1. Produk Lebihview
The HENDI 271346 Roasting Thermometer/Timer is a versatile kitchen tool designed to accurately monitor temperatures during cooking, especially for roasting. It features a durable stainless steel probe suitable for oven use and includes a timer function for precise cooking control.

Image: The HENDI 271346 digital thermometer and timer unit with its attached stainless steel probe, ready for use.
Ciri-ciri Utama:
- Fungsi Pemasa: Allows for precise timing of cooking processes.
- Julat Suhu Luas: Berukuran dari 0°C hingga 300°C (32°F hingga 572°F).
- Unit Boleh Dipilih: Tukar dengan mudah antara Celsius (°C) dan Fahrenheit (°F).
- Accurate Graduation: Provides readings with 1°C (or 0.1°C resolution as per specifications) precision.
- Mod Kunci: For continuous temperature monitoring.
- Min/Max Temperature Function: Records the lowest and highest temperatures measured.
- Programmable Temperature Alarm: Memberi amaran kepada anda apabila suhu sasaran dicapai.
- Kuar Tahan Lama: 150 mm stainless steel probe designed to remain in the oven (heat resistant).
- Dikendalikan Bateri: Convenient and portable, battery included.
2. Maklumat Keselamatan
Please read all safety instructions carefully before using the device. Improper use can lead to damage or injury.
- Pengendalian Probe: The stainless steel probe is sharp. Handle with care to avoid injury.
- Unit Utama: The main thermometer unit is NOT waterproof. Do not immerse it in water or other liquids. Clean with a damp kain sahaja.
- Probe Heat Resistance: The probe and its cable are designed to withstand high oven temperatures (up to 250°C). However, avoid direct flame contact.
- Kanak-kanak: Jauhkan peranti daripada capaian kanak-kanak.
- Keselamatan Bateri: Ensure correct battery polarity. Remove batteries if the device will not be used for an extended period. Dispose of batteries responsibly.
- Penggunaan yang Dimaksudkan: This device is intended for food temperature measurement only. Do not use for other purposes.
3. Kandungan Pakej
Selepas membuka bungkusan, pastikan semua item berikut ada:
- HENDI 271346 Thermometer/Timer Unit
- 150 mm Stainless Steel Temperature Probe
- Bateri (dipasang terlebih dahulu atau disertakan secara berasingan)

Image: All components of the HENDI 271346 thermometer, including the main unit, probe, and a probe clip/holder.
4. Persediaan
- Pemasangan Bateri:
Locate the battery compartment on the back of the main unit. Open the cover, insert the included battery (typically AAA) ensuring correct polarity (+/-), and close the compartment securely.
- Sambungan Probe:
Insert the probe's jack firmly into the designated port on the side of the main unit. Ensure a secure connection for accurate readings.
- Kuasa Awal Hidup:
Press the power button (if available, otherwise it may power on automatically upon probe connection or battery insertion). The display should light up, showing the current ambient temperature.
5. Arahan Operasi
5.1. Pengukuran Suhu
- Penempatan Probe: Insert the stainless steel probe into the thickest part of the food, avoiding bones or gristle, for the most accurate temperature reading.
- Suhu Pemantauan: The current temperature will be displayed on the main unit's screen.
- Using in Oven: The probe and its cable are oven-safe. Ensure the main unit remains outside the oven, away from direct heat.

Image: The HENDI 271346 thermometer in use, with the probe inserted into a piece of meat to monitor its internal temperature.
5.2. Setting Temperature Units (°C/°F)
Press the "°C/°F S/S" button to toggle between Celsius and Fahrenheit temperature displays.
5.3. Setting a Target Temperature (Alarm)
- Press the "SET TEMP" button (or similar, based on common thermometer interfaces, assuming it's the same as the °C/°F button or a dedicated one if present).
- Use the "MIN" and "SEC" buttons (or up/down arrows if present) to adjust the desired target temperature.
- Once the target temperature is set, the alarm will sound when the probe reaches this temperature.
5.4. Menggunakan Fungsi Pemasa
The device also functions as a timer.
- Press the "MODE" button (if available, or a long press on "S/S" might switch modes) to enter timer mode.
- Use the "MIN" and "SEC" buttons to set the desired countdown time.
- Press the "S/S" button to start or stop the timer. An alarm will sound when the timer reaches zero.
5.5. Min/Max Temperature Function
Fungsi ini membolehkan anda view the minimum and maximum temperatures recorded since the device was powered on or reset.
- Press a dedicated "MIN/MAX" button (if available) or cycle through modes to view nilai-nilai ini.
- To reset the min/max values, consult the device's specific button combination (often a long press on the min/max button or power cycle).
5.6. Mod Kunci
The lock mode is designed to monitor temperature continuously without accidental changes to settings.
- Activate lock mode by pressing the designated "LOCK" button (if available) or a specific button combination.
- In lock mode, the display will continue to show the current temperature, but buttons will be unresponsive until unlocked.
6. Penyelenggaraan
Proper maintenance ensures the longevity and accuracy of your HENDI thermometer.
- Membersihkan Probe: After each use, clean the stainless steel probe thoroughly with warm soapy water. Rinse and dry completely. The probe can be wiped with a damp kain.
- Membersihkan Unit Utama: Lap unit utama dengan lembut, damp cloth. Do NOT immerse the main unit in water or place it under running water. Avoid abrasive cleaners or solvents.
- Storan: Store the thermometer and probe in a clean, dry place when not in use. Keep the probe tip protected to prevent damage.
- Penggantian Bateri: When the display dims or the device stops functioning, replace the battery. Follow the battery installation steps in Section 4.1.
7. Penyelesaian masalah
| Masalah | Kemungkinan Punca | Penyelesaian |
|---|---|---|
| Paparan kosong atau malap. | Bateri lemah atau mati. Pemasangan bateri yang salah. | Replace the battery. Ensure battery is inserted with correct polarity. |
| Inaccurate temperature readings (e.g., showing +50°C initially). | Probe not fully inserted. Probe or cable damage. Environmental interference. | Ensure the probe jack is fully seated. Check probe and cable for visible damage. Try testing in a known temperature environment (e.g., ice water for 0°C). If the issue persists, the probe or unit may be faulty. |
| Penggera tidak berbunyi. | Alarm volume too low or muted. Target temperature not set correctly. | Check if there's a volume setting (unlikely for this type of device, but check manual if available). Re-set the target temperature. |
| Butang tidak bertindak balas. | Device is in Lock Mode. Battery issue. | Deactivate Lock Mode. Replace battery. |
8. Spesifikasi
| Ciri | Perincian |
|---|---|
| Nombor Model | 271346 |
| Jenama | HENDI |
| Julat Suhu | 0°C hingga 300°C (32°F hingga 572°F) |
| Resolusi Suhu | 0.1°C |
| Panjang Probe | 150 mm |
| Bahan Probe | Keluli Tahan Karat |
| Main Unit Material | Keluli Tahan Karat (luaran) |
| Dimensi (L x W x H) | 2.6 x 11.9 x 23.1 cm (approx. 65x70x17 mm for the unit itself) |
| Berat badan | 118 gram |
| Sumber Kuasa | Battery Powered (Battery included) |
| Heat Resistance (Probe) | Up to 250°C (Oven-safe) |
| Negara Asal | China |
9. Waranti dan Sokongan
For warranty information, please refer to the documentation included with your purchase or visit the official HENDI website. HENDI provides high-quality products and exceptional service.
If you encounter any issues not covered in this manual or require further assistance, please contact HENDI customer support through their official channels. Always provide your product model number (271346) when seeking support.
You can find more information about HENDI products and support at: www.hendi.eu