceeds this set point, the valve will automatically open, discharging water to relieve the excess pressure and prevent damage to the boiler or system components. Once the pressure drops below the set point, the valve will automatically close.

The valve also features a manual test lever. This lever allows for periodic manual testing of the valve's operation. When the lever is lifted, the valve will open, discharging water. It is important to exercise caution when using the test lever, as hot water may be discharged.

Penyelenggaraan

Regular maintenance ensures the longevity and proper function of your pressure relief valve.

Menyelesaikan masalah

MasalahKemungkinan PuncaPenyelesaian
Valve constantly dripping or leaking
  • Tekanan sistem terlalu tinggi
  • Sediment or debris under the seat
  • Worn or damaged internal components
  • Improper installation (e.g., insufficient thread sealant)
  • Check system pressure; ensure it is below 30 PSI.
  • Briefly lift the test lever to flush out debris.
  • If leaking persists, the valve may need replacement.
  • Re-install with proper thread sealant if leak is from threads.
Valve does not open when pressure is high
  • Valve seized due to corrosion or lack of use
  • Incorrect valve installed (wrong pressure setting)
  • Attempt to operate the manual test lever.
  • If it remains seized, the valve must be replaced immediately to prevent system damage.
  • Verify the valve's pressure rating matches system requirements.

Spesifikasi

Watts 30 PSI Pressure Relief Valve with dimensions shown against a hand

Figure 3: The Watts 30 PSI Pressure Relief Valve demonstrating its compact size, approximately 2.9 inches (7 cm) in height.

AtributNilai
Nombor ModelWATTS - 118946
bahanGangsa
Saiz Sambungan Masuk3/4 Inci
Jenis Sambungan MasukFemale Threaded
Saiz Sambungan Outlet3/4 Inci
Jenis Sambungan OutletFNPT
Tekanan Operasi Maksimum30 PSI (2.11 bar)
Penarafan BTUSehingga 510,000 BTU
Bilangan Pelabuhan2
Dimensi (L x W x H)3 x 2.3 x 1.8 inci
Berat badan0.01 ounces (Note: This seems unusually low, likely a data entry error in source. Actual weight for such a valve would be higher.)
Spesifikasi MetASME Section IV

Maklumat Waranti

Specific warranty details for this product are not provided in this manual. Please refer to the manufacturer's official website or contact Watts customer service for current warranty terms and conditions.

Sokongan dan Hubungan

For technical assistance, replacement parts, or further information, please contact Watts customer support or visit their official webtapak.

Watts Official Webtapak: www.watts.com

Watts Store on Amazon: Visit the Watts Store

Dokumen Berkaitan - WATTS - 118946

Praview Watts Pressure Reducing Valve with Hydraulic Check Feature - Stainless Series
Teknikal tamatview of the Watts ACV Combination Pressure Reducing and Check Valve, detailing its operation, installation guidelines, and a list of related control valve models.
Praview Watts W-M115 ACV Pressure Reducing Valve: Specification & Installation Guide
Comprehensive guide detailing the specifications, dimensions, flow rates, operating principles, installation, and start-up procedures for the Watts W-M115 ACV Pressure Reducing Valve. Essential information for industrial and commercial applications.
Praview Watts BMS Flood Sensor Retrofit Connection Kit Installation Guide
This guide provides detailed installation instructions for the Watts BMS Flood Sensor Retrofit Connection Kit (Model IS-RFK-FS-ReliefValve-BMS). It covers kit components, requirements, preparation, installation steps, wiring diagrams, and warranty information for monitoring relief valve discharge lines.
Praview Siri Teknik Spesifikasi Watt SL100XL, L100XL, LL100XL, LLL100XL
Teknik-teknik spesifikasi lengkap tuangkan les soupapes de décharge température and pression à tige allongée Watts series SL100XL, L100XL, LL100XL dan LLL100XL. Butiran sur les ciri-ciri, dimensi, pemasangan et sécurité pour chauffe-eau.
Praview Installation, Operation, and Maintenance Manual for Watts LFM115-74/LFM6115-74 Pressure Reducing Control Valves
Comprehensive guide for the installation, operation, maintenance, and troubleshooting of Watts LFM115-74 and LFM6115-74 Pressure Reducing Control Valves with Low Flow By-Pass. Includes detailed instructions, diagrams, and maintenance schedules.
Praview Panduan Pemasangan dan Penyelenggaraan Injap Pengurang Tekanan Air Siri Watts LFN45B
Panduan komprehensif untuk memasang, menyelenggara dan menyelesaikan masalah injap pengurang tekanan air Watts LFN45B Series. Termasuk amaran keselamatan, prosedur pelarasan dan maklumat waranti.